6ED1 052-1CC01-0BA6 SIEMENS, 6ED1 052-1CC01-0BA6 Datasheet - Page 104

no-image

6ED1 052-1CC01-0BA6

Manufacturer Part Number
6ED1 052-1CC01-0BA6
Description
MODULE, LOGO! 24
Manufacturer
SIEMENS
Datasheet

Specifications of 6ED1 052-1CC01-0BA6

No. Of Analogue Inputs
2
No. Of Digital Inputs
8
No. Of Digital Outputs
4
Meter Display Type
LCD
Ip/nema Rating
IP20
Approval Bodies
CSA, FM, IEC, UL, VDE
Approval Category
External Depth
External Depth
55mm
External Length / Height
90mm
6
Control systems
C7-636 Touch
Technical specifications (continued)
Output ranges, voltage
Output ranges, current
Actuator connection
Burden resistance (in the nominal
output range)
Dest. limit against voltages and
currents applied from outside
Analog value formation
Integration and conversion
time/triggering per channel
Settling time
Sensor
Connectable encoders
- 0 to 10 V
- -10 to +10 V
- 0 to 20 mA
- -20 to +20 mA
- 4 to 20 mA
- for voltage output
- for voltage output
- for current output
- at voltage outputs, min.
- at voltage outputs,
- at current outputs, max.
- at current outputs,
- Voltages at the outputs against
- Current (DC), max.
- with over-range (bits incl. sign),
- Integration time
- Permissible input frequency,
- Conversion time (per channel)
- Response time of the input filter
- Basic execution time of the
- for resistive load
- for capacitive load
- for inductive load
- 2-wire BEROS
- permissible closed-circuit
6/12
2-wire connection
4-wire connection
2-wire connection
capacitive load, max.
inductive load, max.
M
max
parameterizable
max.
module (all channels enabled)
current (2-wire BEROS), max.
ANA
SIMATIC C7
Siemens ST 70 News · 2006
6ES7 636-2EB00-0AE3
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
1 k
0.1 µF
300
0.1 mH
16 V
50 mA
12 Bit
Yes
400 Hz
1 ms
0.38 ms
1 ms
0.6 ms
1 ms
0.5 ms
Yes
1.5 mA
Error/accuracies
Operational limit in the entire
temperature range
Basic error limit (operational limit
at 25 °C)
Interference voltage suppression for
f = n x (fl +/- 1 %)
Integral functions
• Number of counters
• Count frequency (counters) max.
• Frequency sensor
• Frequency measurement
• Number of frequency sensors
• Controlled positioning
• Integrated function blocks
• PID controller
• Pulse outputs
• Number of pulse outputs
• Cut-off frequency (pulse)
Status information/ interrupts/
diagnostics
Interrupts
- relative to the output range,
- relative to the output range,
- relative to the input range,
- relative to the input range,
- relative to the input range,
- relative to the output range,
- relative to the output range,
- relative to the input range,
- relative to the input range,
- relative to the input range,
- relative to the input range,
- Series-mode interference
- Common-mode interference,
(control)
- Interrupts
voltage
current
voltage
current
resistance
voltage
current
voltage
current
resistance
resistance thermometer
(peak value of interference <
rated value
min.
6ES7 636-2EB00-0AE3
+/- 1 %
+/- 1 %
+/- 1 %
+/- 1 %
+/- 5 %
+/- 0.7 %
+/- 0.7 %
+/- 0.7 %
+/- 0.7 %
+/- 3 %
+/- 3 %
30 dB
40 dB
4
60 kHz
Yes
Yes
4
Yes
Yes
Yes
Yes
4
2.5 kHz
Yes

Related parts for 6ED1 052-1CC01-0BA6