6ED1 052-1CC01-0BA6 SIEMENS, 6ED1 052-1CC01-0BA6 Datasheet - Page 75

no-image

6ED1 052-1CC01-0BA6

Manufacturer Part Number
6ED1 052-1CC01-0BA6
Description
MODULE, LOGO! 24
Manufacturer
SIEMENS
Datasheet

Specifications of 6ED1 052-1CC01-0BA6

No. Of Analogue Inputs
2
No. Of Digital Inputs
8
No. Of Digital Outputs
4
Meter Display Type
LCD
Ip/nema Rating
IP20
Approval Bodies
CSA, FM, IEC, UL, VDE
Approval Category
External Depth
External Depth
55mm
External Length / Height
90mm
Overview
Technical specifications
Transmission rate
Interfaces
• 10BaseT, 100BaseTX
• Connection for power supply
Power supply
Current consumption
• From backplane bus
• From 24 V DC external
Power loss
Perm. ambient conditions
• Operating temperature
• Transport/storage temperature
• Relative humidity
Construction
• Module format
• Dimensions (W x H x D) in mm
• Weight
Configuring software
Performance data
S5-compatible communication
(SEND/RECEIVE)
• Sum of all simultaneously operable
• Useful data
TCP/UDP connections
- TCP
- UDP
CP 343-1
10/100 Mbit/s autosensing
RJ45
2-pin plug-in terminal strip
+5 V DC ( 5%) and
+24 V DC ( 5%)
200 mA
typ. 160 mA
max. 200 mA
5.8 W
0 °C to +60 °C
-40 °C to +70 °C
Max. 95% at +25 °C
Compact module S7-300,
double width
80 x 125 x 120
Approx. 600 g
STEP 7 V5.3 SP2 and higher
Max. 16
8 KB
2 KB
• Connection of SIMATIC S7-300 to Industrial Ethernet
• Communication services:
• Multicast for UDP
• IP address assignment via DHCP, simple PC tool or via the
• Access protection by means of configurable access list
• Remote programming and initial startup via the network
• Automatic setting of the CPU clock via Ethernet with NTP or
• SNMP MIB2 diagnostics information for network management
S7 communication
• Number of connections
PG/OP communication
• Number of operable OP connec-
Multi-protocol operation
• Sum of all simultaneously
Multicast
PROFINET communication
PN IO-Controller
• Number of operable
• Size of IO data areas overall
• Size of I/O data areas
tions (non-isochrone services)
operable connections
PN IO-Devices
- I/O input area
- I/O output area
per connected PN IO-Device
- I/O input area
- I/O output area
- 10/100 Mbit/s full/half duplex connection with autosensing
- Connection for RJ45
- Multi-protocol operation with TCP and UDP transport
- Adjustable Keep Alive function
- PROFINET IO Controller
- TCP/IP und UDP transport protocol
- Programming device/operator panel communication:
- S7 communication (client, server, multiplexing)
- S5-compatible communication
user program (e.g. HMI)
SIMATIC procedure
systems
protocol
Cross-network by means of S7 routing
SIMATIC S7-300
Siemens ST 70 News · 2006
CP 343-1
Max. 16
16
Max. 48
16
125
2160 byte
2160 byte
Max. 128 byte
Max. 128 byte
Communication
CP 343-1
4/47
4

Related parts for 6ED1 052-1CC01-0BA6