ZEN-10C2AR-AV1 Omron, ZEN-10C2AR-AV1 Datasheet

CPU Unit

ZEN-10C2AR-AV1

Manufacturer Part Number
ZEN-10C2AR-AV1
Description
CPU Unit
Manufacturer
Omron
Datasheet

Specifications of ZEN-10C2AR-AV1

Peak Reflow Compatible (260 C)
No
Signal Input Type
100-240VAC
Output Type
Relay
Supply Voltage
24VDC
Supply Voltage Max
240VAC
No. Of Digital Inputs
6
Mounting Type
DIN Rail/ Bolt-on
Supply Voltage Min
100VAC
No. Of Digital Outputs
4
Rohs Compliant
No
Approval Categories
UL, CE
Leaded Process Compatible
No
For Use With
ZEN Series Logic Controllers
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to “Warranty and Application
Considerations” on page 36, and “Precautions for Safe Use” on page 34.
Even Broader Applications with Increased
Functionality and Higher Precision
• Increased functionality in a compact body (70 mm wide 90 mm
• Easy programming is available using the LCD and operation
• This single Unit easily provides relay, timer, counter, and time
• Expansion is easy with Expansion I/O Units, allowing up to 44
• Economy-type and Communications-type CPU Units have been
• Improved Weekly Timers (See note 1.)
• Select from two power supply options:
Note: 1. Not supported for ZEN-@C2@@-@-V2 models.
Features
Saves Space, Wiring, and Installation Steps
• Versatile functionality in a compact body (70 mm wide
• This single Unit easily provides relay, timer, counter, and time
high).
switch functions. Wiring work is greatly reduced because separate
wiring is not required for devices such as timers and counters.
high).
buttons. (See note 1.)
switch functions.
I/O points. (See note 2.)
added to series.
Increased timing accuracy with a monthly deviation of ±15 s
max. Multiple-day operation and pulse output operation have
been added.
100 to 240 VAC or 12 to 24 VDC.
Programmable Relay
ZEN V2 Units
Easy and Simple Programming for Automatic Small-scale Control
2. When using CPU Units with 20 I/O points.
70 mm
90 mm
90 mm
Easy Programming
The LCD screen comes with 8 operation buttons on the front panel to
enable programming in ladder view format. The LCD screen also has
a backlight, making it easier to see when the ZEN is used in dark
locations.
Note: Not supported for ZEN-@C2@@-@-V2 models.
The information in this document applies to V2 Units.
Refer to page 28 for details on differences with previous
products.
Programmable Relay
ZEN V2 Units
1

Related parts for ZEN-10C2AR-AV1

ZEN-10C2AR-AV1 Summary of contents

Page 1

... Easy Programming 90 mm The LCD screen comes with 8 operation buttons on the front panel to enable programming in ladder view format. The LCD screen also has a backlight, making it easier to see when the ZEN is used in dark locations. Note: Not supported for ZEN-@C2@@-@-V2 models ...

Page 2

... Programs can be simulated on the personal computer without connecting to the ZEN. Note: For notebook computers that do not have an RS-232C serial port, connect the computer to the ZEN by connecting an OMRON CS1W-CIF31 USB-Serial Conversion Cable to the ZEN-CIF01 Connecting Cable. Other Versatile Functions • Use of a Memory Cassette makes it easy to copy and save programs. • ...

Page 3

... I/O points Standard LCD type Economy type ZEN-10C4@ ZEN-20C1@ ZEN-20C3@ Expansion I/O Units cannot be connected. Power Supply Unit Same shape and design as ZEN. 24 VDC Programmable Relay LED type 10 I/O points 20 I/O points ZEN-10C2@ ZEN-20C2@ This CPU Unit has no LCD, operation buttons, or calendar/clock function ...

Page 4

... Unit version classifier E1: Can connect to V2 CPU Units (See note.) Note: Use a ZEN-8E@@/-4E@ to connect to pre-V1 and V1 CPU Units. This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. ...

Page 5

... VAC VDC --- Note: 1. Programming is not possible using only the CPU in the LED-type CPU Unit. ZEN Support Software or a Memory Cassette is required. 2. Cannot be connected to pre-V1 and V1 CPU Units. 3. The ZEN-8E1AR cannot be connected to a CPU Unit with DC power supply. Power Supply Unit ...

Page 6

... CPU Units with DC Power Supplies. 2. The Connecting Cable and Memory Cassette cannot be connected to the ZEN at the same time. 3. Programs cannot be written to LED-type CPU Units (i.e., ZEN-@C2@@-@-V2 models) without the ZEN Support Software or a Memory Cassette. ZEN V2 Units ...

Page 7

... ZEN-8E1AR 100 V AC max. 240 V AC max. Inrush current ZEN-10C@AR-A-V2: 4.5 A max. ZEN-20C@AR-A-V2: 4.5 A max. ZEN-8E1AR: Ambient temperature for ZEN-@C2@@-@-V2 models) Ambient storage temperature for ZEN-@C2@@-@-V2 models) Ambient humidity 10% to 90% (with no condensation) Ambient conditions No corrosive gases Mounting method Surface mounting, DIN track mounting (standard (vertical) installation and horizontal installation) (See notes 1 and 2 ...

Page 8

... Note points for CPU Units with 10 I/O points. With Communications-type CPU Units, however, the CPU Unit has 6 inputs and 3 outputs, for a maximum of 33 I/O points. 2. Not provided for LED-type CPU Unit without display (i.e., ZEN-@C2@@-@-V2 models). Communications Specifications (Communications-type CPU Units) ...

Page 9

... Common Noise AC power supply power supply I/O: 0 CPU Units with AC Power Supplies max. CPU Units with DC Power Supplies max. (level: PS1) Circuit drawing IN 330 k 300 k IN Internal 51 k circuit N L Circuit drawing IN 5 VDC Internal circuit COM ZEN V2 Units 9 ...

Page 10

... OFF voltage 5 VDC max. ON response time (See note 1.) OFF response time Note: 1. Can be selected using the input filter settings. 2. The ZEN-8E1DT has no +/- terminals. There is no need to supply power. ZEN V2 Units 10 Programmable Relay Specifications 5.5 k /14 VDC min. 100 k /14 VDC max. ...

Page 11

... OFF response time 5 ms max. The life under the worst conditions, of the output contacts used in ZEN relay outputs is given in the above table. Guidelines for the normal life of the relays are shown in the diagram on the right. Note: The switching capacity, switching durability, and applicable load area when actually using the relay depend on the type of load, environmental conditions, and switching conditions ...

Page 12

... CPU Unit with 10 I/O points Note: When connecting Expansion I/O Units with DC inputs to a CPU Unit with an AC power supply, the burst noise immunity will (IEC 61000-4-4). ZEN V2 Units 12 Programmable Relay Input device L N IN0 IN1 IN2 IN3 ZEN-8E1AR Expansion I/O Unit (AC input type) ...

Page 13

... Note: When connecting an analog input device, always connect the negative side to the COM terminal. For Connections to Positive (+) Common (NPN Connection VDC Input device + COM CPU Unit with 10 I/O points Note: When connected to the positive (+) common, I4 and I5 cannot be used as analog inputs. ZEN V2 Units Programmable Relay 13 ...

Page 14

... Note: 1. Supply power to both the CPU Unit and Expansion I/O Units from the same power supply and turn them ON and OFF at the same time. 2. ZEN-8E1AR Expansion I/O Units with AC inputs cannot be connected to CPU Units with DC power supply. 3. The input circuit commons for ZEN-8E1DR Expansion I/O Units with relay outputs are each internally connected to one side of the power supply circuit (COM terminal). ...

Page 15

... CPU Unit with 10 I/O Points + + + + Expansion I/O Units Expansion I/O Unit + + OUT2 OUT3 + + OUT0 to OUT3 OUT0 OUT1 CPU Unit with 20 I/O Points Expansion I/O Units Expansion I/O Unit OUT 2 OUT 0 CPU Unit with 20 I/O Points + + + + + Programmable Relay OUT 3 OUT ZEN V2 Units 15 ...

Page 16

... Nomenclature Standard LCD-type, Economy-type, and Communications-type CPU Units (Except for ZEN-@C2@@-@-V2 Models) CPU Units with 10 I/O Points Left side Power supply terminals Display screen Battery Unit connector (Remove the seal to connect the Battery Unit.) CPU Units with 20 I/O Points Left side ...

Page 17

... Setting parameters Button input bit (See page 24.) --- B6 ON --- B7 ON • Moves the cursor and down. • Changes numerals and parameters Moves the cursor right B3 ON and left Cancels the setting B0 ON and returns to the previous operation. Confirms the setting ZEN V2 Units 17 ...

Page 18

... LED-type CPU Units without Display (ZEN-@C2@@-@-V2) CPU Units with 10 I/O Points Left side Front Power supply terminals LED indicators Battery Unit connector (Remove the seal to connect ZEN Support Software connector the Battery Unit.) (also used for Memory Cassette.) CPU Units with 20 I/O Points ...

Page 19

... Work bits can be used only within the ZEN program. I/Os for external devices cannot be made (i.e., all I/O is internal). 16 Used the same as the work bits. However, if the power to the ZEN is turned OFF, these bits also maintain the previous ON/OFF status ON-delay timer ...

Page 20

... Using Holding Timers X: ON-delay timer Trigger input Reset input Setting Present value 0 Timer bit ZEN V2 Units 20 Programmable Relay Turns ON after set delay after the trigger input turns ON. Basic Operation Trigger input Timing Output Main Applications When delayed operation or a time lag is required. ...

Page 21

... Units are connected Refer to the following table for ZEN execution times. The execution times are provided as a guide. External factors, button operations, execution of ZEN Support Software operations, and timing of the processing affects the actual processing times. Common Processing Time ...

Page 22

... Calendar Timer Operation (Only for Standard LCD-type, Economy-type, and Communications-type CPU Units) Dec 31 End date Sep 1 Start date Apr 1 Jan 1 Calendar timer bit The calendar timer bit is ON between 1 April and 31 August. ZEN V2 Units 22 Programmable Relay Ladder program execution time = ( 188 ( s) *5: P0 *4: @0 *3: T0 (output) ...

Page 23

... When are selected, the ZEN switches to the display function screen if the display function is enabled and the specified data is displayed. The Main Screen will no longer be displayed. To display the Main Screen, change the CPU Unit to STOP mode. ...

Page 24

... Password Function (Only for Standard LCD-type, Economy-type, and Communications-type CPU Units) The ZEN has a password function to prevent incorrect manipulation of ladder programs or settings data by other operators. When the password (0000 to 9999) is set, the following operations will not be possible unless the password is input correctly. ...

Page 25

... The operating status can be monitored from the Support Software by connecting to the ZEN using a Connecting Cable (ZEN-CIF01). Note: Both RS-485 communications and the ZEN monitoring function cannot be used at the same time with Communications-type CPU Units. The Support Software can also be used to save files and edit comments. ...

Page 26

... Note: All units are in millimeters unless otherwise indicated. CPU Units CPU Units with 10 I/O Points ZEN-10C@@@-@- 4.7 (Sliding: 13 max.) CPU Units with 20 I/O Points ZEN-20C@@@-@- 4.7 (Sliding: 13 max.) Dimensions with Battery Unit CPU Units with 10 I/O Points 44 45 ZEN V2 Units 26 Programmable Relay 122.5 112 20C1AR-A- ...

Page 27

... Accessories (Order Separately) Battery Unit ZEN-BAT01 DIN Track Hook (Using Slide) 7.6 Two, 3.5 dia 7 Memory Cassette ZEN-ME01 Programmable Relay Mounting Hole Dimensions 54 Two Mounting Hole Dimensions Two Connecting Cable ZEN-CIF01 Cable length: 2m ZEN V2 Units 97 27 ...

Page 28

... M4 spring washer Precautions when Selecting ZEN Programmable Relays Changes in Comparison with Previous Models • The power supply and transistor output voltage ranges for CPU Units and Expansion I/O Units with DC power supply has been expanded to 10.8 to 28.8 VDC. • The width of Expansion I/O Units has been reduced by half and only 8-point models are available. ...

Page 29

... ZEN-8E1@R Expansion I/O Units with relay outputs need to be connected to a power supply. • A ZEN-@C@D@-D-V2 CPU Unit with DC power supply cannot be connected to an Expansion I/O Unit with AC inputs. • When connecting Expansion I/O Units with DC inputs to a CPU Unit with an AC power supply, the burst noise immunity will (IEC 61000- 4-4). • ...

Page 30

... Isolation ZEN-8E1DR: No isolation ZEN-8E1DT: Photocoupler ON voltage 8 VDC min. Input common ZEN-8E1DR: Internally connected to power supply ZEN-8E1DT: Independent common terminal Control output Relay outputs 8 A per output Total for all outputs must be as follows: Units with 10 I/O Points max. Units with 20 I/O Points max. ...

Page 31

... Password change/clear Backlight shut-off time Input filter settings Node number setting Possible Node number setting window displayed. Modem initialization window displayed. --- --- CPU Unit V1 Units Pre-V1 Units 20 I/O points 10 I/O points 12 points 6 points 8 points 4 points 8 points 4 points 8 points 8 points 8 points 8 points ZEN V2 Units 31 ...

Page 32

... CPU Unit type V2 Standard LCD type LED type Communications type Standard LCD type LED type Economy type V1 and Pre-V1 Standard LCD type LED type ZEN V2 Units 32 Programmable Relay Expansion I/O Units Power supply Model AC ZEN-@C1AR-A-V2 ZEN-8E1AR ZEN-@C2AR-A-V2 ZEN-8E1DR ZEN-10C4AR-A-V2 ...

Page 33

... Twin timer operation for timers, multiple-day operation and pulse operation for weekly timers, the 8-digit counter, and 8-digit comparators cannot be used. New Zealand and Australia cannot be set for Daylight Saving Time (DST). Difference between ZEN Programmable Relays and PLC Ladder Program Execution ...

Page 34

... Use special packing boxes when transporting the ZEN and do not subject it to excessive shock or vibration or drop it during shipment. • Store the ZEN within the rated ranges. If the ZEN has been stored lower, allow it to stand at room temperature for three hours or longer before turning ON the power supply. ...

Page 35

... Handling • Connect connectors only after confirming that the direction or polarity is correct. • Failures could result if dust or dirt enters the ZEN. Always connect the connector cover to the computer connector whenever it is not being used. • Do not remove the label from the left side of the CPU Unit if a Battery Unit is not mounted ...

Page 36

... Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron ...

Page 37

Cat. No. L106-E1-06rev 11/06 Specifications subject to change without notice Printed in USA ...