Specifications of E5GN-C1LD-C AC/DC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Svhc
No SVHC (15-Dec-2010)
Accuracy
±0.3 Of PV
Approval Bodies
CE, CSA
Approval Category
UL Recognised
Colour
Black
External
RoHS Compliant
New 48 x 24-mm Basic Temperature
Controller with Enhanced Functions and
Performance. Improved Indication
Accuracy and Preventive Maintenance
Function.
Main I/O Functions
• Indication Accuracy
• Models are available with screw terminal blocks or screwless
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
• Switch the PV display between three colors.
• Compatible with Support Software (CX-Thermo version 4.2 or higher).
• Eleven-segment displays.
• Models are available with one or two alarm outputs.
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
Basic-type Digital Temperature Controller
E5GN
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
clamp terminal blocks.
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.
using a Control Output ON/OFF Counter.
(Models with temperature inputs)
(Models with analog inputs)
This datasheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
Event Inputs
• None
• Two
(48 x 24 mm)
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
E5GN
Dual Display: PV and SV
Auxiliary Outputs
• None
• One
• Two
Models with Screw Terminal
48 × 24 mm
Blocks
Refer to Safety Precautions for E5
E5GN
4-digit Display
• Auto/manual switching
• Temperature Controller status display
• Simple program function
• Control output ON/OFF count alarm
• PV change rate alarm
• Models also available with RS-232C
• Models also available with RS-485
communications
communications
Models with Screwless Clamp
Terminal Blocks
CSM_E5GN_DS_E_3_1
48 × 24 mm
E5GN--@-C
@
N/E5
@
N-H.
1

Related parts for E5GN-C1LD-C AC/DC24

E5GN-C1LD-C AC/DC24 Summary of contents

Page 1

... This datasheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) Models with Screw Terminal E5GN ...

Page 2

... Power Supply Voltage Blank: 100 to 240 VAC D: 24 VAC/VDC 6. Terminal Type Blank: Models with screw terminal block C: Models with screwless clamp terminal block 7. Case Color Blank: Black 8. Communications Protocol Blank: None FLK: CompoWay/F communications E5GN auxiliary outputs auxiliary outputs auxiliary outputs auxiliary outputs 2 ...

Page 3

... E5GN-RT E5GN-R1TC E5GN-R1P E5GN-R1T --- --- E5GN-R1BT E5GN- --- --- R101T-FLK E5GN E5GN E5GN- -R03TC-FLK -R03P-FLK R103T-FLK --- --- E5GN-R2T --- --- E5GN-R2HT --- --- E5GN-R2BT E5GN- --- --- R203T-FLK E5GN-QTC E5GN-QP E5GN-QT E5GN-Q1TC E5GN-Q1P E5GN-Q1T --- --- E5GN-Q1BT E5GN- --- --- Q101T-FLK E5GN E5GN E5GN- -Q03TC-FLK -Q03P-FLK Q103T-FLK --- --- E5GN-Q2T --- --- E5GN-Q2HT --- --- E5GN-Q2BT E5GN- --- --- Q203T-FLK --- --- E5GN-C1T --- --- ...

Page 4

... E5GN-R1TC E5GN-R1P E5GN-R1TD --- --- E5GN-R1BTD E5GN --- --- -R101TD-FLK E5GN E5GN E5GN -R03TC-FLK -R03P-FLK -R103TD-FLK --- --- E5GN-R2TD --- --- E5GN-R2HTD --- --- E5GN-R2BTD E5GN --- --- -R203TD-FLK E5GN-QTC E5GN-QP E5GN-QTD E5GN-Q1TC E5GN-Q1P E5GN-Q1TD E5GN- --- --- Q1BTD E5GN- --- --- Q101TD-FLK E5GN E5GN E5GN -Q03TC-FLK -Q03P-FLK -Q103TD-FLK --- --- E5GN-Q2TD E5GN- --- --- Q2HTD E5GN- --- --- Q2BTD E5GN --- --- -Q203TD-FLK --- ...

Page 5

... RS-485 --- --- Transfer output using --- control output E5GN Previous model Resistance New model Thermocou- thermome- ple input ter input E5GN- --- --- R103L-FLK E5GN- --- --- Q103L-FLK --- --- E5GN-C1L Previous model Resistance New model Thermocou- thermome- ple input ter input E5GN- --- --- R103LD-FLK E5GN --- --- -Q103LD-FLK --- --- E5GN-C1LD 5 ...

Page 6

... E5GN-RT-C E5GN-R1TC E5GN-R1P E5GN-R1T-C --- --- E5GN-R1BT-C E5GN --- --- -R101T-C-FLK E5GN E5GN E5GN -R03TC-FLK -R03P-FLK -R103T-C-FLK --- --- E5GN-R2T-C --- --- E5GN-R2HT-C --- --- E5GN-R2BT-C E5GN --- --- -R203T-C-FLK E5GN-QTC E5GN-QP E5GN-QT-C E5GN-Q1TC E5GN-Q1P E5GN-Q1T-C --- --- E5GN-Q1BT-C E5GN --- --- -Q101T-C-FLK E5GN E5GN E5GN -Q03TC-FLK -Q03P-FLK -Q103T-C-FLK --- --- E5GN-Q2T-C --- --- E5GN-Q2HT-C --- --- E5GN-Q2BT-C E5GN --- --- -Q203T-C-FLK --- --- E5GN-C1T-C --- --- ...

Page 7

... E5GN-RTD-C E5GN-R1TC E5GN-R1P E5GN-R1TD-C --- --- E5GN-R1BTD-C E5GN --- --- -R101TD-C-FLK E5GN E5GN E5GN -R03TC-FLK -R03P-FLK -R103TD-C-FLK --- --- E5GN-R2TD-C --- --- E5GN-R2HTD-C --- --- E5GN-R2BTD-C E5GN --- --- -R203TD-C-FLK E5GN-QTC E5GN-QP E5GN-QTD-C E5GN-Q1TC E5GN-Q1P E5GN-Q1TD-C --- --- E5GN-Q1BTD-C E5GN --- --- -Q101TD-C-FLK E5GN E5GN E5GN -Q03TC-FLK -Q03P-FLK -Q103TD-C-FLK --- --- E5GN-Q2TD-C --- --- E5GN-Q2HTD-C --- --- E5GN-Q2BTD-C E5GN --- --- -Q203TD-C-FLK --- --- E5GN-C1TD-C --- --- ...

Page 8

... Note: The Waterproof Packing is included with the Controller only for models with screw terminal blocks. Current Transformers (CTs) Hole diameter 5.8 dia. 12.0 dia. CX-Thermo Support Software Model EST2-2C-MV4 Note: The E5GN is supported by CX-Thermo version 4.2 and higher. Detection of heater burnout, No. of event Transfer SSR failure, inputs ...

Page 9

... ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment Ambient operating temperature −10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C Ambient operating humidity 25% to 85% −25 to 65°C (with no condensation or icing) Storage temperature E5GN 9 ...

Page 10

... U N 1700 1700 1300 850 850 600 400.0 400 400.0 400 400.0 −100 −200 −199.9 −200 −200 −199.9 −200 Voltage E5GN Infrared temperature sensor 115 140 120 II 70°C 165 260 °C °C °C 2300 1800 1300 260 120 165 90 100 0 ...

Page 11

... Controllers User's Manual Basic Type (Cat. No. H156) for H < > 0 H ≥ L information on the loop burnout alarm (LBA). *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature H > < 0 Controllers User's Manual Basic Type (Cat. No. H156) for H ≤ L ...

Page 12

... Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.2 or higher Provided on the side of the E5GN. Connect this port to the computer when using the Setup Tool. An E58-CIFQ1 USB-Serial Setup Tool port Conversion Cable is required to connect the computer to the port on the side of the E5GN. *6 Approved UL 61010-1, CSA C22 ...

Page 13

... ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 200 100 E5GN 250 VAC, 30 VDC 50 (resistive load) cosφ 0.1 0.2 0.3 0 Switching current (A) E5GN 13 ...

Page 14

... E5GN-@-C Models with Screwless Clamp Terminal Blocks m • 5.8 mm max. 5.8 mm max. E5GN A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input error is sent to the output to which the alarm 1 function is assigned. Analog input Models with Screwless Clamp Terminal Blocks ...

Page 15

... Nomenclature E5GN The front panel is the same for the E5GN. Temperature unit Operation indicators Level Key Dimensions E5GN 48 Models with Screw Terminal Blocks 35 24 Mounted Separately +0 min. E5GN-@-C 48 Models with Screwless Clamp Terminal Blocks 35 24 Mounted Separately +0 min. Accessories (Order Separately) ...

Page 16

... Two, 3.5 dia. 2.36 dia dia. 9 Two, M3 (depth: 4) Armature Lead E5GN E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 100 ∞ 10 Distortion 1 kΩ ...

Page 17

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords