XCMD2110L1 SQUARE D, XCMD2110L1 Datasheet - Page 137

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2110L1

Manufacturer Part Number
XCMD2110L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2110L1

Actuator Style
Top Plunger
Operating Force Max
0.06N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Osiswitch
XCR and XCRT
03/2007
Environmental characteristics
Conforming to standards
Product certifications
Protective treatment
Ambient air temperature
Vibration resistance
Shock resistance
Electric shock protection
Degree of protection
Enclosure
Cable entry
Contact block characteristics
Rated operational characteristics
Rated insulation voltage
Rated impulse withstand voltage
Positive operation (depending on model)
Resistance across terminals
Short-circuit protection
Cabling
Minimum actuation speed
Electrical durability
®
Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift Monitoring
Products
Machine assemblies
Standard version
Special version
Standard version
Screw clamp terminals
a.c. supply
a 50/60 Hz
d.c. supply c
inductive circuit
IEC/EN 60947-5-1, VDE 0660-200 (CSA C22-2 n° 14 for XCR), CCC (for XCR)
IEC/EN 60204-1, NF C 79-130
XCRA, B, E, F: CSA A300
XCRA, B, E, F: CSA A300, 1/2" NPT
“TC”
Operation: -25…+70 °C (-13…+158 °F); Storage: -40…+70 °C (-40…+158 °F)
9 gn (10…500 Hz)
XCRA, B, E, F: 68 gn; XCRT: 30 gn (18 ms)
Class I conforming to IEC 60536 and NF C 20-030
XCRA, B, E, F: IP 54 conforming to IEC 60529; IP 545 conforming to NF C 20-010
XCRT: IP 65 conforming to IEC 60529; IP 655 conforming to NF C 20-010
Metal, except XCRT315: polyester
Tapped entry for PG 13 (PG 13.5) conduit thread
a AC-15; A300 (Ue = 240 V, Ie = 3 A)
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Ui = 500 V degree of pollution 3 conforming to IEC 60947-1 and VDE 0110, group C conforming to NF C 20-040
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
U imp = 6 kV conforming to IEC 60947-1, IEC 60664
N/C contacts with positive opening operation to IEC 60947-5-1 Section 3, EN 60947-5-1
10 A cartridge fuse type gG (gl)
XE2SP2151: Clamping capacity, min: 1 x 0.34 mm
XE2NP2151: Clamping capacity, min: 1 x 0.5 mm
XCRT contacts: Clamping capacity, min: 1 x 0.5 mm
XE2SP2151 and XCRT contacts: 0.01 m/minute (0.03 ft/minute),
XE2NP2151: 6 m/minute (19.68 ft/minute)
Conforming to IEC 60947-5-1 Appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles per hour
Load factor: 0.5
XE2SP2151
XCRT contacts
Power switched in W for 5 million
operating cycles W
For XE2SP2151 on a or c N/C and N/O contacts simultaneously loaded to the values shown with reverse
polarity.
25 m conforming to NF C 93-050 method A or IEC 60255-7 category 3
0,5
0,1
0,5
0,1
5
4
3
2
5
1
1
0,5
0,5
230/400 V
110 V
230 V
1
1
2
2
48 V
3 4
3 4
12/24 V
24 V
48 V
Current in A
110 V
Current in A
Voltage
XE2SP2151
XE2NP2151
XCRT contacts
5
© 1997–2007 Schneider Electric All Rights Reserved
5
Ithe
Ithe
10
10
2
, max: 2 x 2.5 mm
2
, max: 2 x 1.5 mm
2
, max: 2 x 2.5 mm
24 V
10
13
10
XE2NP2151
0,5
0,2
0,1
5
4
3
2
2
1
2
0,5
2
48 V
7
9
7
1
230 V
2
110 V
3 4 5
120 V
4
7
4
12/24/48 V
Current in A
Ithe
10
137

Related parts for XCMD2110L1