XCMD2110L1 SQUARE D, XCMD2110L1 Datasheet - Page 99

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2110L1

Manufacturer Part Number
XCMD2110L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2110L1

Actuator Style
Top Plunger
Operating Force Max
0.06N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Osiswitch
XCKJ
03/2007
Contact block characteristics
Rated operational
characteristics
Rated insulation voltage
Rated impulse withstand
voltage
Positive operation (depending on model)
Resistance across terminals
Short-circuit protection
Cabling
(screw clamp terminals)
Minimum actuation speed
Electrical durability
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
®
Classic, Metal, Conforming to CENELEC EN 50041
XE2SP21•1, XE2SP2141
Power switched in W for 5 million
operating cycles.
Voltage
o
For XE2SP•151 on
XE3NP••••
Power switched in W for 5 million
operating cycles.
Voltage
o
0,5
0,1
0,5
0,1
5
1
5
1
0,5
0,5
230/400 V
230/400 V
110 V
110 V
V
W
V
W
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2SP21•1
XE2NP21•1
XCKJ plug-in and XESP20•1
XE3NP and XE3SP
1
1
24
10
24
3
2
a
2
or
3 4
3 4
c
24 V
48 V
24 V
48 V
48
7
48
2
, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity.
Current in A
Current in A
5
5
Ithe
Ithe
10
10
120
4
120
1
a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1
a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1
Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
U imp = 6 kV conforming to IEC 60947-1, IEC 60664
U imp = 4 kV conforming to IEC 60947-1, IEC 60664
N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1
y 25 m conforming to IEC 60255-7 category 3
10 A cartridge fuse type gG (gl)
6 A cartridge fuse type gG (gl)
Clamping capacity, min: 1 x 0.34 mm
Clamping capacity, min: 1 x 0.5 mm
Clamping capacity, min: 1 x 0.75 mm
Clamping capacity, min: 1 x 0.34 mm
XE2SP21•1 and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1 and XE3NP: 6 m/minute (19.68 ft/minute)
XE2NP21•1
Power switched in W for 5 million
operating cycles.
Voltage
o
XE3SP••••
Power switched in W for 5 million
operating cycles.
Voltage
o
0,5
0,2
0,5
0,2
0,1
0,1
5
4
3
2
Conforming to IEC 60947-5-1 Appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles/hour
Load factor: 0.5
5
4
3
2
1
1
0,5
0,5
V
W
V
W
1
1
230 V
230 V
24
13
24
4
2
2
110 V
48
9
110 V
48
3
3 4 5
3 4 5
12/24/48 V
12/24/48 V
Current in A
Current in A
2
120
7
120
2
Ithe
© 1997–2007 Schneider Electric All Rights Reserved
, max: 2 x 2.5 mm
2
2
2
, max: 2 x 1.5 mm
, max: 2 x 1.5 mm
, max: 1 x 1 mm
Ithe
10
10
2
2
or 2 x 0.75 mm
2
2
XCKJ plug-in, XESP20•1
Power switched in W for 5 million
operating cycles.
Voltage
o
0,5
0,1
5
4
3
2
1
0,5
2
230 V
V
W
1
24
10
2
48 V
48
7
3 4
12/24 V
110 V
Current in A
5
120
4
Ithe
10
99

Related parts for XCMD2110L1