XCMD2110M12 SQUARE D, XCMD2110M12 Datasheet - Page 127

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 3A

XCMD2110M12

Manufacturer Part Number
XCMD2110M12
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 3A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2110M12

Actuator Style
Top Plunger
Operating Force Max
0.06N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
3A
Contact Current Dc Max
3A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Osiswitch
XCKS—Double Insulated
03/2007
Contact block characteristics
Rated operational
characteristics
Rated insulation voltage
Rated impulse withstand
voltage
Positive operation (depending on model)
Resistance across terminals
Short-circuit protection
Cabling
(screw and captive cable
clamp terminals)
Minimum actuation speed
Electrical durability
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
a.c. supply
a 50/60 Hz
o inductive
circuit
d.c. supply c
®
Classic, Plastic, Conforming to CENELEC EN 50041
XE2SP21•1, XE2SP2141
Power switched in W for 5 million operating
cycles.
Voltage
o
For XE2SP•151 on
XE3SP••••
Power switched in W for 5 million
operating cycles.
Voltage
o
0,5
0,1
0,5
0,1
5
1
0,5
5
1
0,5
230/400 V
230/400 V
110 V
110 V
V
W
V
W
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2SP21•1
XE2NP21•1
XESP3021
XE3NP and XE3SP
1
1
24
10
24
3
2
a
2
or
3 4
48
7
3 4
48
2
c
Current in A
24 V
48 V
, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity.
48 V
24 V
Current in A
5
5
Ithe
120
4
120
1
Ithe
10
10
a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0,27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
a AC-15; B300 (Ue = 240 V, Ie = 1,5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0,1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
U imp = 6 kV conforming to IEC 60947-1, IEC 60664
U imp = 4 kV conforming to IEC 60947-1, IEC 60664
N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K,
EN 60947-5-1
y 25 m conforming to IEC 60255-7 category 3
10 A cartridge fuse type gG (gl)
6 A cartridge fuse type gG (gl)
Clamping capacity, min.: 1 x 0.34 mm
Clamping capacity, min.: 1 x 0.5 mm
Clamping capacity, min.: 1 x 0.75 mm
Clamping capacity, min.: 1 x 0.34 mm
XE2SP21•1, XESP3021 and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1 and XE3NP: 6 m/minute (19.68 ft/minute)
XE2NP21•1
Power switched in W for 5 million operating cycles.
Voltage
o
XE3NP••••
Power switched in W for 5 million operating
cycles.
Voltage
o
0,2
0,5
0,1
0,5
0,2
0,1
Conforming to IEC 60947-5-1 Appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles per hour
Load factor: 0.5
5
4
3
2
1
5
4
3
2
1
0,5
0,5
V
W
V
W
1
1
230 V
230 V
13
4
24
24
2
2
110 V
110 V
3 4 5
12/24/48 V
3 4 5
12/24/48 V
48
9
48
3
Current in A
Current in A
2
Ithe
© 1997–2007 Schneider Electric All Rights Reserved
, max.: 2 x 2.5 mm
2
2
2
, max.: 2 x 1.5 mm
, max.: 2 x 1.5 mm
, max.: 1 x 1 mm
120
7
120
2
Ithe
10
10
2
2
or 2 x 0.75 mm
2
2
XESP3021
Power switched in W for 5 million operating cycles.
o
Voltage
0,5
0,1
5
4
3
2
1
0,5
230 V
2
V
W
1
24
10
2
48 V
3 4
12/24 V
48
7
110 V
Current in A
5
120
4
Ithe
10
127