XCMD2110M12 SQUARE D, XCMD2110M12 Datasheet - Page 54

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 3A

XCMD2110M12

Manufacturer Part Number
XCMD2110M12
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 3A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2110M12

Actuator Style
Top Plunger
Operating Force Max
0.06N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
3A
Contact Current Dc Max
3A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Osiswitch
Universal, XCKP and XCKT Plastic / XCKD Metal
54
b XCKP, XCKD
with 1 cable entry
Conforming to CENELEC EN 50047
b XCKT
with 2 cable entries
Tripping/resetting points and mounting centers conform
to CENELEC EN 50047
Environmental characteristics
Conforming to standards
Product certifications
Protective treatment
Ambient air temperature
Vibration resistance
Shock resistance
Electric shock protection
Degree of protection
Repeat accuracy
Cable entry or
integral connector
Materials
© 1997–2007 Schneider Electric All Rights Reserved
®
Compact
Products
Machine assemblies
Standard version
Operation
Storage
Conforming to IEC 60068-2-6
Conforming to IEC 60068-2-27
Depending on model
v With head for linear movement (plunger). Mounting by the head or by the body.
XCKD
Pages 56 and 60
v With head for rotary movement (lever) or multi-directional. Mounting by the body.
XCKD
Pages 57 and 61
v With head for linear movement (plunger). Mounting by the head or by the body.
XCKT
Page 68
v With head for rotary movement (lever) or multi-directional. Mounting by the body.
XCKT
Page 68
IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
IEC 60204-1, EN 60204-1
UL, CSA, CCC
“TC”
- 25…+70 °C (-13…+158 °F)
- 40…+70 °C (-40…+158 °F)
25 gn (10…500 Hz) except switch with head ZCE 24: 20 gn
50 gn (11 ms) except heads ZCE08: 15 gn (11 ms) and ZCE24: 30 gn (18 ms)
Class II conforming to IEC 61140 and NF C 20-030 for XCKP and XCKT
Class I conforming to IEC 61140 and NF C 20-030 for XCKD
IP 66 and IP 67 conforming to IEC 60529; IK 04 conforming to EN 50102 for XCKP and XCKT, IK 06
conforming to EN 50102 for XCKD
0.1 mm on the tripping points, with 1 million operating cycles for head with end plunger
Either: tapped entry for PG 11 or PG 13 conduit thread, tapped ISO M16 x 1.5 or ISO M20 x 1.5,
tapped 1/2" NPT, tapped PF 1/2 (G1/2) or integral M12 connector
XCKD: Zamak
®
bodies and heads, XCKP and XCKT: plastic bodies, Zamak heads
XCKP
Pages 62 and 66
XCKP
Pages 63 and 67
03/2007

Related parts for XCMD2110M12