XCMD2115L1 SQUARE D, XCMD2115L1 Datasheet - Page 18

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2115L1

Manufacturer Part Number
XCMD2115L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2115L1

Actuator Style
Roller Lever
Operating Force Max
0.1N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Selection Guide
Osiswitch
18
Contact blocks (continued)
max.
21 - 22
13 - 14
0
1
2
P
21 - 22
13 - 14
21 - 22
13 - 14
0
1
2
P
max.
0
© 1997–2007 Schneider Electric All Rights Reserved
0
B
C
C
B
B
C
1
1
D
®
B
C
XC Product Overview
D
A
A
P
P
P
P
2
2
A
A
Tripping
and
Resetting
Resetting
Tripping
Functional diagrams of snap action contacts
Example: N/C + N/O
A—Maximum travel of the operator in mm or degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in mm.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Rotary movement (lever)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Functional diagrams of slow break contacts
Example: N/C + N/O break before make
A—Maximum travel of the operator in mm or degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in mm.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
Rotary movement (lever)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
03/2007