XCMD2115L1 SQUARE D, XCMD2115L1 Datasheet - Page 83

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2115L1

Manufacturer Part Number
XCMD2115L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2115L1

Actuator Style
Roller Lever
Operating Force Max
0.1N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Osiswitch
XCKM, XCKL, and XCKML
03/2007
Contact block characteristics
Rated operational
characteristics
Rated insulation voltage
Rated impulse
withstand voltage
Positive operation (depending on model)
Resistance across terminals
Short-circuit protection
Cabling
(screw and captive cable
clamp terminals)
Minimum actuation speed
Electrical durability
®
Classic, Metal
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2•P
XE3•P
XE2SP21•1
XE2NP21•1
XESP2151L and XENP2151L
XE3NP et XE3SP
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0,27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
a AC-15; B300 (Ue = 240 V, Ie = 1,5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0,1 A), conforming to IEC 60947-5-1 Appendix A,
EN 60947-5-1
Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
U imp = 6 kV conforming to IEC 60947-1, IEC 60664
U imp = 4 kV conforming to IEC 60947-1, IEC 60664
N/C contacts with positive opening operation conforming to IEC 947-5-1 Section 3, EN 60 947-5-1
y 25 m conforming to IEC 60255-7 category 3
10 A cartridge fuse type gG (gl)
6 A cartridge fuse type gG (gl)
Clamping capacity, min: 1 x 0,34 mm
Clamping capacity, min: 1 x 0,5 mm
Clamping capacity, min: 1 x 0,34 mm
Clamping capacity, min: 1 x 0,34 mm
XE2SP21•1, XESP2151L and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1, XENP2151L and XE3NP: 6 m/minute (19.68 ft/minute)
XE2SP21•1, XE2SP2141, XESP2151L
Power switched in W for 5 million operating
cycles
Voltage
o
For XE2SP•151 on a or c, the “N/C” and “N/O” contacts are simultaneously loaded to the values shown with reverse
polarity.
XE3SP••••
Power switched in W for 5 million operating
cycles
Voltage
o
0,5
0,1
0,5
0,1
Conforming to IEC 60947-5-1 appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles/hour
Load factor: 0,5
5
1
5
1
0,5
0,5
230/400 V
230/400 V
110 V
110 V
1
1
V
W
V
W
24
10
24
3
2
2
3 4
3 4
48
7
48
2
24 V
48 V
24 V
48 V
Current in A
Current in A
5
5
2
Ithe
, max: 2 x 2,5 mm
2
2
2
, max: 2 x 1,5 mm
, max: 2 x 1,5 mm
, max: 1 x 1 mm
120
4
120
1
Ithe
10
10
© 1997–2007 Schneider Electric All Rights Reserved
2
2
or 2 x 0,75 mm
2
2
or 1 x 2,5 mm
XE2NP21•1, XENP2151L
Power switched in W for 5 million operating
cycles
Voltage
o
XE3NP••••
Power switched in W for 5 million operating
cycles
Voltage
o
0,5
0,2
0,5
0,2
0,1
0,1
2
2
5
4
3
1
5
4
3
1
0,5
0,5
2
2
1
1
V
W
V
W
230 V
230 V
24
13
24
4
2
2
110 V
110 V
3 4 5
3 4 5
12/24/48 V
12/24/48 V
48
9
48
3
Current 1n A
Current in A
Ithe
120
7
120
2
Ithe
10
10
83