XCMD2116L1 SQUARE D, XCMD2116L1 Datasheet - Page 152

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2116L1

Manufacturer Part Number
XCMD2116L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2116L1

Actuator Style
Roller Lever
Operating Force Max
0.1N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
Snap Action Industrial Switches
Class 9007
Acceptable Wire Size . . . . . . . . . . . . .14–22 AWG
Recommended Terminal Clamp Torque 6–9 lb-in (0.7–1 Nkm)
152
Industrial Snap Switches and Limit Switches without Enclosures
Industrial Snap Switches have been incorporated in many Square D
specialty push buttons, foot switches, operating mechanisms, door interlocks, motor control centers,
position switches, and many other control products.
Quick Make and Break
Type of
Operator
Basic
Snap Switch
Rigid Roller
Lever Type
k
Maximum Current Ratings For Control Contacts—All Types
Switch
Type
AO1, AC
AW, AO2
and AO6,
AB, AP
AW, CO3
and CO6,
CB, CC,
CP
Single-pole snap switches that contain two double-break contact elements (1 N.O. and 1 N.C.) must
be used on circuits of the same polarity. Two-pole snap switches contain two electrically separated
sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double-
break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.
Recommended Actuator—An adjustable actuator is recommended. If a non-adjustable actuator is used,
a resilient type or a mechanical stop should be used to prevent bottoming of button mechanism.
Adjustable Actuator Overtravel—Minimum recommended overtravel in both trip and reset directions is 0.015 in. (0.38 mm).
Non-Adjustable Actuator Total Travel—Maximum differential limit plus 0.030 in. (0.76 mm). Example: 0.076 in. (1.9 mm) for Type AO2.
Non-Adjustable Actuator Total Travel—Fully retracted—from mounting surface, at least 0.139 in. (3.5 mm) for Type AO1 and 0.160 in.
(4.0 mm) for Types AO2 and CO3. Fully engaged—from mounting surface, at least 0.061 in. (1.5 mm) but not closer than 0.045 in. (1.1 mm).
© 1997–2007 Schneider Electric All Rights Reserved
Contacts
SPDT
Form Z
SPST k
Form X or Y
SPDT
Form Z
SPST k
Form X or Y
DPDT
Form ZZ
DPST
Form AA or BB
Contact
Arrangement
1 N.O.
1 N.C.
1 N.C.
1 N.O.
1 N.O.
1 N.C.
1 N.C.
1 N.O.
2 N.O.
2 N.C.
2 N.O.
Two Stage
2 N.O.
2 N.C.
1 N.O.
1 N.C.
Direct
Opening
Contacts Meet
IEC 60947-5-1
Requirements
No
No
No
k
Type
AO 1
AO 1A
AO 1B
AO 2
AO 6 (Plug-in)
AO 2A
AO 2B
CO 3
CO 6 (Plug-in)
CO 7
AB 21 (RH) q
AB 22 (LH) q
AB 41 q
(without Side
Mtg. Bracket)
AB 23 (RH) f
AB 24 (LH) f
Voltage
120
240
480
600
120
240
480
600
120
240
480
600
Type of
Operator
Rigid Roller
Lever Type
Rigid Roller
Lever Type
One Way Roller
Cabinet
Door Type
Plunger Type
Panel Mounting
A
40
20
10
40
20
10
30
15
8
8
7.5
6
Make
35% Power Factor
VA
Contact
Arrangement
2 N.O.
2 N.C.
1 N.O.
1 N.C.
2 N.O.
2 N.C.
1 N.O.
1 N.C.
2 N.O.
2 N.C.
1 N.O.
1 N.C.
2 N.O.
2 N.C.
Operator Only
4800
4800
4800
4800
4800
4800
4800
4800
3600
3600
3600
3600
AC—50 or 60 Hz
Inductive
A
15
10
6
5
15
10
6
5
3
1.5
0.75
0.6
®
File E42259
CCN NKCR2
products such as timers,
Break
k
VA
1800
2400
2880
3000
1800
2400
2880
3000
360
360
360
360
CB 36 (LH)
Type
CB 31 (RH) q
CB 32 (LH) q
CB 41 q
(without Side Mtg. Bracket)
CB 33 (RH) f
CB 34 (LH) f
AB 25 (RH)
AB 26 (LH)
CB 35 (RH)
AC 1
CC 1
AP 221
CP 221
AP 201 t
j
q
f
t
Roller turned 90° from standard (perpendicular to mounting holes).
With 0.22 in. (5.6 mm) width roller.
With 0.47 in. (12.0 mm) width roller.
For use with Type AO and CO basic switches.
Resistive 75%
Power Factor
Make and
Break
Amperes
15
10
6
5
15
10
6
5
3
1.5
0.75
0.6
®
File LR25490
Class 3211-03
Voltage
125
250
600
125
250
600
125
250
600
Type of
Operator
Roller
Plunger Type
Panel Mounting
Non-Oiltight
Roller
Plunger Type
Panel Mounting
Oiltight
Mushroom
Button Type
Panel Mounting
Inductive and Resistive
Single
Pole
0.5
0.25
0.05
2.0
0.5
0.1
1.0
0.3
0.1
Make and Break
DC
Type AB21
Amperes
Contact
Arrangement
1 N.O.
1 N.C.
2 N.O.
2 N.C.
Operator Only
1 N.O.
1 N.C.
2 N.O.
2 N.C.
Operator Only
1 N.O.
1 N.C.
2 N.O.
2 N.C.
Operator Only
Double
Pole
0.25
0.1
0.5
0.2
0.02
0.2
0.1
Marking
Type AO2
AC or DC
Continuous
Carrying
Amperes
15
15
15
15
15
15
15
15
10
10
10
10
Type
AP 321
AP 324 j
CP 321
CP 324 j
AP 301 t
AP 304 j t
AP 323
AP 325 j
CP 323
CP 325 j
AP 303 t
AP 305 j t
AP 222
CP 222
AP 202 t
03/2007