XCMD2116L1 SQUARE D, XCMD2116L1 Datasheet - Page 180

LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A

XCMD2116L1

Manufacturer Part Number
XCMD2116L1
Description
LIMIT SWITCH, 1NO.1NC, 240VAC, 250VDC, 6A
Manufacturer
SQUARE D
Datasheet

Specifications of XCMD2116L1

Actuator Style
Roller Lever
Operating Force Max
0.1N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Contact Current Dc Max
6A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
180
© 1997–2007 Schneider Electric All Rights Reserved
Special features and modifications
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Optional shafts
Description
Optional shaft, 7.8 mm (0.306 in.) diameter:
To accommodate lever arms from the obsolete Denison C limit switches. Available on all
9007C, CF, or CR limit switches
Optional shaft, 7.1 mm (0.28 in.) diameter:
Available on all 9007C, CF, or CR limit switches
Switch with adapter plate
Description
Switch with adapter plate permitting substitution of any 9007C switch with standard
body for any type T switch with style B base plate
Direct acting contacts / Positive opening contacts
One pole, normally closed, slow make-slow break, direct acting contact mechanism substituted for standard snap switch on
9007C52, C54 and CR53 devices.
This mechanism was designed for use in emergency overtravel applications. The movable contact of this basic switch unit is
acted upon directly by the actuating mechanism of the limit switch and is not dependent upon the force exerted by a snap switch
blade or spring to open the circuit. Because these contacts are slow make-slow break, they are best suited for applications
where they are not actuated during normal operation, but only if abnormal overtravel is encountered.
Electrical contact ratings
Volts
120
240
480
600
1.
Description
Direct acting contact/positive opening contact block (slow break single pole only)
9007C52 compact unit ratings at 125 Vdc—same ratings as 9007C54 and 9007CR53 at other voltages.
A
60
30
15
12
maximum current—35 % power factor
Make
VA
7200
7200
7200
7200
AC—NEMA A600
A
6
3
1.5
1.2
Break
VA
720
720
720
720
(continued)
Continuous
carrying
A
10
10
10
10
Y1561
Volts
125
250
600
A
1.1/0.55 (1)
0.27
0.10
DC maximum current
Make or break
Suffix to add to the
device catalog
number
Y1561
Suffix to add to the
device catalog
number
Y247
Y249
Suffix to add to the
device catalog
number
Y147
VA
138/69 (1)
67.5
60
Continuous
carrying
A
5/2.5 (1)
2.5
2.5
0.566 (1.25)
0.57 (1.25)
0.57 (1.25)
03/2007
Weight
Weight
Weight
kg (lb)
kg (lb)
kg (lb)

Related parts for XCMD2116L1