AC Motor Drive

3G3JX-AE022

Manufacturer Part Number3G3JX-AE022
DescriptionAC Motor Drive
ManufacturerOmron
3G3JX-AE022 datasheet
 

Specifications of 3G3JX-AE022

Supply Voltage Range200V To 240VNo. Of PhasesSingle Or Three
Power Rating2200WOutput Voltage Max240V
Output Frequency Max400HzMounting TypeDIN Rail
Output Voltage Min200VExternal Height189mm
Frequency Range0.5 To 400HzRohs CompliantYes
External Depth157.5mmExternal Width110mm
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
Page 41
42
Page 42
43
Page 43
44
Page 44
45
Page 45
46
Page 46
47
Page 47
48
Page 48
49
Page 49
50
Page 50
51
52
53
54
55
56
57
Page 44/57

Download datasheet (6Mb)Embed
PrevNext
Display on Digital
Name
Operator
ek6k0.
Option 1 error
ek6k9.
ek7k0.
Option 2 error
ek7k9.
*1. The reset command will not be accepted until approximately 10 seconds pass since the trip occurs (protection function works)
*2. The reset command will not be accepted if the EEPROM error
possible that the memory element has been broken or the parameters have not been memorized correctly. Perform the user initialization to set the parameters
again.
*3. The reset command through the RS terminal or STOP/RESET key will not be accepted. Turn off the power.
*4. The reset operation via the Digital Operator will not be accepted. Be sure to reset via the RS terminal.
52
Advanced General-purpose Inverters SYSDRIVE
Detects an error on the board mounted on option slot 1. For details, refer to the operation manual for the
mounted option board.
Detects an error on the board mounted on option slot 2. For details, refer to the operation manual for the
mounted option board.
occurs. Turn off the power once. If you find E08 when turning on the power again, it is
ek0k8.
RX
Series
Description