3G3JX-AE022 Omron, 3G3JX-AE022 Datasheet - Page 9

AC Motor Drive

3G3JX-AE022

Manufacturer Part Number
3G3JX-AE022
Description
AC Motor Drive
Manufacturer
Omron
Datasheet

Specifications of 3G3JX-AE022

Supply Voltage Range
200V To 240V
No. Of Phases
Single Or Three
Power Rating
2200W
Output Voltage Max
240V
Output Frequency Max
400Hz
Mounting Type
DIN Rail
Output Voltage Min
200V
External Height
189mm
Frequency Range
0.5 To 400Hz
Rohs Compliant
Yes
External Depth
157.5mm
External Width
110mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
●Control Circuit Terminals Specifications
●Mode Selector
RS-485 Communication/Operator Selector (S7)
Select the mode according to the option connected to the communications connector.
When using the 3G3AX-OP01 supplied with the Inverter, it is available regardless of the switch condition.
Emergency shutoff selector (S8)
Use this selector to enable the emergency shutoff input function.
* The multi-function input terminal 3 is switched to a terminal for emergency shutoff input, and the allocation of other multi-function input terminals is also changed
Input signal
Monitor
signal
Frequency
reference
input
Output signal
Relay output
signal
S7
S8
automatically. Do not set to ON immoderately. For details, refer to "Emergency Shutoff Input Function".
Symbol
Symbol
RS-485 communication/
operator selector
Emergency shutoff
selector
Terminal
symbol
PSC
AM
MA
MB
MC
SC
FS
FV
FC
PC
S1
S2
S3
S4
S5
P1
FI
Name
Name
External power supply terminal for input signal (input)
...At sink logic
Internal power supply output terminal for input signal (output)
...At source logic
Multi-function input terminals S1 to S5
Select 5 functions among the 31 functions and allocate them
to from terminals S1 to S5.
The terminal allocation is changed automatically when the
emergency shutoff function is used.
Input signal common
Analog frequency monitor/Analog output current monitor
Frequency reference power supply
Voltage frequency reference signal
Current frequency reference signal
Frequency reference common
Multi-function output terminal
Select the status of the Inverter and allocate it to terminal P1.
Output signal common
Analog
output
AM
485
OPE [Default]
ON
OFF
[Default]
FS FV FI FC S5 S4 S3 S2 S1 SC
Terminal name and function
Status
Status
Analog
input
MB
MA
RS485 Modbus communication
Digital Operator (Option: 3G3AX-OP1)
Emergency shutoff input enabled
Normal
MC
Simple, Compact Inverters SYSDRIVE
Relay
output
MB MA MC
Description
Description
Logic input
*
Forward/Stop
Reverse/Stop
Fault reset
Emergency stop fault
Multi-step speed
reference 1
Analog frequency
monitor
Frequency arrival
signal at a constant
speed
Factory default relay settings
Under normal operation: MA-MC Closed
Under abnormal operation or power shutdown: MA-MC Open
PSC P24
Default setting
Logic output
---
---
---
---
---
---
---
Short-circuit bar
PC P 1
24 V DC ±10%
30 mA max.
24 V DC ±10%
100 mA max.
Contact input
Close: ON (Start)
Open: OFF (Stop)
Minimum ON time:
12 ms min.
10 V DC
10 mA max.
0 to 10 V DC
Input impedance 10 kΩ
When installing variable resistors at FS,
FV, and FC (1 to 2 kΩ)
4 to 20 mA DC
Input impedance 250 Ω
27 V DC
50 mA max.
JX
Series
Note
17