VZA42P2BAA Omron, VZA42P2BAA Datasheet - Page 15

INVERTER DRIVE, 2.2KW, 400VAC, 5.5A

VZA42P2BAA

Manufacturer Part Number
VZA42P2BAA
Description
INVERTER DRIVE, 2.2KW, 400VAC, 5.5A
Manufacturer
Omron
Datasheet

Specifications of VZA42P2BAA

Supply Voltage Range
380VAC To 480VAC
No. Of Phases
Three
Power Rating
2.2kW
Output Voltage Max
480V
Frequency Range
57Hz To 63Hz
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
CE, CUL, TUV, UL
External Depth
154mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A
Chokes
B Communication cards
C Accessories
D Computer software
V1000
3-Phase 200 VAC
Single-Phase 200
3-Phase 400 VAC
Types
Types
Type
A1000-FEV2102-RE
A1000-FEV2515-RE
A1000-FEV5045-RE
Line filters
Voltage
VAC
Model
A1000-CAVOP300-EE
A1000-CAVPC232-EE
SI-N3/V-OY
SI-P3/V-OY
SI-S3/V-OY
SI-T3/V-OY
JVOP-180
JVOP-181
PS-V10M
PS-V10S
CX-drive
Inverter
CX-One
20P1 / 20P2 / 20P4 / 20P7
40P7 / 41P5 / 42P2 / 43P0
Model
Model
Model
B0P1 / B0P2 / B0P4
Model VZA@
B0P7 / B1P5
21P5 / 22P2
25P5 / 27P5
40P2 / 40P4
45P5 / 47P5
4011 / 4015
B2P2
B4P0
24P0
44P0
2011
2015
Diameter
PROFIBUS-DP option card
USB converter / USB cable
21
25
50
Mechatrolink II option card
Remote operator cable
DeviceNet option card
Can open option card
LCD remote operator
24 VDC option board
PC connection cable
Computer software
Computer software
Description
Description
Description
A1000-FIV2010-SE
A1000-FIV2020-SE
A1000-FIV2030-SE
A1000-FIV2050-SE
A1000-FIV2080-SE
A1000-FIV2100-SE
A1000-FIV1010-SE
A1000-FIV1020-SE
A1000-FIV1030-SE
A1000-FIV1040-SE
A1000-FIV3005-SE
A1000-FIV3010-SE
A1000-FIV3020-SE
A1000-FIV3030-SE
A1000-FIV3050-SE
Reference
Recommended for motors below 2.2 KW
Recommended for motors below 15 KW
Recommended for motors below 45 KW
Line filter Schaffner
Rated current (A) Weight (kg)
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through DeviceNet communication with the
host controller.
output frequency, output current, or similar items through PROFIBUS-DP communication
with the host controller.
output frequency, output current, or similar items through CANopen communication with the
host controller.
output frequency, output current, or similar items through Mechatrolink II communication with
the host controller.
Description
Under development
Under development
10
20
30
10
20
30
40
10
15
5
24V DC control board power supply VZA-B/2/4 from 0.1 to 4 KW
24V DC control board power supply VZA-2/4 from 5.5 to 15 KW
USB converter unit with copy and backup function
3 meters cable for connecting remote operator
LCD Display operator with language support
0.75
0.7
0.9
1.0
0.5
0.7
1.0
1.1
0.5
1.0
Configuration and monitoring software tool
Configuration and monitoring software tool
RS232 PC tool connection cable
A1000-FIV2010-RE
A1000-FIV2020-RE
A1000-FIV2030-RE
A1000-FIV2060-RE
A1000-FIV2080-RE
A1000-FIV2100-RE
A1000-FIV1010-RE
A1000-FIV1020-RE
A1000-FIV1030-RE
A1000-FIV1040-RE
A1000-FIV3005-RE
A1000-FIV3010-RE
A1000-FIV3020-RE
A1000-FIV3030-RE
A1000-FIV3050-RE
Installation
Reference
Functions
Function
Line filter Rasmi
Rated current (A) Weight (kg)
100
10
20
30
58
80
10
20
30
40
10
20
29
48
5
0.8
1.1
1.3
2.4
4.2
0.6
1.0
1.1
1.1
1.1
1.3
2.1
2.9
-
-
15

Related parts for VZA42P2BAA