VZA42P2BAA Omron, VZA42P2BAA Datasheet - Page 3

INVERTER DRIVE, 2.2KW, 400VAC, 5.5A

VZA42P2BAA

Manufacturer Part Number
VZA42P2BAA
Description
INVERTER DRIVE, 2.2KW, 400VAC, 5.5A
Manufacturer
Omron
Datasheet

Specifications of VZA42P2BAA

Supply Voltage Range
380VAC To 480VAC
No. Of Phases
Three
Power Rating
2.2kW
Output Voltage Max
480V
Frequency Range
57Hz To 63Hz
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
CE, CUL, TUV, UL
External Depth
154mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Commom specifications
V1000
Specifications
Control methods
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Braking torque
(short term peak torque)
V/f Characteristics
Inputs signals
Output signals
Standard functions
Analogue inputs
Braking/acceleration times
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
Model number
VZA@
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
mand, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control circuit terminal
Following output signals are selectable (NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, speed
agree, frequency detection (output frequency <= or => set value), during overtorque detection, minor error, during baseblock,
Open-loop vector control, full-range automatic torque boost, slip compensation, 17-step speed operation (max.), restart after
reference bias/gain, MEMOBUS communications (RS-485/422, max. 115K bps), fault retry, speed search, frequency upper/
lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel,
operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
momentary power loss, DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency
contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock, speed search com-
Continous regenerative torque: Aprox 20% (125% with optional braking resistor, 10%ED, 10 s, braking transistor built itn)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is
Short-term average deceleration torque: 150% (up 1.5 kW), 100% (for 1.5 kW), 50% (for 2.2 kW), 20% (fof bigger size)
Normal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stall prevention during acceleration/deceleration and constant speed operation
Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)
Up to 9.8 m/s
Cooling fan is provided for 200 V, 0.75 kW (1HP) (3/single-phase)
Motor coasts to a stop at approx. 250% of inverter rated current
Sine wave PWM (V/f control, sensorless current vector control)
selection, mergency stop fault, emergency stop alarm, self test
-20 ºC..+60 ºC (short-term temperature during transportation)
Normal duty use: 120% rated output current for one minute
Heavy duty use: 150% rated output current for one minute
400 V, 1.5 kW (2HP) (3-phase), others are self-cooling
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Pulse train input, frequency setting value (selectable)
0..10 V (20 kΩ), 4..20 mA (250 Ω), 0..20 mA (250 Ω)
Indicates until the main circuit voltage reaches 50 V.
Analogue set value: 1/1000 of maximum frequency
PID control, energy-saving control, constant copy.
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
(approx. 150 V or less for single-phase series)
approx. 0.5 s or shorter, continuous operation
2
Optionally frequency, current or set value
at 10 to less than 20 Hz, Up to 6.37 m/s
Analogue set value: ±0.1% (25 ±10 ºC)
95% RH or less (without condensation)
Digital set value: ±0.01% (-10..+50 ºC)
data output through communication.
Possible to program any V/f pattern
Indoor (no corrosive gas, dust, etc.)
Electronic thermal overload relay
Protected by thermister
Error and status LED
Specifications
IP20, NEMA1
Max. 1000 m
0.01..6000 s
0.1..400 Hz
0.01 Hz
2
at 20 to 50 Hz
3