8536SAG12V02S SQUARE D, 8536SAG12V02S Datasheet

Magnetic Motor Starter

8536SAG12V02S

Manufacturer Part Number
8536SAG12V02S
Description
Magnetic Motor Starter
Manufacturer
SQUARE D
Datasheet

Specifications of 8536SAG12V02S

No. Of Phases
Three
Power Rating
2hp
Current Rating
9A
Peak Reflow Compatible (260 C)
No
Supply Voltage Max
460VAC
Control Voltage Max
120V
Leaded Process Compatible
No
Switch Function
3PST
Supply Voltage Range
110VAC To 120VAC
Rohs Compliant
No
Contact Rating
9A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Type S Contactors and Starters
Class 8536/8502/8736/8702/8810/8811/8812
CONTENTS
Description
Page
Magnetic Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Reversing Magnetic Starters and Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Motor Starters Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39

Related parts for 8536SAG12V02S

8536SAG12V02S Summary of contents

Page 1

... Type S Contactors and Starters Class 8536/8502/8736/8702/8810/8811/8812 CONTENTS Description Magnetic Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Reversing Magnetic Starters and Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Motor Starters Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Page ...

Page 2

... Selection – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Selection – Class 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 Application Data – Class 8502, 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16 Approximate Dimensions, Shipping Weights – Class 8502, 8536 . . . . 17-22 Application Data – Class 8502 Vacuum Contactors Selection and Pricing – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 © 1998 Square D All Rights Reserved 1 ...

Page 3

... To order Type S starters with solid state overload relays, see Factory Modification (FORMS). Bimetallic overload relays are also available for Sizes 0-6. Ambient Compensated and Non- compensated versions are supplied with manual © 1998 Square D All Rights Reserved 5/98 ...

Page 4

... Type S contactors. See Page 15 for maximum number of auxiliary units and Form designations for factory installed auxiliary contacts. Type S Accessories Additional accessories such as power poles, pneumatic timer attachments, and cover mounted control stations are available as factory or field modifications. © 1998 Square D All Rights Reserved 3 ...

Page 5

... VO6 550 VO7 Specify V99 Catalog Number Class Type Coil Form(s) Voltage Code 8502 SBG2 VO2 P1S © 1998 Square D All Rights Reserved NEMA Type 1 General Open Type t Purpose Coil Voltage Enclosure Type Type 120 SAO12V02S SAG12V02S 208 SAO12V08 SAG12V08 240 ...

Page 6

... Class 3218-03 How to Order: To Order Specify: • Class Number Class • Type Number • Coil Voltage Code • Form(s) © 1998 Square D All Rights Reserved Selection – Class 8502 NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure ® SPIN TOP Type ...

Page 7

... Separate Controlj 200 40 135 230 50 460 100 575 100 © 1998 Square D All Rights Reserved NEMA Type 1 General Open Type t Purpose Coil Voltage Enclosure Type Type 120 SBO5V02 SBG5V02 240 SBO5V03 SBG5V03 120 SCO5V02 SCG5V02 240 ...

Page 8

... Field Office 480 600 120 208 Consult Local Square D 240 . . . Field Office 480 600 © 1998 Square D All Rights Reserved Selection – Class 8502 NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure ® SPIN TOP Cast Type Type Aluminum SBT45V02 ...

Page 9

... Specify V99 Catalog Number Class Type Coil Form(s) Voltage Code 8536 SBA2 VO2 P1S © 1998 Square D All Rights Reserved NEMA Type 4 & 4X NEMA Type 4X Watertight, Dusttight Watertight, Dusttight, Brushed Stainless Corrosion-Resistant Steel Enclosure Glass-Polyester (Size 0-5)f Enclosure Type Type Use Size 0 ...

Page 10

... How to Order: To Order Specify: • Class Number Class • Type Number • Coil Voltage Code • Form(s) © 1998 Square D All Rights Reserved Selection – Class 8536 NEMA Type 12/3Rk NEMA Type 9 Dusttight & Driptight Hazardous Locations Industrial Use Class II, Groups E, F, & G Enclosure ® ...

Page 11

... Specify V99 Catalog Number Class Type Coil Form(s) Voltage Code 8536 SCG1 VO2 P1 © 1998 Square D All Rights Reserved NEMA Type 4X NEMA Type 4 & 4X Watertight, Dusttight, Watertight, Dusttight Corrosion-Resistant Brushed Stainless Glass-Polyester Steel Enclosure Enclosure Type Type Use Size 0 Use Size 0 ...

Page 12

... How to Order: To Order Specify: • Class Number Class • Type Number • Coil Voltage Code • Form(s) © 1998 Square D All Rights Reserved Selection – Class 8536 NEMA Type 12/3Rf NEMA Type 9 Dusttight & Driptight Hazardous Locations Industrial Use Class II, Groups E, F, & G Enclosure ® ...

Page 13

... Voltage Dimensions ........................................................................... Pages 17-20 Code Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 VO3 P1 Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701 © 1998 Square D All Rights Reserved Coil Voltage 120 208 240 480 600 120 ...

Page 14

... The motor ratings in the above table are NEMA standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in the table below. Motors having code letters occurring later in the alphabet may require a larger controller. Consult local Square D field office. ...

Page 15

... Square D All Rights Reserved Maintenance of Equipment Class 9998 Repair Parts Kits are available for all Class 8502 contactors and Class 8536 starters. Service bulletins with a complete list of replaceable parts are supplied with all enclosed devices. Separate bulletins can be ordered and are listed along with the appropriate contact parts kit ...

Page 16

... X30 1 X31 0 X40 © 1998 Square D All Rights Reserved Application Data – Class 8502, 8536 Control Circuit Transformers Class 9070 Type T machine tool control transformers are normally used when it is necessary to provide a lower voltage to the control circuit. This transformer with fused protection may be ordered from the factory by specifying Form F4T ...

Page 17

... Size 6 and 7 devices have an additional N.C. auxiliary contact which is wired in the coil control circuit. DO NOT USE THIS N.C. CONTACT FOR ANY OTHER PURPOSE. © 1998 Square D All Rights Reserved Class 9070 Type 50 Hertz 220/440-110 EO3S2A . . . ...

Page 18

... Square D All Rights Reserved Class 8536 Open Type RESET D E Figure 1.63 41 1.63 41 ...

Page 19

... Same as Standard NEMA 1 Dimensions, see above. 18.16 461 29.16 741 9.25 235 9.25 Same as Standard NEMA 1 Dimensions, see above. ⁄ 16 Form F4T is supplied as standard. Refer to Page 16. © 1998 Square D All Rights Reserved Figure ...

Page 20

... Same as Standard NEMA Type 4 dimensions, see above. SFW SEW 2-3 See as Standard NEMA Type 4 dimensions, see above. SFW Same as Standard NEMA Type 4 dimensions, see above. Form F4T is supplied as standard. Refer to Page 16. All © 1998 Square D All Rights Reserved Top Bot. & Bot ...

Page 21

... SEE 2-4 12.84 326 9.72 247 24.16 614 22.25 565 9.00 4 SFE 2-4 15.84 402 9.72 247 34.16 868 32.25 819 12.00 305 1.88 48 NOTE: Devices with Form F4T may use larger enclosure. Consult local Square D Field Office for dimensions Size 2 ...

Page 22

... Square D All Rights Reserved ® , Cast Aluminum Top View 7.50 .25 191 R 6 (2) "L" Pipe F G Tap Top and Bottom Threaded Cover ...

Page 23

... SEH All 326 642 219 35 37 254 12.84 40.28 9.13 1.38 1.44 10.00 SFH All 326 1023 232 35 37 254 © 1998 Square D All Rights Reserved 1.56 3.25 12.00 .38 3.56 12. 305 10 90 311 1.56 5.00 15.00 .50 3.56 15.38 ...

Page 24

... Max. Allowable Interrupting Impulse Voltage 40ms) General Information Class 8502 Type W non-reversing vacuum contactors are a new addition to the Square D line of contactors. These contactors are used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W vacuum contactors are designed for operation at 600 Volts, 50/60 Hertz ...

Page 25

... Key Holes 1 2 .33 Slot 8 (2 Places) .58 6.75 171 15 3.72 94 Side View © 1998 Square D All Rights Reserved NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 4 & 5 only) Type WFW3V02S WFW3V03 WFW3V02S WFW3V06 WFW3V07 WGW3V02S WGW3V03 WGW3V02S WGW3V06 WGW3V07 WHW3V02S ...

Page 26

... Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30 Selection – Class 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-32 Application Data – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Approximate Dimensions – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . 34-36 Application Data, Selection – Class 8702 Vacuum Contactor . . . . . . . . . . 37 Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 © 1998 Square D All Rights Reserved 25 ...

Page 27

... Square D All Rights Reserved 5/98 ...

Page 28

... NEMA Type 4 only. Also, NEMA Type 12 devices are available UL Listed for use in Class II, Division 2, Group G and Class III, Divisions 1 and 2 locations. Request Form G21, no additional charge. Separate enclosures are available, see Class 9991. © 1998 Square D All Rights Reserved 27 ...

Page 29

... Form designations for factory installed auxiliary contacts. See Class 9999 for auxiliary contact kits for field installation. Type S Accessories Additional accessories such as power poles, pneumatic timer attachments, and cover mounted control stations are available as factory or field modifications. © 1998 Square D All Rights Reserved 5/98 ...

Page 30

... Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701 VO2 P1S Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701 © 1998 Square D All Rights Reserved Selection – Class 8702 NEMA Type 4 & 4X NEMA Type 7 & 9 Watertight, Dusttight ...

Page 31

... How to Order: To Order Specify: • Class Number Class • Type Number • Coil Voltage Code • Form(s) 8702 © 1998 Square D All Rights Reserved NEMA Type 4 & 4X NEMA Type 7 & 9 Watertight, Hazardous Locations Dusttight Class I, Groups C & D Brushed Stainless Class II, Groups E, F & G ...

Page 32

... Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701 VO2 P1S Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701 © 1998 Square D All Rights Reserved Selection – Class 8736 NEMA Type 7 & 9 NEMA Type 12 Hazardous Locations Dusttight & Driptight Class I, Groups C & ...

Page 33

... How to Order: To Order Specify: • Class Number Class • Type Number • Coil Voltage Code • Form(s) 8736 © 1998 Square D All Rights Reserved NEMA Type 4 & 4X NEMA Type 7 & 9 Watertight, Hazardous Locations Dusttight Class I, Groups C & D Brushed Stainless Class II, Groups E, F & G ...

Page 34

... X0110 X0101 X2000 X2010 X2001 X1100 X1110 X1101 X0200 X0210 X0201 © 1998 Square D All Rights Reserved Maximum number of auxiliary units on each No. of Poles contactor, forward or of Basic reverse, (in addition to Contactor internal holding circuit and interlocking contacts). 2 single circuit auxiliary contacts ...

Page 35

... Square D All Rights Reserved RESET .47 4.34 .19 5.50 .91 12 110 5 140 23 .47 4.34 .19 5.50 .91 12 110 ...

Page 36

... Floor Mounting 5 34.50 876 93.00 2362 23.50 597 © 1998 Square D All Rights Reserved 1.50 H ...

Page 37

... Square D All Rights Reserved Fig 16.88 429 9.78 248 22.75 578 10.13 257 24.63 626 11.94 303 27.00 686 17.88 454 25 ...

Page 38

... Contactor use. GENERAL INFORMATION Class 8702 Type W reversing vacuum contactors are a new addition to the Square D line of contactors. These reversing contactors are used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W reversing vacuum contactors are designed for operation at 600 Volts, 50/60 Hertz ...

Page 39

... Class 8702 WH © 1998 Square D All Rights Reserved Suffix Number (Complete Coil Number Consists of Class and Type Followed by Suffix Number) 120 Volts 240 Volts 480 Volts 110 Volts 220 Volts 440 Volts 120 240 ...

Page 40

... Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . 47 Application Data for Types SB-SJ – Class 8810, 8811, 8812 . . . . . . . . . . 48 Dimensions – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . 50-51 Disconnect Switch or Circuit Breaker Type – Class 8810, 8811, 8812 . . . 52 © 1998 Square D All Rights Reserved 39 ...

Page 41

... The speed of a squirrel cage motor is directly proportional to the power supply frequency and inversely proportional to the number of poles in the stator winding. With the frequency constant, motor speed is determined by the number of poles. (120) (Frequency) (RPM) Speed = No. of Poles Where: Horsepower = T = Torque 5250 S = Speed in RPM © 1998 Square D All Rights Reserved 5/98 ...

Page 42

... Form R10 should be included in the form designation of the reversing multispeed starters. This provides second delay in the transfer of the direction of the motor, and can help prevent damage which could result from plugging. © 1998 Square D All Rights Reserved 41 ...

Page 43

... NEMA Type 12 enclosures may be field modified for outdoor applications. j NEMA Type 4X enclosures available; consult local Square D field office. c Addition of forms to standard NEMA Type 7 and 9 enclosed devices is limited. Consult local Square D field office. k 380 Volts, 50 Hertz – above type numbers will apply to starters for 380 volt, 50 hertz but the ...

Page 44

... All three phase two speed magnetic starters require six (6) thermal units, three per speed. Use VO6 P1S nameplate FLC’s (Full Load Currents) from motor nameplate. © 1998 Square D All Rights Reserved Reversing In Both Speeds Dusttight and General Driptight Industrial ...

Page 45

... Catalog Number Class Type Coil Form(s) Voltage Code 8810 SCO8 VO6 P1S © 1998 Square D All Rights Reserved For Consequent Pole Motors 460-575 V Type 3 SBW-51 ⁄ ⁄ SCW- SDW-51 40 SEW- SBW-52 10 SCW-52 25 SDW-52 50 SEW-52 100 . . . For Consequent Pole Motors ...

Page 46

... Square D All Rights Reserved No. No. No Cont. Cont. Cont OL-1 OL-2 OL-3 Figure 2 Contactor, overload and external electrical interlock positions Overload No. 3 Contactor Relay Size and Poles Position NEMA Size 1 NEMA Size 2 See Fig. 3 No. of Poles No. of Poles 3 ...

Page 47

... SFG-3 Catalog Number Class Type Coil Form(s) Voltage Code 8810 SCO8 VO6 P1S © 1998 Square D All Rights Reserved Watertight and Dusttight and Driptight Dusttight Enclosure Industrial Use Enclosure (Stainless Steel) NEMA Type 12 NEMA Type 4 (Type 3 and 3R)j Type Type SBW-1 ...

Page 48

... Square D All Rights Reserved 1 N.O. 1 N.C. 2 N.O. 1 N.O.-1 N.C. X02 X03 X05 X06 X12 X13 X15 X16 X22 X23 X25 X26 X32 X33 X35 X36 X52 ...

Page 49

... Type SM-4 for Size Type SM-9 for Size 2 Type SM-11 for Size 3 Type SM-13 for Size 4 © 1998 Square D All Rights Reserved three pole contactors, a different version for four or five pole contactors. When adding a power pole to an existing three pole reversing contactor, a new mechanical interlock must also be installed ...

Page 50

... Square D All Rights Reserved Dimensions – Class 8810, 8811, 8812 . . RESET RESET Provision for .31 (4) Dia. Mounting Screws 8 Figure 2 Class 8810, Sizes 3 & ...

Page 51

... Floor Mount Consult Square D © 1998 Square D All Rights Reserved (4) H Dia. Mounting Holes 248 1 ...

Page 52

... Std. & Form Y79-1 SCR- & 4 16.13 410 50.50 1283 85.00 2159 20.25 514 9.13 232 8.63 219 32.75 832 4.50 114 30.00 762 12.00 305 2.63 67 Forms T & Y79-1 For Sizes 3, 4 and 5 consult Square D field office. 5/ ...

Page 53

... IN mm 24.75 629 3.30 84 2.56 65 31.25 794 3.30 84 3.08 78 Handle A Swing (4) .31 Dia. Mtg. Holes 8 (For Size 0, 1, & 2) Cover Open Figure 2 NEMA Type 4 Enclosure © 1998 Square D All Rights Reserved 2.31 1.06 3.30 2.19 1.25 . 2.63 1.33 3.30 2.22 1.27 . ...

Page 54

... Knightdale, NC 27545-9023 (919) 266-3671 registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. MOTOR LOGIC is a trademark of Square D Company. Spin Top, Square D and are registered trademarks of Square D Company. Catalog No. 8502CT9701 May 1998 © 1998 Square D All Rights Reserved. ...

Related keywords