200557-002S REDINGTON COUNTERS, 200557-002S Datasheet

AC Power Module

200557-002S

Manufacturer Part Number
200557-002S
Description
AC Power Module
Manufacturer
REDINGTON COUNTERS
Datasheet

Specifications of 200557-002S

Signal Input Type
Count/Analog
Output Voltage Max
90VAC
Output Voltage Min
-250VAC
Features
Also Outputs +12VDC For Base Unit And Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Description
The Model 88 is a family of LCD Indicators/Controllers, with eight 7-segment digits that are 0.35” [9mm] in height. The standard display is a backlit LCD,
providing red characters on a dark background. An optional reflective LCD with dark characters on a light background is available. Unit programming
is accomplished using four front-panel switches, or programming can be done using the optional serial data interface and dedicated PC-based software
(Redi-Ware), which is available from Redington free of charge. Upon power up, the Indicator/Controller performs internal diagnostics and flashes all seg-
ments of the display “ON” and “OFF” several times. The Indicator/Controller then configures itself per previous programming, loads the internal Counters
and Timers with their values prior to power down, and begins normal operation.
The Model 88 Indicator/Counter is capable of receiving counts and/or analog inputs, processing those inputs in a number of different selectable ways,
and then providing outputs in several formats. Base units, i.e. #8800-0000, 8802-0000, or similar units can be programmed for Elapsed Time, Rate,
Preset Count/Time, count Add/Sub, or Quadrature. The count inputs can be prescaled from -9.9999 to 99.9999. On the 8802 units, the prescale can be
further multiplied by 10
be either prescaled count per hours (PPH) or per minute (rpm). The two independent control outputs are open-collector (NPN) outputs that can be con-
trolled by either count inputs, time, rate, the analog input, or combinations of these inputs. Based on two inputs, the indicator is capable of displaying two
counts, a rate indicator and an elapsed time at the same time. The base unit provides the display, programming, and processing functions for the final
configuration as well as the counter I/0 function. I/0 functions and installed modules are available that allow the user to configure complex functions into
a small enclosure. Other models add analog input/output functions to the base unit, and serial communication functions, which supports RS232/RS422/
RS485, providing the user with a broad selection of configurations.
Each Model 88 base unit is normally powered from a DC voltage of +10V to + 32 V. However, an AC power supply module # 200557-002S can be at-
tached to the rear of the unit that converts +90VAC to +250VAC, to +12VDC, which can be used to power the Model 88 and an external sensor. Another
module, 200557-001S, can be added that converts the discrete outputs of the Model 88 base unit to relay contacts.
Features
Specifications
Display:
Annunciators:
Programming:
Available
Functions:
Dual up counting
Preset of time, rate or count
Directional counting
1,2,4x quadrature
Add/add counting
Add/subtract counting
Rate indication on count inputs
Analog ranges: 0 to 10 VDC or 4 to 20 mA
Prescaling of analog inputs and counts
Elapsed timer function available for all modes of operation
NEMA 4X/IP56 sealed panel
UL, cUL Recognized, CE Compliant UL file # E19514
Model 88
LCD, 8 digits, 0.35” [9mm] negative image transmis-
sive red or positive image reflective display. In the
negative count mode the display will be 7 digits with a
“-” sign. (Reflective display recommended in sunlight)
A, B, R, 1, 2 ANLG, LOCK, HZ, RPM, HRS, SEC.
0.039’’ [1mm]
Programming is accomplished through the front panel
switches or by serial data interface and dedicated PC
software, supplied by Redington Counters, Inc.
Totalizer
Directional Counting
Rate/Count
-3
. Rate can be displayed as the prescaled rate of the count per seconds (Hz) or per minute (rpm). On the 8802 units, the rate can
Electronic
www.redingtoncounters.com
Options
Predetermining
Functions:
LCD Programmable Indicator/Controller
Relay Module 200557-001S
Serial Comm. (RS232, RS422, RS485)
Analog input/outputs
Display color
AC Power Module 200557-002S
2 form C, 5 amp relays
+90 VAC to +285 VAC, 50/60 Hz (unit is
normally powered from +10 VDC to +32 VDC)
Three different quadrature resolutions
Add-Add
Add-Subtract
Dual Count
Elapsed Time
Analog Input
Predetermining
Preset units provide two discrete outputs which can
be controlled as a function of count, rate, elapsed
time, or analog input. Each control output can be set
by any of the four functions and reset by the same
or a different function. For example, control output
1 could be set when a specific count is reached and
reset when an analog input level is reached.
85

Related parts for 200557-002S

200557-002S Summary of contents

Page 1

... RS485, providing the user with a broad selection of configurations. Each Model 88 base unit is normally powered from a DC voltage of +10V However power supply module # 200557-002S can be at- tached to the rear of the unit that converts +90VAC to +250VAC, to +12VDC, which can be used to power the Model 88 and an external sensor. Another module, 200557-001S, can be added that converts the discrete outputs of the Model 88 base unit to relay contacts ...

Page 2

... Power Requirements: Base unit: +10VDC TO +32VDC @ 50mA max. Relay Module: Model 200557-001S; +10VDC to +32VDC @ 50mA, max. AC Power Supply: Model 200557-002S; +90VAC to +250 VAC 50/ max. Memory: Nonvolatile EEPROM retains all program parameters and values when power is removed. EEPROM pro- vides 20 year data retention. ...

Page 3

... Reflective, 10-30VDC, Analog Input, Expanded Prescale, PPH Rate, Serial Comm ACCESSORIES 200557-001S Relay module 2 form C relays 200557-002S AC Voltage module, +90VAC to +250VAC also outputs +12VDC for base unit & sensor Note: Reflective display is recommended for applications that will be exposed to direct sunlight * All parts are normally in factory stock ...

Page 4

Model 88 Models Description For Models and Descriptions see the Ordering Information section Dimensions 2.96 [75.2] Panel Cutout 2.63’’ to 2.605’’ x 1.28’’ to 1.26’’ [66.8 to 66.2 x 32.5 to 32.0] Applications Batching Flow and level control 88 Electronic ...