MCETH CARLO GAVAZZI, MCETH Datasheet

ETHERNET PORT MODULE

MCETH

Manufacturer Part Number
MCETH
Description
ETHERNET PORT MODULE
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of MCETH

Accessory Type
Ethernet Port Module
For Use With
WM3096 Type Smart Modular Power Analyzer

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCETH
Manufacturer:
Carlo gavazzi
Quantity:
500
Energy Management
Smart Modular Power Analyzer
Type WM30 96
(*) as standard.
(**) on request.
Product Description
Type Selection
Range codes
AV4:
AV5:
AV6:
AV7:
Specifications are subject to change without notice
• Front protection degree: IP65, NEMA4X, NEMA12
• One RS232 or RS485 port (on request)
• Communication protocol: MODBUS-RTU, iFIX SCADA
• MODBUS TCP/IP Ethernet port (on request)
• BACNet-IP over Ethernet port (on request)
• Up to 2 digital outputs (pulse, alarm, remote control)
• Up to 4 freely configurable virtual alarms
• Up to 2 analogue outputs (+20mA, +10VDC) (on request)
Three-phase smart power
analyzer
advanced
system
displaying.
recommended
measurement of the main
electrical variables. WM30 is
based on a modular housing
for panel mounting with IP65
(front) protection degree.
Moreover, the analyzer can
compatibility
(on request)
400/690V
1(2)A (**)
V
V
400/690V
5(6)A (*)
V
V
100/208V
5(6)A (**)
V
V
100/208V
1(2)A (**)
V
V
LN
LL
LN
LL
LN
LL
LN
LL
: 277V to 830V
: 277V to 830V
: 70V to 250V
: 70V to 250V
: 160V to 480V
: 160V to 480V
: 40V to 144V
: 40V to 144V
and
with
configuration
LL
LL
LL
LL
LCD
Particularly
AC
AC
AC
AC
for
built-in
LL
LL
LN
LN
LL
LL
LN
LN
data
the
be provided with digital
outputs that can be either
for pulse proportional to the
active and reactive energy
being measured or/and for
alarm
instrument can be equipped
with the following modules:
RS485/RS232,
BACNet-IP communication
ports,
outputs.
System
3:
Options
XX:
balanced and
unbalanced load:
3-phase, 4-wire;
3-phase, 3-wire;
2-phase, 3-wire;
1-phase, 2-wire (*)
none
pulse and
outputs.
WM30 96 DS 271109
Ethernet,
alarm
The
How to order
Model
Range code
System
Power Supply
A Outputs
B Outputs
Communication
Option
Power supply
H:
L:
Communication
XX:
S1:
E2:
BI:
• Class 0.5 (kWh) according to
• Class C (kWh) according to EN50470-3
• Class 2 (kvarh) according to EN62053-23
• Accuracy ±0.2% RDG (current/voltage)
• Instantaneous variables readout: 4x4 DGT
• Energies readout: 9+1 DGT
• System variables: VLL, VLN, A, VA, W, var, PF, Hz,
• Single phase variables: VLL, VLN, AL, An (calculated),
• Both system and single phase variables with average
• Harmonic analysis (FFT) up to the 32nd harmonic
• Energy measurements (imported/exported): total and
• Energy measurements according to ANSI C12.20 CA
• Run hours counter (8+2 DGT)
• Real time clock function
• Application adaptable display and programming
• Universal power supply: 18 to 60VAC/DC, 90 to
• Front dimensions: 96x96 mm
EN62053-22
Phase-sequence-asymmetry-loss.
VA, W, var, PF
and max calculation
(current and voltage)
partial kWh and kvarh
0.5, ANSI C12.1 (revenue grade)
procedure (Easyprog function)
260AC/VDC
90 to 260V AC/DC
(48 to 62Hz) (*)
18 to 60VAC/DC
(48 to 62Hz) (**)
none (*)
RS485/RS232 port (*)
Ethernet / Internet
port (**)
BACNet (IP) over
Ethernet (**)
WM30-96 AV5 3 H R2 A2 S1 XX
B Outputs
XX:
A2:
V2:
A Outputs
XX:
O2:
R2:
none (*)
Dual channel 20mA
DC output (*)
Dual channel 10V
DC output (*)
none (*)
Dual channel static
output (*)
Dual channel relay
output (*)
1

Related parts for MCETH

MCETH Summary of contents

Page 1

Energy Management Smart Modular Power Analyzer Type WM30 96 • Front protection degree: IP65, NEMA4X, NEMA12 • One RS232 or RS485 port (on request) • Communication protocol: MODBUS-RTU, iFIX SCADA compatibility • MODBUS TCP/IP Ethernet port (on request) • BACNet-IP ...

Page 2

WM30 96 Position of modules and combination Ref Description 1 2 WM30 base provided with display, power supply, measuring inputs Dual relay output (SPDT) 6 Dual static output (AC/DC Opto-Mos) 7 Dual analogue output (+20mADC) 8 Dual ...

Page 3

WM30 96 Input specifications Rated inputs System type phase Current type Galvanic insulation by means of built-in CT’s Current range (by CT) AV5 and AV6: 5(6)A AV4 and AV7: 1(2)A Voltage (by direct connection or VT/PT) ...

Page 4

WM30 96 Output specifications Relay outputs (M O R2) Physical outputs 2 (max. one module per instrument) Purpose For either alarm output or pulse output Type Relay, SPDT type AC 1-5A @ 250VAC; AC 15-1.5A @ 250VAC DC 12-5A @ ...

Page 5

WM30 96 Output specifications (cont.) Signal retransmission The signal output can be connected to any instantaneous variable available in the table “List of the variables that can be connected to”. Scaling factor Programmable within the whole range of retransmission; it ...

Page 6

WM30 96 Output specifications (cont.) reading purpose and for programming parameter purpose) IP configuration Static IP / Netmask / Default gateway BACnet-IP Port Fixed: BAC0h Modbus Port Selectable (default 502) Client connections Modbus only: max 5 simultaneously Connections RJ45 10/100 ...

Page 7

WM30 96 Display, LED’s and commands ≤ 100 ms Display refresh time Display 4 lines, 4-DGT, 1 lines, 10-DGT Type LCD, single colour backlight Digit dimensions 4-DGT: h 9.5mm; 10-DGT: h 6.0mm Instantaneous variables read-out 4-DGT Energies variables read-out Imported ...

Page 8

WM30 96 Main functions (cont.) Filter Operating range Selectable from 0 to 100% of the input display scale Filtering coefficient Selectable from Filter action Measurements, analogue signal retransmission, serial communication (fundamental variables and their ...

Page 9

WM30 96 General specifications (cont.) supply input: 1kV Radio frequency suppression According to CISPR 22 Standard compliance Safety IEC60664, IEC61010-1 EN60664, EN61010-1 EN62052-11. Metrology EN62053-21, EN62053-23, EN50470-3. MID ”annex MI-003” Pulse output DIN43864, IEC62053-31 Approvals CE, cULus “Listed” Connections Screw-type ...

Page 10

WM30 96 List of the variables that can be connected to: • Communication port (all listed variables) • Analogue outputs (all variables with the only exclusion of “energies” and “run hour counter” • Pulse outputs (only “energies”) • Alarm outputs ...

Page 11

WM30 96 List of selectable applications Description A Cost allocation B Cost control C Complex cost allocation D Solar E Complex cost and power analysis F Cost and power quality analysis G Advanced energy and power analysis for power generation ...

Page 12

WM30 96 Additional available information on the display No Line 2 Line 1 1 Lot n. (text) xxxx Yr. (text) xx Conn. xxx.x 2 (3ph.n/3ph/3ph./ CT.rA (text) 3ph.2/1ph/2ph) LED PULSE (text) xxxx kWh per 3 kWh pulse PULSE out1 xxxx ...

Page 13

WM30 96 Accuracy (According to EN50470-3 and EN62053-23) kWh, accuracy (RDG) depending on the current Percentage error limits for class index C +1% +0.5% 0% -1% -0.5% PF=1 0.05A (I ) 0.25A (I ) min tr 0.01A (I ) 0.05A ...

Page 14

WM30 96 Wiring diagrams Power Supply WM30 BACK-VIEW System type selection: 3-Ph.n 3-ph, 4-wire, unbalanced load Fig 3-CT connection System type selection: 3-Ph (cont.) 3-ph, 3-wire, ...

Page 15

WM30 96 Wiring diagrams System type selection: 3-Ph.1 3-ph, 3-wire, balanced load Fig 1-CT connections System type selection: 2-Ph 2-ph, 3-wire Fig ...

Page 16

WM30 96 Static, relay and analogue outputs wiring diagrams R2, modules Out 1 Out A2 V2, modules RS485 and RS232 wiring diagrams M C 485 232, module NOTE. RS485: additional ...

Page 17

WM30 96 Front panel description Dimensions and Panel cut-out Specifications are subject to change without notice 1. Key-pad To program the configuration parameters and scroll the variables on the display. 2. Display LCD-type with alphanumeric indications to: ...

Related keywords