LPAX0500 Red Lion Controls, LPAX0500 Datasheet

Multifunction Meter

LPAX0500

Manufacturer Part Number
LPAX0500
Description
Multifunction Meter
Manufacturer
Red Lion Controls
Type
Multi-Functionr
Datasheet

Specifications of LPAX0500

No. Of Digits / Alpha
5
Panel Cutout Height
3.63"
Panel Cutout Width
9.29"
Signal Input Type
Current, Process, Strain Gage, Thermocouple, Voltage
Connection Type
Cage-Clamp
Cut Out, Panel
9.29×3.63 "
Digit Height
4
Dimensions
10"L×4.77"W×4.75"H
Display Digit Height
1.5 "
Display Type
LED
Function
Ammeter/Process/Resistance/Strain Gage/Temperature/Voltage
Material, Casing
Steel
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
-19999 to 99999
Termination
Cage Clamp
Voltage, Input
85 to 250 VAC
Voltage, Supply
85 to 250 VAC/11 to 36 VDC or 24 VAC
Sealing
NEMA 4/IP65
Character Size
1.5"
Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Red Lion MPAXD000, MPAXH000, MPAXP000 And MPAXT000 MPAX Modules
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL LPAX- 5 DIGIT LARGE PAX DISPLAY FOR ANALOG INPUTS
GENERAL DESCRIPTION
offering the plant floor or production area a large visual display of their current
status. Whether your measurement is temperature, weight, or flow, the LPAX
can satisfy your requirement. With the use of a units label and backlighting, the
display can be tailored to show the actual engineering unit, which further
enhances the display. This LPAX display accepts various analog inputs through
the use of input modules (MPAX) which allow the unit to adapt to most any
application. The MPAX Modules offer the same features as our highly
successful PAX Series Panel Meters. Additional plug-in option cards can add
alarms, analog output, and communication/bus capabilities, making the LPAX a
truly Intelligent Panel Meter.
SAFETY SUMMARY
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected
to it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
DIMENSIONS In inches (mm)
The LPAX Display is a versatile display that can increase productivity by
All safety regulations, local codes and instructions that appear in this and
installation and operation of the unit.
Read complete instructions prior to
CAUTION: Risk of Danger.
4
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
The protective conductor terminal is bonded to conductive
CAUTION: Risk of electric shock.
1
SPECIFICATIONS
1. DISPLAY: 1.5" (38 mm) Red LED
2. POWER REQUIREMENTS:
3. INPUT: Accepts analog input modules, see “Selecting your display
4. ANNUNCIATORS:
5. KEYPAD: Five tactile membrane switches integrated into the front panel
6. CERTIFICATIONS AND COMPLIANCES:
! LARGE LED DISPLAY READABLE TO 70 FEET
! VARIOUS ANALOG INPUT MODULES;
! ALARMS, ANALOG OUTPUT, AND COMMUNICATION
! CUSTOM UNITS LABEL WITH BACKLIGHT
! PROGRAMMABLE USER INPUTS
! PROGRAMMABLE FUNCTION KEYS
! UNIVERSAL AC/DC POWERED MODELS
! CRIMSON PROGRAMMING SOFTWARE
! NEMA 4/IP65
Additional specifications, wiring, programming, and information for the
individual MPAX models are contained in the corresponding standard PAX
literature. This PAX literature is shipped with the ordered MPAX model.
5-Digit: (-19999 to 99999)
AC Modules: 85 to 250 VAC, 50/60 Hz, 18 VA
DC Modules: 11 to 36 VDC or 24 VAC ±10%, 50/60 Hz, 14 W
components.”
LPAX0500: MAX, MIN, TOT, SP1, SP2, SP3, and SP4
Optional units label with backlight
UL Recognized Component, File #E179259, UL61010A-1, CSA 22.2 No. 1010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4 Enclosure rating (Face only), UL50
IECEE CB Scheme Test Certificate #US/8843/UL
ELECTROMAGNETIC COMPATIBILITY
Recognized to US and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
CB Scheme Test Report #04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
EMC specifications determined by the MPAX module.
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
DC VOLTAGE AND CURRENT
PROCESS SIGNALS
TRUE RMS VOLTAGE AND CURRENT
THERMOCOUPLE OR RTD
STRAIN GAGE/BRIDGE
PANEL CUT-OUT
Bulletin No. LPAX-D
Drawing No. LP0489
Released 12/05

Related parts for LPAX0500

LPAX0500 Summary of contents

Page 1

... DC Modules VDC or 24 VAC ±10%, 50/60 Hz INPUT: Accepts analog input modules, see “Selecting your display components.” 4. ANNUNCIATORS: LPAX0500: MAX, MIN, TOT, SP1, SP2, SP3, and SP4 Optional units label with backlight 5. KEYPAD: Five tactile membrane switches integrated into the front panel 6. CERTIFICATIONS AND COMPLIANCES: UL Recognized Component, File #E179259, UL61010A-1, CSA 22 ...

Page 2

... LPAX meter. The LPAX program can then be saved file for future use. A PAX serial plug-in card is required to program the meter using the software MPAX MODULES LPAX DISPLAYS VDC/ 24 VAC MPAXD010 LPAX0500 MPAXP010 LPAX0500 MPAXT010 LPAX0500 MPAXS010 LPAX0500 N/A LPAX0500 ® based program that allows configuration of the ...

Page 3

ASSEMBLING THE DISPLAY CAUTION: The MPAX main circuit board and the option cards contain static sensitive components. Before handling the module or the cards, discharge static charges from your body by touching a grounded bare metal object. Handle the ...

Page 4

... Extended Modbus Communications Card with Dual RJ11 Connector Profibus-DP Communications Card Analog Output Card Custom Units Label Crimson 2 PC Configuration Software for Windows 98, ME, 2000 and XP NEMA 4 Enclosure for LPAX Shroud for LPAX Mounting Bracket for LPAX PART NUMBERS LPAX0500 MPAXD000 MPAXD010 MPAXP000 MPAXP010 MPAXT000 MPAXT010 MPAXH000 MPAXS000 ...

Related keywords