06524 Simpson, 06524 Datasheet

Current Meter

06524

Manufacturer Part Number
06524
Description
Current Meter
Manufacturer
Simpson
Datasheets

Specifications of 06524

Meter Function
DC Milliammeter
Meter Range
0mA To 20mA
Meter Size/dimensions
4.5 X 4.5 In.
Scale Length
100mm
Meter Shape
Square
External Height
4.5"
Display Accuracy ±
2%
Current Meter Range
0-20 MA
Equipment Type
DC Current Meter
Range
0 - 20
Size
4.50 in
Accuracy
+/-2 %
Barrel Size
2.81"
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Dimensions
• Clear acrylic window for wide angle
• Rugged black plastic case
• Black spade pointer for easy distant reading
• Optional behind-panel mounting bezel kit
1-1/2"-Model 1212, 1212T
1.76
visibility
.41
.53
.86
.55
1.50
DIA.
1.55
DIA.
(2) #8-32 STUDS
(4) #4-40 MTG. STUDS
MTG. HOLES- .128 DIA. DRILL THRU
.65
1.75
For more information, visit www.simpsonelectric.com
1.00
1.31
.12
.65
1.31
Specifications
Accuracy:
Movement:
Tracking:
Shielding:
Response Time:
Overload
(1 sec.):
Overload
(Continuous):
Repeatability:
Dial:
Resistance:
Operating
Temperature:
Case:
Pointer:
Scale Length:
Net Weight:
2-1/2" - Model 1287
+2% F.S. (Iron-Vane), +3 F.S. (Rectified)
Models 1212, 1212T: Small core magnet
Models 1247, 1347, 1349: Annular, rectifier
Models 1257, 1357, 1359: Iron-vane, magnetically
damped
+3%
Calibration is unaffected by magnetic panel mounting.
1.5 seconds maximum
10 times F.S.
1.5 times F.S.
2%: AC Current, DC Process
3%: AC Voltage, DC Voltage, Wattmeters
0.5%: DC Current
Sharp clear scale. Each dial arc is calibrated to track the
specific type of movement used.
+15% of meter impedance
-4°F to +149°F (-20°C to +65°C)
High density black plastic
Model 1212: Black lance;
All other models: Spade with black matte finish
Model 1212, 1212T: 1.50" (38.1mm);
Model 1227, 1227T, 1247, 1257: 2.3" (58.4mm)
Model 1327, 1327T, 1347, 1357, 1377: 3.14" (79.9mm);
Model 1329, 1329T, 1349, 1359, 1379: 3.93" (100mm)
Model 1212, 1212T: 2oz (0.06kg);
Model 1257: 4 oz. (0.11kg)
Model 1359: 5 oz. (0.14kg)
Model 1227, 1227T: 6oz (0.17kg)
Model 1327, 1327T, 1347: 8oz (0.23kg);
Model 1329, 1329T, 1349, 1377: 9oz (0.26kg)
Model 1379: 10 oz.( 0.28kg)

Related parts for 06524

06524 Summary of contents

Page 1

... DIA. (2) #8-32 STUDS (4) #4-40 MTG. STUDS MTG. HOLES- .128 DIA. DRILL THRU For more information, visit www.simpsonelectric.com Specifications Accuracy: +2% F.S. (Iron-Vane), +3 F.S. (Rectified) Movement: Models 1212, 1212T: Small core magnet Models 1247, 1347, 1349: Annular, rectifier Models 1257, 1357, 1359: Iron-vane, magnetically ...

Page 2

... Model 1379 4.70 For more information, visit www.simpsonelectric.com 4-1/2"-Model 1329, 1329T, 1349, 1359 (2) #1/4-28 STUD 4-1/2"-Model 1389 3-1/2"-Model 1327, 1327T, 1347, 1357 4.70 4.70 ...

Page 3

... Available on special order * These meters require use of an external current transformer from page C5. For more information, visit www.simpsonelectric.com , AC Voltmeters 4-1/2” 3-1/2” Range Model 1359 Model 1357 0-5 06625 06665 ...

Page 4

... Model 1327 Model 1329 0-50 06310 06470 50-0-50 06320 06480 <> Available on special order. 06330 06490 06340 06495 DC Voltmeters 06350 06502 06360 06524 06370 06530 Impedance (Ohms) @ 06380 06540 Range 06390 06550 0-5 06400 06560 06410 06570 0-8 06420 06580 ...

Related keywords