10760 Simpson, 10760 Datasheet - Page 11

Watt Meter

10760

Manufacturer Part Number
10760
Description
Watt Meter
Manufacturer
Simpson
Datasheets

Specifications of 10760

Meter Function
Watt
Meter Range
0W To 750W
Meter Size/dimensions
4.5 In.
Scale Length
89mm
Meter Shape
Rectangular
Display Accuracy ±
2%
Accuracy
+/-2 %
Barrel Size
2.83"
Power Meter Range
0-750 W
Equipment Type
Wattage Meter
Range
0 - 750
Size
4.50 in
Meter Movement
Dynamometer
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
• Only 3.12” (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional
• Din Rail Adapter available
Mounting Requirements
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
point setting and display scaling
(page C1)
Dimensions
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ACCURACY @25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
4.04”
3.59”
3.75
1.88
7-segment, red LED
0.56" (14.2mm)
3 or 4 position user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
±0.02% of reading ± 1 count
750 ± 2 count
±0.1% of reading ± 1 count
750 ± 2 count
±0.05% of reading ±1 count
2A ± 5 counts
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz-1KHz)
±0.5% of reading ± 35 counts (45Hz-1KHz)
±1% of reading ± 5 counts (45Hz-1KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
(±0.1% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
50dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min.
Dual slope integration
3 samples per second, nominal
3.75" x 1.88" x .51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1g)
.51
2.94
5A ± 5 counts
92 mm
1.75
more >>
2.26
A
7

Related parts for 10760