Watt Meter

10760

Manufacturer Part Number10760
DescriptionWatt Meter
ManufacturerSimpson
10760 datasheets
 

Specifications of 10760

Meter FunctionWattMeter Range0W To 750W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-750 WEquipment TypeWattage Meter
Range0 - 750Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Page 31
32
Page 32
33
Page 33
34
Page 34
35
Page 35
36
Page 36
37
Page 37
38
Page 38
39
Page 39
40
Page 40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Page 33/68

Download datasheet (7Mb)Embed
PrevNext
Ordering Information
DC Milliammeters,
Self-Shielding Movement
Approx.
Model/Size and Catalog Number
Impedance
(0hms) @
1-1/2"
2-1/2"
Range
60 Hz
Model 1212
Model 1227
0-1
43.0
06163
06175
0-3
2.0
<>
06180
0-5
2.0
(20)†
06164
06190
0-10
10.0
(2.2)†
06165
06200
0-15
6.6
(2.2)†
06166
06210
0-20
5.0
<>
06215
0-25
4.0
(6.0)†
06167
06220
0-50
2.0
(3.0)†
06168
06230
0-100
1.0
(1.5)†
06169
06240
0-150
.66 (1.0)†
06170
06250
0-200
.50 (.75)†
06171
06260
0-250
.40 (.60)†
06172
06270
0-300
.33 (.50)†
06173
06280
0-500
.20 (.30)†
06174
06290
0-750
.13
<>
<>
0-1000
.05
<>
06292
† Impedance of Model 1212 shown in (
)
<> Available on special order
DC Ammeters,
Self Shielding Movement
Approx.
Model/Size and Catalog Number
Impedance
(0hms) @
1-1/2"
2-1/2"
Range
Model 1212
Model 1227
60 Hz
.050
02431
02440
0-1
.033
<>
02450
0-1.5
0-2
.025
02432
02460
0-3
.0166
02433
02470
0-5
.010
02434
02480
0-10
.005
02435
02490
0-15
.0033*
02436†
02500
0-25
.0020*
02437†
02510
0-30
.0017
<>
02520
0-50
.001*
02438†
02530
0-100
10.0
<>
02540†
0-150
10.0
<>
02550†
0-200
10.0
<>
02552†
0-300
10.0
<>
02554†
0-500
10.0
<>
<>
15-0-15
.0033
<>
<>
30-0-30
.0017
<>
<>
50-0-50
.001
<>
<>
† 1-1/2" DC current meters are self-contained through 10 amps. 15 amps
and higher are supplied as 50mV meters to be used with external shunts.
2-1/2", 3-1/2" and 4-1/2" DC current meters are self-contained through 50
amps. Higher range DC current meters are 50mV meters to be used with
external shunts.
<> Available on special order.
*Model 1212 only - 10 ohms
Wattmeters/Dynamometer Type, Not
Model/Size and Catalog Number
Maximum
Range
Amps
Volts
0-10
.175
150
0-20
.400
150
0-75
1.0
150
0-150
2.0
150
0-300
150
4.0
0-600
300
4.0
0-750
150
10.0
0-1500
300
10.0
0-3000
20.0
300
* Compensated wattmeters: calibrated for either magnetic or non-magnetic
panels and for a frequency of 25-125Hz.
DC Millivoltmeters,
Approx.
Impedance
(Ohms) @
Range
3-1/2"
4-1/2"
60 Hz
Model 1327
Model 1329
0-50
06310
06470
50-0-50
06320
06480
<> Available on special order.
06330
06490
06340
06495
DC Voltmeters,
06350
06502
06360
06524
Approx.
Impedance
06370
06530
(Ohms) @
06380
06540
Range
60 Hz
06390
06550
0-5
06400
06560
06410
06570
0-8
06420
06580
0-10
06430
06590
0-15
06440
06600
0-25
06450
06610
0-30
06460
06620
ohms
0-50
per volt
0-100
0-150
0-200
0-250
0-300
0-300
3-1/2"
4-1/2"
Model 1327
Model 1329
0-500
ohms
02640
0-750
02820
per volt
02650
02830
0-1000
02660
02840
*External multipliers (Model 183) are furnished on 1-1/2" DC meters 500 volts or
02670
02850
higher; on 2-1/2" DC meters 750 volts or higher; and on 3-1/2" and 4-1/2" DC
02680
02860
meters 1000 volts or higher. All others have self-contained multipliers.
<> Available on special order.
02690
02870
02700
02880
02710
02890
Percent Motor Load Meters
02720
02900
02730
02910
02740†
02920†
02750†
02930†
Type
02760†
02940†
DC (Note 1)
02770†
02950†
AC (Note 2)
02780†
02960†
02790
<>
Note 1: DC load meters require an external shunt and potentiometer (not supplied). Use 8
02800
<>
to 10 , 2 watt wire-wound potentiometer. The appropriate shunt should be selected from
02810
<>
accessory section and ordered separately. To select the proper shunt, first obtain the full-
load current rating of your motor from the name plate, manufacturer's specifications of
N.E.C. listing. Multiply that rating by 1.25 and select and order the shunt with an amps rat-
ing as large or slightly larger than the calculated value. Installation and calibration instruc-
tions are included with the meter.
Note 2: AC load meters must be used with external donut transformers. Complete instruc-
tions for proper selection are included with each AC load meter. Advance assistance in
selecting the appropriate transformer and determining the correct primary/secondary turns
ratio can be obtained from a Simpson technical service representative or authorized service
center.
4-20mA Process Meters
Size
4-1/2"
3-1/2"
Model 1379
10930*
4-1/2"
10940*
Frequency Meters,
10960
10970
10975
10980
Range
10990
45-55 Hz
11000
55-65Hz
380-420 Hz
11010
45-55 Hz
55-65Hz
380-420 Hz
Self Shielding Movement
Model/Size and Catalog Number
2 - 1/2"
1- 1/2”"
3 - 1/2"
Model 1227
Model 1212
Model 1327
10.0
07005
07010
07020
20.0
<>
<>
07021
Self Shielding Movement
Model/Size and Catalog Number
2 - 1/2"
1- 1/2”"
3 - 1/2"
Model 1227
Model 1212
Model 1327
09540
09550
09720
<>
<>
09730
09541
09560
09740
09542
09570
09750
09543
09580
09760
1000
09544
09590
09770
09545
09600
09780
09546
09610
09790
09547
09620
09800
<>
09622
09810
<>
09623
09820
<>
09630
09830
09548
<>
<>
2000
09549*
09640
09840
<>
09650*
09850
<>
09660*
09860*
Model/Size and Catalog Number
3 -1/2"
4 -1/2"
Catalog #
Rating
Model #
Model #
30mV
1327
07028
1329
5 amps
1357
03171
1359
Scale
Model
Catalog No.
0-100%
1327
0-100%
1329
Self-Shielding Movement
Model/Size and Catalog Number
2-1/2"
3-1/2"
Voltage
Model 1287
Model 1387
Model 1389
120V
35100
35106
120V
35102
35108
120V
35104
35110
240V
35101
35107
240V
35103
35109
240V
35105
35111
B
5
4 - 1/2"
Model 1329
07030
07031
4 - 1/2"
Model 1329
09870
09880
09890
09900
09910
09920
09930
09940
09950
09960
09970
09980
<>
09990
10000
10010*
Catalog #
07029
03301
35025
35026
4-1/2"
35112
35114
35116
35113
35115
35117