Watt Meter

10760

Manufacturer Part Number10760
DescriptionWatt Meter
ManufacturerSimpson
10760 datasheets
 


Specifications of 10760

Meter FunctionWattMeter Range0W To 750W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-750 WEquipment TypeWattage Meter
Range0 - 750Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Page 5/68

Download datasheet (7Mb)Embed
PrevNext
• 3/64 DIN Indicator
• Minimum depth - requires less than 0.7”
(17mm) behind the panel
• Snaps right into panel - no mounting
hardware required
Mounting Requirements
The Mini indicators require a panel cutout of 2.71" (68.8mm) wide by
0.89" (22.6mm) high, and a panel area of 0.94" (24mm) high by 2.83"
(72mm) wide. The depth behind the panel, including terminals, is 0.7"
(17.8mm). The front bezel protrudes 0.16" (4mm) from the front of the
mounting surface. The unit will snap-mount into panels from 0.050" to
0.125" thick. A 12-pin connector with 6" wire leads is included with each
unit for quick installation.
Specifications
DISPLAY
Type
Height
Decimal point
Overrange indication
Backlighting
Polarity
POWER REQUIREMENTS
DC Power
Power supply current
Backlight supply current
ACCURACY @ 25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Warmup time
Temperature Coefficient
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel cutout
Weight
Case Material
Input Specifications
DC Voltage
Range Resolution
Input
Max Input
Impedance (Unfused)
200mV
100µV
>100m
50V
2V
1mV
10m
250V
20V
10mV
10m
250V
200V
100mV
10m
250V
more >>
7-segment LCD
0.5" (12.7mm)
3 or 4 position user-programmable
Most significant = "1" other digits blank
Optional negative image, red backlighting at
5, 10, 12, 24 or 48 DCV
Auto with "-" indication, "+" indication implied
±5V, +5V and +9V
Low Power Indication included with 9V units
2mA max
50mA typical. For 24 and 48DCV,
10mA typical
3 1 1 /2 d d igit: ±(0.1% of reading + 1 count)
4 1 1 /2 d d igit: ±(0.04% of reading + 1 count)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing @ 40°C
Less than 20 minutes
(All inputs)
± (0.02% of input ± 0.2 digit)/°C
60dB, 50/60Hz
(with 1K
unbalanced @ 60 Hz) 90dB min
Integrating
3 samples/second-typical
0.94" x 2.83"
0.43"
0.89" x 2.71" (22.6mm x 68.8mm)
1.0oz (28.3g)
94-VO, UL-rated ABS
DC Current
Range Resolution
Voltage
Max Input
Drop
(Unfused)
200µA
100µA
200mV
10mA
2mA
1µA
200mV
40mA
20mA
10µA
200mV
100mA
200mA
100µA
200mV
400mA
A
1