WM12-96AV63CX CARLO GAVAZZI, WM12-96AV63CX Datasheet

Analog Panel Meter

WM12-96AV63CX

Manufacturer Part Number
WM12-96AV63CX
Description
Analog Panel Meter
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of WM12-96AV63CX

Meter Function
3-Phase Power Indicator
Meter Range
400-660 VAC
Meter Size/dimensions
96 X 96 X 61.4 In
Accuracy
+/- 0.5%
Meter Shape
Square
Lead Free Status / RoHS Status
na
Product Description
3-phase multifunction power
indicator with built-in pro-
gramming key-pad. Particu-
larly recommended for dis-
playing the main electrical
variables.
Type Selection
Range codes
AV5: 380/660V
AV6: 120/208V
Phase current: 0.03A to 6A
Neutral current: 0.09 to 6A
Rated inputs
Accuracy (display, RS485)
Additional errors
Temperature drift
Input specifications
Specifications are subject to change without notice
Energy Management
Multifunction indicator
Type WM12-96
Current
Voltage
(@25°C ±5°C, R.H. ≤60%)
Current
Neutral current
Phase-phase voltage
Phase-neutral voltage
Active and Apparent power,
Power factor
Reactive power
Frequency
Humidity
VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
L-L
L-L
/5(6)AAC
/5(6)AAC
Housing for panel mounting,
(front) protection degree IP65
as standard, and optional
RS485 serial output.
System
3 :
3 (shunt)
4
with CT=1 and VT=1 AV5:
1150W-VA-var, FS:230VLN,
400VLL; AV6: 285W-VA-var,
FS:57VLN, 100VLL
0.25 to 6A: ±(0.5% FS +1DGT)
0.03A to 0.25A: ±7DGT
0.25 to 6A: ±(1.5% FS +1DGT)
0.09A to 0.25A: ±7DGT
±(1.5% FS +1 DGT)
±(0.5% FS + 1 DGT)
0.25 to 6A: ±(1% FS +1DGT);
0.03A to 0.25A: ±(1% FS
+5DGT)
0.25 to 6A: ±(2% FS +1DGT);
0.03A to 0.25A: ±(2% FS
+5DGT)
±0.1%Hz (48 to 62Hz)
≤0.3% FS, 60% to 90% RH
≤ 200ppm/°C
1-2-3-phase,
unbalanced load,
with or without
neutral
WM12-96 DS061107
How to order
Model
Range code
System
Power supply
Option
Sampling rate
Display refresh time
Display
Input impedance
Frequency
Measurements
Overload protection
• Accuracy ±0.5 F.S. (current/voltage)
• Multifunction indicator
• Display of instantaneous variables: 3x3 digit
• Variable system and phase measurements: W, W
• A
• TRMS meas. of distorted sine waves (voltages/currents)
• Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC
• Protection degree (front): IP65
• Front dimensions: 96x96mm
• Optional RS422/485 serial output
• Alarms (visual only) V
Power supply
A:
B:
C:
D:
3:
Type
Read-out for the instant. var.
Coupling type
Crest factor
380/660V
120/208V
Current
var, VA, VA
max
Continuous voltage/current
For 500ms: voltage/current
, W
24VAC
-15+10%, 50-60Hz
48VAC
-15+10%, 50-60Hz
115VAC
-15+10%, 50-60Hz
230VAC
-15+10%, 50-60Hz
18 to 60VDC
dmd max
L-L
L-L
(AV5)
(AV6)
dmd
, PF, V, A, An, Hz
indication
WM12-96 AV5 3 D
LN
, An
Options
X:
S:
1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
700ms
Current, voltage, power,
power factor, frequency
TRMS measurement of
distorted waves.
Direct
< 3, max 10A peak
1 MΩ ±5%
453 KΩ ±5%
≤ 0.02Ω
48 to 62 Hz
1.2 F.S.
2 Un/36A
LED, 14mm
3x3 DGT
None
RS485 output
dmd
XX
,
1

Related parts for WM12-96AV63CX

WM12-96AV63CX Summary of contents

Page 1

... L-L Current Frequency Overload protection Continuous voltage/current For 500ms: voltage/current WM12-96 DS061107 , PF An, Hz dmd indication , An LN WM12-96 AV5 3 D Options X: None S: RS485 output 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 14mm 3x3 DGT Current, voltage, power, power factor, frequency TRMS measurement of distorted waves ...

Page 2

... Note: the alarm is only visual, by means of LED on the front of the instrument. Independent alarm (VL∑, An) max: A, Wdmd 24VAC -15 +10%, 50-60Hz 18 to 60VDC AC: 4.5 VA DC: 4W 500VAC/DC between measuring inputs and 4000VAC, 500VDC between power supply and RS485 4000 VAC (for 1 min) EN50084-1 (class A) residential environment, WM12-96 DS061107 ...

Page 3

... VAR L2 VAR system VAR system W dmd Hz (system) (system) W dmd MAX AL.U PF system WM12-96 DS061107 ABS self-extinguishing V-0 Panel Front: IP65 (standard), NEMA4x, NEMA12 Connections: IP20 Approx. 400 g (pack. incl.) Figure C Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum: 3rd to 16th harmonic Additional error: < ...

Page 4

... Fig. 5 2-phase connection Specifications are subject to change without notice 3-phase active power 3-phase apparent power 3-phase power factor Neutral current Fig. 3 ARON connection RS485 serial connection Fig. 6 [1] [2] [3] 1-Last instrument 2-1...n Instrument 3-SIU-PC 4-wire connection WM12-96 DS061107 ...

Page 5

... To program the configuration parameters and the display of the variables Key to enter programming and confirm selections Keys to: - programme values; - select functions; - display measuring pages. 2. Display 1 LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 96mm 61.4mm 91mm WM12-96 DS061107 15.4mm 5 ...

Related keywords