H7AN-4DM 100/240AC Omron, H7AN-4DM 100/240AC Datasheet
H7AN-4DM 100/240AC
Specifications of H7AN-4DM 100/240AC
Related parts for H7AN-4DM 100/240AC
H7AN-4DM 100/240AC Summary of contents
Page 1
... Built-in DC power supply for input devices 10-year lithium battery memory backup available Panel-mounting hardware included Ordering Information Add the supply voltage to the part number when you order. For example, H7AN-4DM-AC100-240. PRESET COUNTERS Counting method UP or DOWN (selectable) Memory backup Not provided ...
Page 2
... LED count value display (0.3 in) high characters, and LED indicators for count up and reset Digits digits Memory backup H7AN-M models have a 3-volt lithium battery that provides 10 years of memory retention (68 F) OUTPUT MODES SUMMARY Preset counters have outputs; totalizing counters H7AN-T do not have outputs. Output ...
Page 3
... The selected mode is effective only after the counter is reset. MINIMUM PULSE WIDTHS To ensure proper operation, be certain the input pulse width is of sufficient duration for the counting speed. For H7AN, the ON/OFF ratio is 1:1. CHARACTERISTICS Ambient operating temperature ...
Page 4
... Count value Mode D (command inputs H L) Mode E (individual inputs H L) Mode F (phase difference inputs H7AN "A" shows the count input minimum pulse width. If the count input is less than minimum pulse width, a miscount occurs and the count total will be 1 count. Gate ...
Page 5
... DOWN and Reversible with H L Input Modes ( DOWN and Reversible with H L Input Modes ( One-shot output in single preset counters and 2nd output in double preset counters is adjustable from 0.1 to 1.0 second. 5 H7AN 1st preset 2nd preset count up count up Start ...
Page 6
... DOWN and Reversible with H L Input Modes ( DOWN and Reversible with H L Input Modes ( DOWN and Reversible with H L Input Modes ( DOWN and Reversible with H L Input Modes ( One-shot output in single preset counters and 2nd output in double preset counters is adjustable from 0.1 to 1.0 second. 6 H7AN ...
Page 7
... Panel cutouts 82 (3.23) 68 (2.68) 68 (2.68) 100 (3.94) max. Note: Panel cutout conforms to DIN 43700. Recommended panel thickness (0.039 to 0.197 in). 7 H7AN Two mounting brackets M3.5 terminal screws 67.7 (2.66) 115 (4.53) For side-by-side mounting of two units 68 (2.68) 142 (5.59) min. ...
Page 8
... Ground 8 3 Output terminal numbers, double preset counter Contact Out 2 4 and 5 Solid-state COM 8 Double preset H7AN counters RESET 30 VDC) Double preset counters Power supply for externally connected components when the counter is used in an environment with high levels of external noise. 8 H7AN ...
Page 9
... When applying a power-OFF reset, be sure to provide a reset signal time (power-OFF time) longer than 0.5 sec. POWER SUPPLY FOR EXTERNALLY CONNECTED EQUIPMENT H7AN counters have a built-in power supply for externally connected compo- nents such as sensors for count or reset input, or loads connected to the solid- state control output (12 VDC, 80 mA) ...
Page 10
... Count-up indicator Reset input indicator Pushbutton switch for manual reset Access screw One-shot time adjustment screw Contact output load Contact output load H7AN-4D, H7AN-4DM, H7AN-E4D, H7AN-E4DM H7AN-R6D, H7AN-R6DM 10 H7AN Solid-state output load Solid-state output load 7-segment LED display Count-up indicator Reset input indicator ...
Page 11
... DOWN display, manual reset function enable or disable, output level of the solid- state output when the count is up, and one-shot output/sustained output of the control output(s). H7AN-R8D, H7AN-R8DM H7AN-RT8, H7AN-RT8M Open the front cover to expose the access screw on the lower right side. 11 H7AN ...
Page 12
... DIP switches and slide switches mounted on the PC board located at the right side of the internal unit (when viewed from the front). H7AN-2D, H7AN-2DM SW4 SW2 H7AN-E2D, H7AN-E2DM SW4 1 2 SW1 SW2 SW1 Count input function selector Switch Input position ...
Page 13
... C and P or with quadrature (phase difference) input SW3-2 Count input 2 maximum counting speed selector switch 30 cps 5,000 cps in output modes 3,000 cps in output modes C and P or with quadrature (phase difference) input H7AN-E4D, H7AN-E4DM SW3 SW4 SW1 SW2 ...
Page 14
... 3,000 cps in output modes C and P or with quadrature (phase difference) input SW3-2 Count input 2 maximum counting speed selector switch 30 cps 5,000 cps in output modes 3,000 cps in output modes C and P or with quadrature (phase difference) input H7AN-WE4D, H7AN-WE4DM SW4 SW3 SW2 ...
Page 15
... A (command inputs (command inputs (individual inputs (quadrature inputs (command inputs (command inputs (individual inputs (quadrature inputs (command inputs (command inputs L H) H7AN-RW6D, H7AN-RW6DM SW3 SW4 SW1 SW2 SW1 Count input function selector Switch Input position mode 0 A (command inputs L H) ...
Page 16
... D (command inputs (command inputs (individual inputs (quadrature inputs (command inputs (command inputs L H) H7AN-T4, H7AN-T4M SW3 SW4 SW3-1 Count input 1 maximum counting speed selector switch 30 cps 5,000 cps (3,000 cps with quadrature input) on 4-digit totalizers 3,000 cps (1,000 cps with quadrature input and 8-digit totalizers ...
Page 17
... A (command inputs (individual inputs (quadrature inputs (command inputs (command inputs (individual inputs (quadrature inputs (command inputs (command inputs L H) H7AN-RT6, H7AN-RT6M, H7AN-RT8, H7AN-RT8M SW3 SW4 SW1 SW1 Count input function selector Switch Input position mode 0 A (command inputs (command inputs L H) ...
Page 18
... H7AN Installation MOUNTING The illustrations at right show how to mount the H7AN counter in a panel with the Y92H-5 mounting brackets supplied with each unit. Insert the counter through the panel. Loosen the screw on the bracket, then insert the bracket in the slot on the bottom of the counter. Tighten the screw until it makes a clicking sound ...
Page 19
... OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci Specifications subject to change without notice. 19 H7AN OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in the U.S.A. ...