CUB5VB00 Red Lion Controls, CUB5VB00 Datasheet
CUB5VB00
Specifications of CUB5VB00
Related parts for CUB5VB00
CUB5VB00 Summary of contents
Page 1
Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL CUB5V - MINIATURE ELECTRONIC 5-DIGIT DC VOLTMETER LISTED US LISTED R IND. CONT. EQ. 51EB GENERAL DESCRIPTION The CUB5 provides the user the ultimate in ...
Page 2
... ETER 1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits CUB5VR00: Reflective LCD with full viewing angle CUB5VB00: Transmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER: Input voltage range +28 VDC with short circuit and input polarity protection ...
Page 3
O P PTIONAL LUG ADDING OPTION CARDS The CUB5 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below. The plug-in cards, that are ...
Page 4
I NSTALLING The Plug-in cards are separately purchased option cards that perform specific functions. The cards plug into the main circuit board of the meter Range Jumpers Comms or Programming Card Locking Tab 4.0 W IRING THE WIRING OVERVIEW ...
Page 5
INPUT WIRING CAUTION: Power input common is NOT isolated from user and input commons. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or ...
Page 6
R EVIEWING THE BUTTON DISPLAY MODE OPERATION Index display through enabled values SEL Resets values (MIN/MAX) or outputs RST OPERATING MODE DISPLAY DESIGNATORS MAX - Maximum display capture value MIN - Minimum display capture value Pressing the button toggles ...
Page 7
MODULE 1-INP SEL rANGE dECPt OFSEt FILtr Input Display Display Filter Range Decimal Offset Setting Point Value CUB5V INPUT RANGE rAN6E RANGE SELECTION RESOLUTION 200u 200. 2.0000 V Select ...
Page 8
USER INPUT FUNCTION USrIN NO DISPLAY MODE DESCRIPTION NO No Function User Input disabled. See Programming Mode Access chart P-Loc Program Mode Lock-out (Module 3). Zero Input Zero the Input Display value causing ZErO (Edge triggered) Display Reading ...
Page 9
MODULE 3-dSP SEL dSP-t SEL rSt Display Front Panel Front Panel Update Time Display Reset Enable Select Enable DISPLAY UPDATE TIME dSP-t seconds 1 This parameter sets the display update ...
Page 10
MODULE 4-SPt SEL SPSEL Act-n SPt-n Setpoint Setpoint Setpoint Select Action Value The Setpoint Output Parameters are only active when an optional output module is installed in the meter. SETPOINT SELECT SPSEL NO SP-1 ...
Page 11
... Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P ...
Page 12
...