WM14-96AV53CS CARLO GAVAZZI, WM14-96AV53CS Datasheet

POWER ANALYZER

WM14-96AV53CS

Manufacturer Part Number
WM14-96AV53CS
Description
POWER ANALYZER
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of WM14-96AV53CS

Meter Function
Power Analyzer / Energy Management
Power Consumption
4W
Operating Temperature Range
0°C To +50°C
Rated inputs
Accuracy
Additional
Temperature drift
Product Description
3-phase power analyzer with
built-in programming key-
pad. Particularly recom-
mended for displaying the
main electrical variables.
Type Selection
Range codes
AV5:
AV6:
Phase current: 0.03A to 6A
Neutral current: 0.09 to 6A
Input specifications
Specifications
Power analyzers and
Power Analyzer
Type WM14-96
Current
Voltage
(@25°C ±5°C, R.H. 60%)
Current
Neutral current
Phase-phase voltage
Phase-neutral voltage
Active and Apparent power,
Reactive power
Active energy
Reactive energy
Frequency
Humidity
Optional RS422/485 serial port
Alarms (visual only) V
400/660V
VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
100/208V
VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
(display, RS485)
errors
are subject to change without notice
L-L
L-L
/5(6)AAC
/5(6)AAC
LN
, An
Housing for panel mounting,
(front) protection degree IP65
and optional RS485 serial
port.
System
3 :
3 (shunt)
4
with CT=1 and VT=1 AV5:
1150W-VA-var, FS:230VLN,
400VLL; AV6: 285W-VA-var,
FS:57VLN, 100VLL
0.25 to 6A: ±(0.5% FS +1DGT)
0.03A to 0.25A: ±7DGT
0.25 to 6A: ±(1.5% FS +1DGT)
0.09A to 0.25A: ±7DGT
±(1.5% FS +1 DGT)
±(0.5% FS + 1 DGT)
0.25 to 6A: ±(1% FS +1DGT);
0.03A to 0.25A: ±(1% FS
+5DGT)
0.25 to 6A: ±(2% FS +1DGT);
0.03A to 0.25A: ±(2% FS
+5DGT)
Class 2 (I start up: 30mA)
Class 3 (I start up: 30mA)
±0.1%Hz (48 to 62Hz)
0.3% FS, 60% to 90% RH
200ppm/°C
1-2-3-phase,
balanced/unbalanced
load,with or without
neutral
Energy Meters
WM14-96DS0904
How to order
Model
Range code
System
Power supply
Option
Sampling rate
Display
Display
Input impedance
Frequency
Measurements
Overload
Power supply
A:
B:
C:
D:
3:
Type
Read-out for instant. var.
Read-out for energies
Read-out for hour counter
Measuring method
Coupling type
Crest factor
400/660V
100/208V
Current
Class 2 (active energy)
Class 3
Accuracy
Display of instantaneous variables: 3x3 digit
Display of energies: 8+1 digit
System variables and phase
Energy
Hour counter (5+2 DGT)
TRMS meas. of distorted sine waves
Power analyzer
A
Power supply:
Protection degree (front): IP65
Front dimensions: 96x96mm
var, VA, VA
max
Continuos
For 500ms: voltage/current
, A
24VAC
-15+10%, 50-60Hz
48VAC
-15+10%, 50-60Hz
115VAC
-15+10%, 50-60Hz
230VAC
-15+10%, 50-60Hz
18 to 60VDC
refresh time
dmd max
measurements: kWh and kvarh
protection
(reactive energy)
L-L
L-L
±0.5 F.S. (current/voltage)
dmd
AV5)
AV6)
voltage/current
, W
, PF, V, A, An, A
24V, 48V, 115V, 230V 50-60Hz; 18 to 60VDC
dmd max
WM14-96 AV5 3 D
indication
dmd
measurements: W, W
Options
X:
S:
1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
700ms
Current, voltage, power,
power factor, frequency,
energy.
TRMS measurement
of distorted waves.
Direct
< 3; max 10A peak
1 M ±5%
453 K
48
1.2 F.S.
2 Un/36A
LED, 14mm
3x3 DGT
3+3+3 DGT (Max indication:
999 999 99.9)
1+3+3 DGT (Max. indication:
9 999 9.99)
, Hz
0.02
to 62 Hz
None
RS485 port
(voltages/currents)
±5%
XX
dmd
,
1

Related parts for WM14-96AV53CS

WM14-96AV53CS Summary of contents

Page 1

... WM14-96DS0904 ±0.5 F.S. (current/voltage) measurements PF An dmd dmd , W indication dmd max (voltages/currents) 24V, 48V, 115V, 230V 50-60Hz 60VDC WM14-96 AV5 3 D Options X: None S: RS485 port 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 14mm 3x3 DGT 3+3+3 DGT (Max indication: 999 999 99.9) 1+3+3 DGT (Max ...

Page 2

... A L1 dmd VLN Alarm and LN , An) 24VAC -15 +10%, 50-60Hz 18 to 60VDC AC: 4.5 VA DC: 4W measuring inputs and RS485. 4kVAC, 500VDC between power supply and RS485 4kVAC (for 1 min) EN50084-1 (class A) residential environment, commerce and light industry WM14-96DS0904 ...

Page 3

... W dmd MAX Wh Wh (LSD) varh varh (LSD) AL.U PF system 2) Example of kvarh visualization: This example is showing 3 553 944.9 kvarh WM14-96DS0904 ABS self-extinguishing V-0 Panel Front: IP65 (standard) Connections: IP20 Approx. 400 g (pack. incl.) Notes Decimal point blinking on the right of the display ...

Page 4

... Additional error: <0.5% FS Error =1 0.1A 0.25A 5A (Ib) (0.02Ib) (0.05Ib) 0.25A 0.5A 5A (Ib) (0.05Ib) (0.1Ib) Accuracy limits (Reactive energy) 5(6A) Start-up current: 30mA 3-phase active power 3-phase apparent power 3-phase power factor Neutral current are subject to change without notice 70...90% 10...30% 6A (Imax) 6A (Imax) L3 WM14-96DS0904 ...

Page 5

... WM14-96DS0904 Fig. 2 ARON and VT connection Fig. 5 1-phase connection Fig. 3 Fig ...

Page 6

... To program the configuration parameters and the display of the variables Key to enter programming and confirm selections; Keys to: - programme values; - select functions; - display measuring pages. 2. Display 1 LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 15.4mm 61.4mm Specifications are subject to change without notice 91mm WM14-96DS0904 ...

Related keywords