4501 DIGITRON, 4501 Datasheet

DPM, THERMOMETER TYPE K

4501

Manufacturer Part Number
4501
Description
DPM, THERMOMETER TYPE K
Manufacturer
DIGITRON
Datasheet

Specifications of 4501

Meter Function
Thermometer
Meter Range
-50°C To +700°C
Digit Height
11.2mm
Supply Voltage Range
216.2VAC To 253VAC
Operating Temperature Range
0°C To +45°C
External Depth
68.1mm
Accuracy %
0.5%

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
4501
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
4501-A0
Quantity:
7
Part Number:
4501-AO
Manufacturer:
TEMIC
Quantity:
81
Part Number:
4501-AO
Manufacturer:
ST
0
Part Number:
4501SS
Manufacturer:
GTM
Quantity:
20 000
SAFETY STATEMENT
The design of this instrument has been checked to EN61010 for Class 11
use.
This operating instruction contains information and warnings that must be
observed to keep the instrument in a safe condition. The instrument
should not be switched on if it is damaged and it should not be used
under wet conditions.
For the correct and safe use of this instrument it is essential that both
operating and service personnel follow generally accepted safety
procedures in addition to the safety precautions specified.
Whenever it is likely that a safety protection has been impaired the
instrument must be made inoperative and be secured against any
unintended operation. Qualified maintenance or repair personnel should
be informed.
Safety protection is likely to be impaired, if for example, the instrument
shows visible damage or fails to operate normally.
To clean the instrument, disconnect all power sources and then wipe the
surface lightly with a clean, soft cloth dampened with water.
The instrument should preferably be operated in a clean, dry environment
with an ambient temperature of between 0°C and +50°C.
Before removing the covers for installation, maintenance, or repair,
the mains supply must be isolated.
This instrument is specified for use in a Pollution Category 11
Environment which is normally non-conductive with temporary light
condensation. This instrument must not be used in more hostile,
dusty or wet conditions.
Do not use this instrument in a flammable or explosive
atmosphere.
INSTRUCTIONS
OPERATING
SERIES
WARNING
4000
WARRANTY
This instrument has been carefully assembled and tested, and is
warranted against faulty workmanship and materials for 12 months from
the date of purchase.
During the warranty period any defective instrument will be repaired or
replaced at the discretion of the manufacturer This warranty does not
cover damage or failure resulting from misuse or accident.
Modification, adjustment or any alteration with the internal arrangement of
the instrument shall absolve the manufacturer from any liability in respect
of the instrument.
Any instrument to be repaired should be forwarded to the manufacturer,
carriage paid and at the owner’s risk.
A brief description of the fault should be included.
SYMBOLS AND TERMS
POWER AND FREQUENCY REQUIREMENTS
This instrument operates from line voltages to Installation Category 11,
local level supplies distributed within the building.
WARNING
Supply Voltage:
Power Consumption:
Fuse Rating:
Email: digitronsales@digitron.co.uk Website: www.digitron.co.uk
Telephone: +44 (0)1803 407693 Fax: +44 (0)1803 407699
!
Woodland Road, Torquay, Devon TQ2 7AY England
A division of Sifam Instruments Limited
Where caution is required. Refers the user to the
operator manual for further information.
This symbol warns the user that high voltages are
present close to this symbol.
These statements identify conditions or practices that
could be dangerous or fatal to personnel.
Alternating current.
Equipment protected throughout by reinforced
insulation.
216-253V a.c. 50/60Hz
109-126V a.c. 50/60Hz
230V a.c. 25mA
115V a.c. 45mA
230V a.c. 50mA (T) UL/CSA
115V a.c. 50mA (T) UL/CSA
XG.0430 rev.3
Figure 1
SELECTING AND INSTALLING POWER SUPPLY
(MODELS 4501, 4504, 4801, 4804)
Remove the PCB from its housing, locate the supply voltage selector as
shown in Figure 1, then configure to the desired voltage.
The supply should be wired to the terminal connector and fitted to the
appropriate position as indicated on the back of unit.
The cable should be clamped into position using the clamping arms
provided. It is imperative that all covers are replaced before the power
supply is switched on.
This instrument has different mains wiring details to instruments in
the same series manufactured before January 1 1997. We
strongly recommend close attention to the instruction manual
supplied with this instrument.
The instrument is not fitted with a separate a.c. power supply
on/off switch and will have a.c. voltages present whenever it is
connected.
1 2 3 4
Hysteresis
Control
WARNING
NC.COM.NO
Alarm Contact
where fitted
L
N
L
N
115v
or
230v

Related parts for 4501

4501 Summary of contents

Page 1

... UL/CSA 115V a.c. 50mA (T) UL/CSA SELECTING AND INSTALLING POWER SUPPLY (MODELS 4501, 4504, 4801, 4804) Remove the PCB from its housing, locate the supply voltage selector as shown in Figure 1, then configure to the desired voltage. The supply should be wired to the terminal connector and fitted to the appropriate position as indicated on the back of unit ...

Page 2

... These should be connected as per the 2 wire sensors, but with terminal A+B and C+D linked Thermocouple THERMOCOUPLES (MODELS 4501, 4801) Thermocouples should, if possible, be wired directly into the terminal block taking care to observe the correct polarity. 4501/4801 +ve -ve If the thermocouple has to be extended, this should only be carried out by using extension or compensating cable of a type appropriate to the thermocouple being used ...

Related keywords