2053-3461-04 JEWELL / MODUTEC, 2053-3461-04 Datasheet - Page 4

Temperature Display Panel

2053-3461-04

Manufacturer Part Number
2053-3461-04
Description
Temperature Display Panel
Manufacturer
JEWELL / MODUTEC
Datasheet

Specifications of 2053-3461-04

No. Of Digits / Alpha
3.5
Meter Function
Frequency
Meter Range
40Hz To 199.9Hz
Digit Height
12.7mm
Operating Temperature Range
-20°C To +60°C
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
How to Order
2
a
b
c
d
e
f
Configuration
0 = 1/8 DIN
2 = TRMS (Inst)
Display
1 = Non Bklit
4 = Neg Grn Bklit 5 = Neg Red Bklit
6 = Pos Red Bklit
DPM Power
0 = loop power
2 = ±5VDC
4 = 115VAC
6 = 10 to 28VDC
8 = 12 VDC
Input
00 = 100mVDC (1999 counts)
01 = 200mVDC scaled 0 to 199.9
02 = 2VDC scaled 0 to 1.999
03 = 20VDC
04 = 200VDC
05 = 1V to 5 VDC scaled 0 to 100.0
06 = 10VDC scaled 0 to 10.00
07 = 500VDC
10 = 200uADC
11 = 2mADC
12 = 20mADC
13 = 200mADC
18 = 4 to 20mADC Sq Rt
19 = 4 to 20mADC scaled 0 to 100.0
21 = 200.0mVAC RMS
22 = 2.000VAC RMS
23 = 20.00VAC RMS
24 = 200.0VAC RMS
25 = 500VAC RMS
27 = 500VAC Avg
28 = 80.0 - 130.0VAC Avg
29 = 80 - 260VAC Avg
30 = 250VAC RMS
31 = 2.000mAAC RMS
32 = 20.00mAAC RMS
33 = 200.0mAAC RMS
34 = 2.000AAC RMS
36 = 5.00AAC
37 = 50.0AAC
38 = 0 - 5AAC
39 = 0 - 50AAC
60 = 40 to 440Hz
61 = 40.0 to 199.9Hz
70 = 100 Ohms Pt 1° Resolution
71 = 100 Ohms Pt .1° Resolution
80 = Type J Thermocouple
81 = Type K Thermocouple
82 = Type T Thermocouple
Backlit Power
00 = No Backlight 01 = 5VDC
02 = 12VDC
04 = 115VAC
06 = 10 to 28VDC 07 = 12 or 24VDC
Display
1 = 2000
4 = 600
7 = 200
0 3
a
b
3
5
1
- 3
2 = 1500
5 = 500
8 = 100
2
4
4
4
RMS
RMS
4
AVG
2
AVG
4 6 1
c
1 = UPM
3 = TRMS (Power)
3 = Pos Grn Bklit
1 = 9 VDC
3 = +5 volts
5 = 230VAC
7 = 12 or 24VDC (Iso)
9 = 24VDC
03 = 24VDC
05 = 230VAC
d
3
3 = 1000
6 = 300
-
0 4 2
e
3
f
2000 and 2100 Series Specifications (continued)
Type K thermocouple
Type T thermocouple
1
2
3
4
5
DC Inputs
AC Inputs
Frequency Inputs
Temperature Inputs
200mVDC & 2VDC ±(.1% +1 count) typical
20VDC & 200VDC
DC Current
Universal Selectable ±(.1% +2 counts)
Process
AC Voltage
5A AC Current
50A AC Current
40.0 to 199.9Hz
40 to 440Hz
Type J thermocouple
-10°F to +1200°F
(-23°C to +649°C)
-40°F to +1 500°F
(-40°C to +815°C)
-100°F to +600°F
(-73°C to +315°C)
100
-200°F to +600° F
(-129°C to +315°C)
100
-100.0°F to +199.9°F ±(.2% + 1 count) max
(-73°C to +98°C)
sales@jewellinstruments.com • www.jewellinstruments.com • 800 638-3771
850 Perimeter Road • Manchester, NH 03103 • USA
Change Order Number to “4” for 200 VDC Input
Backlit power must be the same as the selected DPM power.
Available on Non-Backlit meters only.
Rated for use with 5A or 50A external current transformer
supplied with DPM. See high current connection on inside page.
For 5A current transformer inputs only.
Pt. =.00385
Pt. =.00385
Accuracy
±(.2% +1 count) max.
±(.1% +1 count) typical
±(.2% +1 count) max.
±(.1% +1 count) typical
±(.2% +1 count) max.
Accuracy
±(.5% + 1 count)
±(.5% +1 count)
±(.5% +5 counts)
Accuracy
±.2Hz (40 to 70Hz)
±.5Hz (above 70Hz)
±1Hz
Accuracy
±(.1% +1 count) accuracy
±1.3°C (2.8°F)
conformity error
±(.1% +1 count) accuracy
±1.2°C (2.5°F)
conformity error
±(.1% +1 count) accuracy
±1.5°C (3.5°F)
conformity error
±(.2% + 1 count) max
1 Meg Ohm
200mV drop full scale
4 to 20mA, 10 Ohms
2V and up, 1Meg Ohm
Input Resistance
1 Meg Ohm
Current transformer
Current transformer
45 uV max per 100 Ohms
thermocouple lead resistance
45 uV max per 100 Ohms
thermocouple lead resistance
45 uV max per 100 Ohms
thermocouple lead resistance
1mA RTD current
1mA RTD current
Input Resistance
Distortion
Input Characteristic
200mV, 200K Ohms
.1 Hz for up to 20% third harmonic distortion
.1 Hz for up to 20% third harmonic distortion
100 Meg Ohms
Overload Protection
200V continuous
300V intermittent
350V continuous
500V intermittent
3 times f.s. current
4 to 20 mA, ±100mA
Voltage Inputs,
Overload Protection
350V continuous
500V intermittent
3 times f.s. current
3 times f.s. current
Overload Protection
200V continuous
200V continuous
200V continuous
±5V
±5V
200V continuous
300V intermittent