03580 Simpson, 03580 Datasheet - Page 57

Electromechanical Hour Meter

03580

Manufacturer Part Number
03580
Description
Electromechanical Hour Meter
Manufacturer
Simpson
Type
Elapsed Time Meterr
Datasheets

Specifications of 03580

Time Range
99999.9hr
Power Consumption
2.5W
Supply Voltage Max
120VAC
Time Range Max
99999.9h
Accuracy
Synchronous
Brand/series
Simpson Elapsed Time Meters
Dimensions
1.61"H×3.5"Dia.
Display Type
Digital
Function
Elapsed Time
Material, Casing
Plastic
Mounting Type
Panel
Number Of Digits
5.5
Primary Type
Electromechanical
Range, Measurement
0 to 99999.9 hrs.
Temperature, Operating
-4°F to +149°F
Voltage, Supply
120 VAC VAC
Indication
99,999.9 Hours
Equipment Type
Elapsed Time Meter
Range
0 - 120
Size
38.1 mm
Lead Free Status / RoHS Status
na
For Use With
AC or DC Powered Equipment
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• Wide Variety of Control, Alarm, and Limit
• Calibration Not Affected by Steel Panel
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Dimensions
Use
Mounting
Proof
4 - 1/2”-Model 3344AIXA & 3324AIXA
1
=
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
Movement:
Suspension:
Tracking:
Repeatability:
Shielding:
Response Time:
Overload (1 sec.):
Overload (Continuous):
Dial:
Case:
Voltage Drop:
Pointer:
Scale Length:
Net Weight:
Control Point(s)
Adjustments:
Switching:
Differential:
Auto/Manual Reset:
Contacts/Output Relay:
Frequency Response:
Power:
Operating Temperature:
Circuit-to-Ground
Voltage:
NOTE:
3 - 1/2”-Model 3343AIXA & 3323AIXA
AC: ±3% of full scale; DC: ±2% F.S.
Annular, self-shielding
Pivot and jewel
±3%
Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA
AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S.
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Sealed metal, plastic window
50mV
Black, knife-edge
4.05" (103.0mm)
17oz (0.48kg)
Single, high limit, 0-100% of arc; double, low limit 0-
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Within 1% of indication
“On,” “Off” difference is within 0.5% of F.S.
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
50-1000Hz
108-132 VAC, 50-400Hz
+41°F to 122°F (5°C to +50°C)
250V rms maximum
DC meters meet ANSI specification C-39.1
29
B

Related parts for 03580