CS1W-CN224 Omron, CS1W-CN224 Datasheet

no-image

CS1W-CN224

Manufacturer Part Number
CS1W-CN224
Description
"CABLE,CS1/C200H PRO27,2m"
Manufacturer
Omron
Datasheets

Specifications of CS1W-CN224

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rack PLCs
Rack PLCs
CS1 Series
Introduction
Lineup
CPU Units
Dimensions
I/O allocations
Current consumption
Unit Descriptions
Ordering Information
Power Supplies
Basic System Configuration
Duplex System Configuration
Programming
Basic I/O Units
Analog/Temperature Units
Position/Motion Units
Communication Units
Fieldbus Units
249
272
274
278
280
286
288
292
293
295
299
300
315
338
349
356
370
247

Related parts for CS1W-CN224

CS1W-CN224 Summary of contents

Page 1

Rack PLCs Rack PLCs CS1 Series Introduction Lineup CPU Units Power Supplies Basic System Configuration Duplex System Configuration Programming Dimensions I/O allocations Current consumption Unit Descriptions Basic I/O Units Analog/Temperature Units Position/Motion Units Communication Units Fieldbus Units Ordering Information 249 ...

Page 2

Programmable Controllers ...

Page 3

Rack PLC series CS1 The evolution of the SYSMAC CS1 is accelerating advances in the production site Ultimate Performance Further improvements to instruction execution efficiency, the core of overall PLC performance, enable the highest speeds in the industry. ...

Page 4

Seamless Networking The CS1 supports message communications across three network levels, from information networks down to component networks, allowing greater on- site information management. Remote monitoring of installations is also possible using Web functions via the Internet. 5 ...

Page 5

Use the improved SYSMAC CS1 PLCs to scale advanced systems to the optimum size. 1 Faster Instruction Execution and Faster Overall Performance In addition to further improvements to the The evolution of the instruction execution engine, which is the SYSMAC ...

Page 6

Improved Refresh Performance for Data Links, Remote I/O Communications, and Protocol Macros In the past, I/O refresh processing with the CPU Bus Unit only occurred during I/O refresh after instructions were executed. CPU Unit Immediate CPU Bus I/O refresh Unit ...

Page 7

Equipped with functions demanded by the production site to suit a variety of applications 2 Nested Interlocks Although strictly speaking the present The evolution of the interlock instructions do not allow nesting, SYSMAC CS1 is applications can be created to ...

Page 8

Convert Between Floating-point Decimal and Character Strings The new CS1 can convert floating-point decimal (real numbers) to character strings (ASCII) for display (operator interface). The data can be displayed on the character-string display element. ...

Page 9

... Temperature Controller unit number and address. What is the OMRON FB Library? The OMRON FB Library is a set of functional objects for ladder programming for OMRON CS/CJ-series PLCs. By incorporating the OMRON function blocks provided by OMRON into a ladder program, the program interface for different control devices is easily completed ...

Page 10

... Easy development of user applications for communications with the new CS1. SYSMAC Compolet: Accessing the CS1 with Visual Basic Use SYSMAC Compolet for communications with OMRON PLCs to greatly reduce development time of user applications for CS1 I/O memory read and write, forced set/reset, and FINS message communications using Visual Basic. ...

Page 11

... Note: For CPU Unit Ver. 2.0 or later. A Wide Range of Systems, from Small-scale to Large OMRON offers a full lineup of reliable PLCs including the "flagship" CS1 Series, and ranging from the small-scale CQM1H to the large-scale CV Series. The CS1 Series meets the needs not only of small- scale to large-scale systems, but of distributed systems as well ...

Page 12

Add a Redundant Optical Ring to Your Controller Link Communications A redundant network configuration will keep communications flowing over the duplicate ring-shaped path in the event of a broken optical fiber, preventing system malfunction. Head office, remote office, home, business ...

Page 13

... Component/PLC Note 1: FINS Abbreviation for Factory Interface Network Service. A command system for message services common to OMRON networks. FINS commands can be sent across network levels, including serial communications paths using a serial gateway. (Possible only with CS/CJ-series CPU Unit Ver. 2.0 or later.) Note 2: CompoWay/F CompoWay integrated communications protocol used for OMRON general-purpose serial communications ...

Page 14

... Console Host computer, etc. Host Link Serial Communications Board Peripheral bus CPU Unit (Programming Console bus) Programmable Terminal NT Link Protocol macros Microcomputer, Non-OMRON etc. PLCs, etc. No-protocol CPU Unit RS-232C Port Serial Communications Board TXD instruction TXD instruction or or RXD instruction ...

Page 15

Advanced management and resource inheritance providing powerful support for maintenance and operation 6 Remote Maintenance 1. Program or monitor a The evolution of the remote PLC via a modem SYSMAC CS1 is connection. accelerating advances 2. Program or monitor a ...

Page 16

Boost Program Security by Keeping Part of It Hidden (for CPU Unit Ver. 2.0 or Later) You can prevent access to special tasks by requiring the user to have a password to read them. Task 1 Use a password to ...

Page 17

The CS1 Duplex System Boots the Reliability of Facilities and Equipment 7 Duplex-CPU System The evolution of the SYSMAC CS1 is accelerating advances in the production site. Hot Standby System Adopted for CPU Unit Duplexing The system can also be ...

Page 18

... PLCs with Controller Link Even if one Unit fails, the other Unit will back it up and continue communications. Even if a line breaks, a loopback will be used to maintain the network. Either the CS1W-CLK12-V1 or CS1W-CLK52-V1 is required for a Duplex Controller Link network. Line backed up with loopback Break Unit failed ...

Page 19

Machine performance improved with high-speed, high precision, flexible motion control Position Control Units Two Types of Outputs and Control Axes Select from 1-axis, 2-axis, and 4-axis models with either open-collector output or line-driver output ...

Page 20

... Smart Process Control OMRON PLC-based Process Control brings Major Innovations to Process Automation 9 The evolution of the SYSMAC CS1 is accelerating advances in the production site. 266 Function block programming Sequence programming using either step ladders or sequence tables A direct link to HMI products Provides an exceptionally open environment with PLC-based process control to advance standardization and IT integration of the process control system ...

Page 21

Diversified Loop Control is even easier to use. Programming becomes even easier with function-block programming. Packed with complete DCS functionality, the LCBs/LCUs are programmed with function blocks designed specifically for process control. Similar to preparing a flow sheet, function blocks ...

Page 22

... SYSMAC CS1 is accelerating advances in the production site. 268 Configurator Ethernet Programmable Terminal NT631 DeviceNet Interface Unit NT-DRT21 SYSMAC CS-series DeviceNet Unit CS1W-DRM21-V1 Transistor Remote I/O Smart Slave Terminals with 3-tier Terminal Block Environment-resistive DRT2-ID16(-1)/ Terminals OD16(-1)/ DRT2-HD16C (-1) MD16TA(-1) DRT2-ID08C/OD08C (-1) Transistor Connector ...

Page 23

Advantages in Development and Design Hardware Advantages Many compatible components for more options and easier system construction. No restrictions on Master, enabling equipment modularization at the Slaves. Software Advantages Simple software standardization with profile specified for each component. Open network ...

Page 24

Greater Compatibility with PLCs Multilingual Globalization for Greater Machine Flexibility 11 Ladder Monitor Function Save the NS-EXT01 Ladder Monitor The evolution of the system program on a Memory Card (the SYSMAC CS1 is NS-EXT01 is sold separately) and install the ...

Page 25

... RAKURAKU CHUUGOKUGO and RAKURAKU KANKOKUGO (Chinese and Korean input systems) to convert Japanese to Chinese and Korean. For more information on this software, refer to the following site or send email to the following address. URL: http://www.omronsoft.co.jp/SP/ E-mail: rakuraku@omuronsoft.co.jp NS5-V1 NS8-V1 NS10-V1 NS12-V1 5-inch Model ...

Page 26

... CS1W-BC@@@ ( slots) CS1D-BC @@@ (5 slot duplex CPU, 8 slot single CPU) Note: Expansion is not possible for 2-slot Backplanes. These Backplanes are for CS1 Units only. Use a CS1W-BC@@3 Backplane for C200H Units. CPU Units Power Supply Units CS1G-CPU@@H C200HW-PA@@@/-PD@@@ CS1D-CPU@@H/P/S CS1D-PA@@@/-PD@@@ Memory Card ...

Page 27

... Relay Output Unit: CS1W-OA201 CS1W-OA211 CS1W-OC201 High-speed Input Safety Relay Unit Unit 16 pts CS1W-SF200 CS1W-IDP01 Analog Output Unit Analog I/O Unit CS1W-DA041/ CS1W-MAD44 08V/08C High-speed Counter SSI input unit Unit CS1W-CTS21 CS1W-CT021/041 Position Control CAN(open) Unit PROFIBUS-DP Units* C200HW- Master Unit ...

Page 28

CS1H/G-CPU@@H CS1-series Inner Board Compartment An Inner Board can be mounted here. Peripheral Port The peripheral port connects Programming Devices, such as a Programming Console or host computer. RS-232C Port The RS-232C port connects Peripheral Devices other than Programming Consoles, ...

Page 29

Specifications CPU Units Model I/O bits CS1H-CPU67H 5,120 bits CS1D-CPU67H ( Expansion Racks) CS1D-CPU67S CS1D-CPU67P CS1H-CPU66H CS1H-CPU65H CS1D-CPU65H CS1D-CPU65S CS1D-CPU65P CS1H-CPU64H CS1H-CPU63H CS1G-CPU45H 5,120 bits ( Expansion Racks) CS1G-CPU44H 1,280 bits CS1D-CPU44S ( Expansion ...

Page 30

Item Specification CIO (Core I/O) Ar- I/O Terminal Area 512 (32 words): CIO 310000 to CIO 313115 (words CIO 3100 to CIO 3131) ea, contd. I/O Terminal bits are allocated to I/O Terminal Units (but not to Slave Racks) connected ...

Page 31

... PA204R and C200HW-PA209R Power Supply Units. Battery life 5 years (Depending on the ambient operating temperature and communications conditions, 1.1 years min. Battery Set: CS1W-BAT01) Note: Use a replacement battery that is no more than 2 years old from the date of manufacture. Self-diagnostics CPU errors (watchdog timer), I/O verification errors, I/O bus errors, memory errors, and battery errors. ...

Page 32

Specifications - Power Supply Units Item Specifications Power Supply Unit C200HW-PA204 Supply voltage 100 to 120 200 to 240 V AC, 50/60 Hz Operating voltage range 85 to 132 170 to 264 V AC ...

Page 33

Specifications - Duplex Power Supply Units Item Specifications Power Supply Unit CS1D-PA207R Supply voltage 100 to 120 200 to 240 V AC, 50/60 Hz Operating voltage range 85 to 132 170 to 264 V ...

Page 34

... One of each Unit required for every CPU Rack. Refer to the following table for model number. Install as required. Refer to the following table for model number. These Backplanes are for CS1 Units only. Use CS1W-BC@@3 Backplanes if C200H Units are to be installed. Programmable Controllers ...

Page 35

... HMC-EF372 Memory Cards HMC-EF672 HMC-AP001 Serial Communications Boards CS1W-SCB21-V1 CS1W-SCB41-V1 Programming Consoles CQM1-PRO01-E C200H-PRO27-E Programming Console Connection CS1W-CN114 Cables CS1W-CN224 CS1W-CN624 CX-One CX-ONE-AL##C-E Programming Device Connecting CS1W-CN118 Cables (for peripheral port) CS1W-CN226 CS1W-CN626 XW2Z-200S-CV XW2Z-500S-CV Programming Device Connecting XW2Z-200S-V Cable (for RS-232C port) ...

Page 36

... CS1 Expansion Racks within 12 m. Connects CS1 Expansion I/O Backplanes to CPU Backplanes or other CS1 Expansion I/O Backplanes. When using a CS1W-CN313 or CS1W-CN713 I/O Connecting Cable with a CS1@-CPU@@H CPU Unit, use only Cables produced on or after September 20, 2001 (production number 2091). Cables with no production number, a 6-digit production number, or produced before September 20, 2001, cannot be used ...

Page 37

Expansion Rack Patterns The following diagrams show the 5 possible patterns of Expansion Racks. CPU Rack with CS1 Expansion Racks CPU Rack CS1 I/O Connecting Cable CS1 Expansion Rack CS1 I Connecting Cable CS1 Expansion Rack CS1 I/O ...

Page 38

CPU Rack with C200H Expansion I/O Racks CS1 to C200H Expansion C200H I/O Connecting I/O Rack Cable C200H I/O C200H Expansion 12 m Connecting I/O Rack Cable C200H I/O Connecting C200H Expansion Cable I/O Rack 284 CPU Rack 3 Racks ...

Page 39

CPU Rack with CS1 Expansion Rack and CS1 Long-Distance Expansion Racks CPU Rack CS1 I/O Connecting Cables 0.7 m I/O Control Unit CS1 Expansion Rack Long-distance Connecting Cables I/O Interface Unit CS1 Expansion Rack Long-distance Connecting Cable I/O Interface Unit ...

Page 40

System Configuration (Duplex Systems) Duplex-CPU System Duplex CPU Backplane CS1D-BC052 (See note Units can be mounted. CS1-series Basic I/O Units CS1-series Special I/O Units CS1-series CPU Bus Units Note: C200H Units cannot be mounted. Single-CPU System Duplex ...

Page 41

... CV500-CN322 CV500-CN522 CV500-CN132 CV500-CN232 CV500-CN332 CV500-CN432 CV500-CN532 CS1-C200H I/O CS1W-CN311 Connecting Cables CS1W-CN711 CS1W-CN221 CS1W-CN321 CS1W-CN521 CS1W-CN131 CS1W-CN131-B2 C200H I/O Connecting C200H-CN311 Cables C200H-CN711 C200H-CN221 C200H-CN521 C200H-CN131 CS1-series I/O Control Unit CS1D CPU Rack Long-distance Connecting Cable I/O Interface Unit CS1D Expansion Rack ...

Page 42

... XW2Z-500S-CV (See note.) Note: Refer to the next page for details of cables for connecting to computers. Choose the appropriate cable for the communications mode. 288 Serial Communications Units Serial Communications Board Hardware USB-Serial IBM PC/AT or Conversion Cable compatible CS1W-CIP31 Peripheral port Software CX-One Programmable Controllers ...

Page 43

... Connecting Cable CS1W-CN226 CS1W-CN626 XW2Z-@00S-@(@) CS1W-CN118 RS-232C Cable (See previous page.) CS1W-CN114 CQM1-CIF02 Connecting Cable RS-232C connector (25 pins) CS1W-CN224 CS1W-CN624 Hardware USB-Serial IBM PC/AT or compatible Conversion Cable CS1W-CIF31 USB-Serial IBM PC/AT or compatible Conversion Cable CS1W-CIF31 USB-Serial IBM PC/AT or compatible Conversion Cable ...

Page 44

... Cable length The following cables can be used for an RS-232C connection from the --- computer to the peripheral port. Mode Peripheral bus or Host Link Host Link CS1W-CN224: 2.0 m CS1W-CN624: 6.0 m Connecting to the RS-232C Port Peripheral port Cable length 2.0 m 6.0 m RS-232C Port Connecting Cables Mode ...

Page 45

... SYSMAC WAY RS-232C Port Connecting Cables Computer Serial Communications Node IBM PC/AT or compatible Tool bus or SYSMAC WAY CS1W-CIF31 SYSMAC WAY Connection in Tool Bus Mode is not possible. The connector does not have ESD measures. Applicable Software CX-Programmer, CX-Simulator, CX-Protocol, CX-Motion, CX-Positio- ner, CS-Process, DeviceNet Configurator, PLC Reporter 32, CX-Desi- gner, and NT Support Software for Windows (NTST) (See note ...

Page 46

... Model A W CS1W-BC022/023 (2 slots) 172.3 198.5 CS1W-BC032/033 (3 slots) 246 260 CS1W-BC052/053 (5 slots) 316 330 CS1W-BC082/083 (8 slots) 421 435 CS1W-BC102/103 (10 slots) 491 505 CS1D-BC052/082S (Duplex System) CS1W-BI032/033 (3 slots) 246 260 CS1W-BI052/053 (5 slots) 316 330 CS1W-BI082/083 (8 slots) 421 435 CS1W-BI102/103 (10 slots) 491 505 ...

Page 47

I/O Allocations I/O Allocations In CS1 PLCs, part of the I/O memory is allocated to each Unit. Units are divided into the following 3 groups for allocations. • Basic I/O Units • Special I/O Units • CS1 CPU Bus Units ...

Page 48

Allocations to CS1 Expansion and C200H Expansion I/O Racks I/O allocations to Basic I/O Units continue from the CPU Rack to the Expansion Racks. Words are allocated from left to right and each Unit is allocated as many words ...

Page 49

... CS1W-ID291 Output Units C200H-OC221 Special I/O Unit C200H-NC213 CPU Bus Unit CS1W-CLK21 Service Power Supply Unit (24 V DC) Total current/power consumption 13.15+3.9+7.2 = 24. Allocations to CS1 CPU Bus Units Each CS1 CPU Bus Unit is allocated 25 words in the CS1 CPU Bus Unit Area (CIO 1500 to CIO 1899). ...

Page 50

... AC Input Units 0.82 (See note.) Interrupt Input 0.82 (See note.) Unit High-speed Input Unit 0.82 (See note.) Safety Relay Unit CS1W-SF200 0.82 (See note.) C200H Output Relay Output 0.78 (See note.) Units Units 0.78 (See note.) 0.78 (See note.) ...

Page 51

... Input Unit (Ni508.4 ) 0.33 Isolated Two-wire 0.33 Transmission Device 0.33 Input Unit 0.33 Isolated DC Input Unit 0.33 0.45 0.45 Isolated Pulse Input Unit CS1W-PPS01 0.45 Isolated Control 0.45 Output Unit 0.33 Power Transducer 0.33 Input Unit 0.33 100-mV DC Input Unit 0.30 Motion Control Units 0 ...

Page 52

... Analog Input Unit C200H-AD003 cial I/O Analog Output C200H-DA003 Units Units C200H-DA004 Analog I/O Unit C200H-MAD01 ID Sensor Units C200H-IDS01-V1 C200H-IDS21 CS1 Special Analog Input Unit CS1W-AD0@1-V1 I/O Units CS1W-AD161 Analog Output CS1W-DA041 Units CS1W-DA08V CS1W-DA08C Analog I/O Unit CS1W-MAD44 Isolated CS1W-PTS01 Thermocouple ...

Page 53

... Inner Board CS1W-SCB@1-V1 CS1 CPU Bus Unit CS1W-SCU21-V1 --- NT-AL001 --- CS1W-GPI01 CS1 CPU Bus Unit CS1W-ETN21, CS1D-ETN21D 357 CS1 CPU Bus Unit CS1W-CLK@@-V1 Personal computer ISA board 3F8F7-CLK@@-V1 CS1 CPU Bus Unit CS1W-PRM21 C200H Special I/O Unit C200HW-PRT21 CS1 CPU Bus Unit ...

Page 54

... CS1W-OD29@ CS1W-OD26@ 96 points 64 points I/O Units I/O Units CS1W-MD29@ CS1W-MD26@ 48/48 points 32/32 points Input Unit Relay Output Unit C200H-ID@@@ CS1W-OC201 32/64 points 8 independent points Output Units Relay Output Unit C200H-OD@@@@ CS1W-OC211 32/64 points 16 points Inputs Connections 16 pts Removable terminal block ...

Page 55

... Model C200H-IM211 C200H-IM212 Model CS1W-OC201 CS1W-OC211 C200H-OC221 C200H-OC222 C200H-OC222N C200H-OC225 C200H-OC226N C200H-OC223 C200H-OC224 C200H-OC224N Model CS1W-OD211 CS1W-OD212 CS1W-OD231 CS1W-OD232 CS1W-OD261 CS1W-OD262 CS1W-OD291 CS1W-OD292 C200H-OD411 C200H-OD213 C200H-OD214 C200H-OD216 C200H-OD211 C200H-OD212 C200H-OD217 C200H-OD21A C200H-OD212 C200H-OD218 C200H-OD21B C200H-OD219 C200H-OD215 Model C200H-OD501 Model CS1W-OA201 CS1W-OA211 ...

Page 56

... Max. switching capacity 16 pts Terminal arrangement Polarity of the input power supply can connected in either direction. Model Remarks CS1W-MD261 --- CS1W-MD262 --- CS1W-MD291 --- CS1W-MD292 --- C200H-MD215 Pulse-catch inputs, 128-pt dynamic outputs possible C200H-MD115 Model Remarks CS1W-MD561 --- C200H-MD501 Pulse-catch, 128-pt dynamic outputs possible Model CS1W-IDP01 Programmable Controllers ...

Page 57

... CS1W-ID231 Circuit configuration 3.9 k 1000 pF 560 Input indicator 3.9 k 1000 pF 560 CS1W-ID261 Circuit configuration 3.9 k 1000 pF 560 Input indicator 3.9 k 1000 pF 560 Basic I/O Units Terminal arrangement I/O word "m + 1" Terminal arrangement I/O word "m+1" Indicator switching circuit I/O word "m" ...

Page 58

... CN1 circuits 1000 pF Input indicator 4 CN2 circuits 1000 pF CS1W-IA111 Circuit configuration IN0 to IN7 2.2 k COM0 Input indicator IN8 to 2.2 k IN15 COM1 CS1W-IA211 Circuit configuration IN0 to IN7 COM0 Input indicator IN8 to IN15 COM1 304 Terminal arrangement 560 Indicator switch circuit 560 Terminal arrangement ...

Page 59

... CS1W-OC201 Circuit configuration Output indicator CS1W-OC211 Circuit configuration Output indicator CS1W-OD211 Circuit configuration Output indicator Basic I/O Units Terminal arrangement See note 2. OUT OUT 250 V AC DC, 0.1 A 120 V DC max. Note: There are no restrictions in the polarity when connecting a DC power supply. ...

Page 60

... CS1W-OD212 Circuit configuration Output indicator ERR indicator CS1W-OD231 Circuit configuration Output indicator 306 Terminal arrangement Terminal arrangement I/O word "m + 1" I/O word "m" Programmable Controllers ...

Page 61

... CS1W-OD232 Circuit configuration Output Indicator ERR indicator CS1W-OD261 Circuit configuration I/O indicator 3.9 k 1000 pF 560 CS1W-OD262 Circuit configuration Output indicator ERR indicator Basic I/O Units Terminal arrangement Output Indicator ERR indicator Terminal arrangement I/O word "m+1" (Outputs (Inputs) Terminal arrangement CN1 I/O word " ...

Page 62

... CS1W-OD291 Circuit configuration Fuse Indicator switch circuit Output indicator Blown fuse detection ERR indicator circuit Fuse CS1W-OD292 Circuit configuration Fuse Indicator switch circuit Output indicator Blown fuse detection ERR indicator circuit Fuse 308 Terminal arrangement 10 CN1 circuits 10 ...

Page 63

... CS1W-OA201 Circuit configuration Output indicator ERR indicator CS1W-OA211 Circuit configuration Output indicator CS1W-MD261 Circuit configuration I/O indicator 3.9 k 1000 pF 560 Basic I/O Units Terminal arrangement IN0 to IN7 Fuse COM Blown fuse detection circuit Terminal arrangement IN0 to IN7 COM0 Fuse IN8 0.5 A ...

Page 64

... CS1W-MD262 Circuit configuration I/O indicator 3.9 k 1000 pF 560 ERR indicator CS1W-MD291 Circuit configuration Fuse Indicator switch circuit Output indicator Blown fuse detection ERR indicator circuit 4.7 k 1000 pF 560 310 Terminal arrangement I/O word "m+1" (Outputs (Inputs) Terminal arrangement 10 CN1 (Output CN2 (Input) I/O word " ...

Page 65

... CS1W-MD292 Circuit configuration Fuse Indicator switch circuit Output indicator Blown fuse detection ERR indicator circuit 4.7 k 1000 pF 560 CS1W-MD561 Circuit configuration 4.7 k 100 4.7 k 1.1 k 2.4 k 1000 pF Basic I/O Units Terminal arrangement x 3 CN1 (Output CN2 (Input) Terminal arrangement CN1 +V I/O word "m+1" ...

Page 66

... CS1W-IDP01 Circuit configuration 3.3 k 470 IN00 to IN07 1000 pF Input indicator 3.3 k 470 IN08 to IN15 1000 pF 312 Terminal arrangement Polarity of the input power supply can be connected in either direction. *2 Terminal numbers and are used in this manual, but they are not printed the Unit. ...

Page 67

... I/O Interrupt Task (CS1G/CS1H Only). The Interrupt Input Unit operates as a regular Input Unit in the CS1D PLCs. • Mount the Interrupt Input Unit in the CPU Rack. • CS1W-INT01 or 4 C200HS-INT01 Interrupt Input Units can be mounted. System Configuration CPU Unit Circuit Configuration (CS1W-INT01) 3 ...

Page 68

... Specifications Classifications Input voltage CS1W Basic I/O Unit C200H Basic I/O Unit Note: The interrupt function can be used with the CPU backplane (except CS1D) only. 314 Inputs Input pulse width Connections 16 pts ON: 0.1 ms min. Removable terminal OFF: 0.5 ms min. block 8 pts ON: 0 ...

Page 69

C200H-TM001 Analog Timer Unit Easy On-site timer Adjustments • Provides four timers easily adjusted on-site via front-panel adjustments or external variable resis- tors: No Programming Device required. Using timer pause inputs enables Usage as accumulative timer. System Configuration Analog Timer ...

Page 70

... CS1W-SF200 Safety Relay Unit Reduced Wiring and Space for Safety Circuits • This Safety Relay Unit mounts as an I/O Unit and provides both safety relays and inputs for monitor- ing. • Safety relays and monitor inputs in 1 Unit to reduce wiring and space. ...

Page 71

... CS1W-AD081-V1 8 inputs CS1W-AD161 16 inputs CS1W-PTW01 4 inputs CS1W-PDC11 4 inputs CS1W-PDC55 8 inputs CS1W-PTR01 CS1W-PTR02 C200H-AD003 Analog Output CS1W-DA041 4 outputs Units CS1W-DA08V 8 outputs CS1W-DA08C C200H-DA003 8 outputs C200H-DA004 Analog I/O Unit CS1W-MAD44 4 inputs and 4 outputs C200H-MAD01 2 inputs and 2 outputs Temperature CS1W-PTS11 4 inputs Sensor Input Units ...

Page 72

... CS1W-AD@@1-V1, C200H-AD003 Analog Input Units Convert Analog Signals to Binary Data • Wire burnout detection • Peak-hold function • Moving average filter function • Offset gain setting Note: Analog Input Terminals are also available as remote I/O terminals for DeviceNet, PROFIBUS-DP or CompoBus/S. ...

Page 73

... Input Input 8+ 28 Current mode Input C200HW-AD003 CS1W-AD161 C200 Special I/O Units CS1 Special I/O Units pts 16 pts --- Yes 8 settings 16 settings (one for each point) (one for each point) 1/4000 1/8000 1 ms/pt. max 0.25 ms/pt Voltage: 0.2% Current: 0. point MIL connectors ...

Page 74

... CS1W-DA0@@, C200H-DA00@ Analog Output Units Convert Binary Data to Analog Signals • Output limit • Upper/Lower limit alarms • Offset gain adjustment Note: The functions provided depend in the model used. Analog Output Terminals are also available as remote I/O terminals for DeviceNet, PROFIBUS-DP or CompoBus/S ...

Page 75

... Voltage: 0.3%FS Current: 0.5%FS Connections Terminal block Features Output hold function --- Note: Process I/O Units with individually isolated channels are also available for analog I/O. Refer to page 326. Analog Output Units CS1W-DA08V CS1W-DA08C C200H-DA003 C200H Special I/O Units pts 8 pts 8 pts Yes ...

Page 76

... – Resolution Conversion speed Overall Inputs accuracy Outputs Connections Features Mean function Peak hold Wire burnout detection Output hold Ratio conversion 322 Terminal Arrangement (CS1W-MAD44) Output 2 (+) B1 Output 2 (–) B2 Output 4 (+) B3 Output 4 (–) B4 N.C. B5 Input 2 (+) B6 Input 2 (– Input 4 (+) B9 Input 4 (–) ...

Page 77

... CS1W-LC001, CS1W-LCB01/05, CS1D-CPU@@P Loop Control Unit Integrate Process Control and Monitoring functions with PLC sequence control. With easy-to-use DCS-style function block configuration, complex control systems can be set up in minutes. • The control system can be scaled to match the con- trolled system, from a few loops that replace a Con- troller to hundreds of loops that perform large-scale process control ...

Page 78

... Heat exchanger Steam Cold water Drain Specification Loop Control Board CS-series Inner Board CS1W-LCB01 Standard CS1W-LCB05 Ad- Inner Board vanced Inner Board CS1G/H-CPU@@F CS1G/H-CPU@@H CPU Unit’s Inner Board slot 1 Board max. per CPU Unit User Link Table function: A function block’s ITEM data can be allocated to specified words in a CPU Unit data area (CIO, WR, HR, DM bank 0) ...

Page 79

... PID control with differential gap, override control, program control, time-proportional control, etc alarms (upper upper-limit, upper limit, lower limit, lower lower-limit) and 1 deviation alarm per PID block High/low alarm blocks, deviation alarm blocks CS1W-LC001 Settable cycles: 0.1, 0.2, 0. (default Can be set for each function block ...

Page 80

... Choose from a total of 13 models, including 11 isolated-type models, to handle essentially all normal data collection and process control applications. High-speed (10 ms) and high-resolution (1/64,000) models are available for use in a wide range of applications, from data logging to high-speed temperature control. Terminal Arrangement CS1W-PTS01-V1 CS1W-PTS01-V1 Isolated-type Thermocouple Input Unit N.C. N.C. N.C. 1+ ...

Page 81

... CS1W-PTS11 N.C. B1 N. N.C. B8 N.C. B9 N.C. B10 CS1W-PTS51 No. 2 thermocouple input Cold junction sensor No. 4 thermocouple input External alarm outputs Process I/O Units A1 N.C. No CJ1+ thermocouple input A3 CJ1 CJ2+ No thermocouple A9 CJ2 input (*1) A10 N.C. A11 N. ALM2 ALM1 ...

Page 82

... B11 A12 CJ2- N.C. B12 No. 8 thermocouple input No. 7 thermocouple input No. 6 thermocouple input No. 5 thermocouple input CS1W-PTS02 Isolated-type Resistance Thermometer Unit Cold junction sensor Cold junction sensor Resistance thermometer No. 1 input Resistance thermometer No. 3 input Resistance thermometer No. 4 input Programmable Controllers ...

Page 83

... CS1W-PTS03 CS1W-PTS03 Isolated-type Resistance Thermometer Unit Resistance thermometer Input No. 2 CS1W-PTS12 No. 2 Platinum- resistance Thermometer input CS1W-PTS52 No. 2 Platinum-resistance Thermometer input No. 4 Platinum-resistance Thermometer input External alarm outputs Process I/O Units A1 N. N.C. N. N.C. B9 A10 4B N.C. B10 A11 ...

Page 84

... CS1W-PTS56 No. 1 Platinum-resistance Thermometer input No. 3 Platinum-resistance Thermometer input No. 5 Platinum-resistance Thermometer input No. 7 Platinum-resistance Thermometer input CS1W-PTW01 CS1W-PTW01 Isolated-type 2-Wire Transmitter Input Unit CS1W-PDC01 Voltage input Voltage output device Voltage output device Voltage output device Voltage output device 330 1A B1 ...

Page 85

... N.C. Current inputs + + Current output Voltage device - output device - + + Current output Voltage device - output device - + + Current output Voltage device - output device - + + Current output Voltage device - output device - CS1W-PRT01 Power Transducer Input Unit CS1W-PDC11 N.C. B9 A10 N.C. B10 A11 N.C. ...

Page 86

... CS1W-PTR02 Voltage output device Voltage output device Voltage output device Voltage output device 332 CS1W-PRT02 Analog Input Unit Voltage output device Voltage output device Voltage output device Voltage output device Programmable Controllers ...

Page 87

... CS1W-PPS01 Isolated-type Pulse Input Unit Contact Input CS1W-PPS01 Isolated-type Pulse Input Unit Process I/O Units Voltage Input CS1W-PPS01 Isolated-type Pulse Input Unit Voltage pulse generation 3-wire Sensor Input CS1W-PPS01 Isolated-type Pulse Input Unit Internal power supply Internal power supply Internal power ...

Page 88

... CS1W-PMV01 Voltage Output CS1W-PMV01 Isolated-type Analog Output Unit Load Load Load Load CS1W-PMV02 + 334 Current Output CS1W-PMV01 Isolated-type Analog Output Unit Load resistance Load resistance Load resistance Load resistance CS1W-PMV02 Isolated-type Analog Output Unit A1 V1H V1L B1 A2 COM1 COM1 B2 A3 V2H ...

Page 89

... Voltage Output Unit Power Transducer Input CS1W-PTR01 8 inputs Unit Analog Input Unit CS1W-PTR02 8 inputs Note: Refer to pages 318 to 322 for descriptions of the Analog I/O Units (CS1W-AD0@@, CS1W-DA0@@, CS1W-MAD44.) Process I/O Units Field I/O I/O range/type Accuracy/effective resolution isolation All inputs Standard accuracy: 0.05% of full isolated ...

Page 90

... Overall Standard accuracy ±0.05% of full accuracy scale Temperature coeffi- ±0.01%/°C cient Cold junction ±1°C compensation error Connections Terminal block Note: Refer to page 326 for information on CS1W-PTS@@ Process I/O Units. 336 Circuit Configuration pts 8 pts 4 pts 4 pts Yes Yes --- ...

Page 91

C200H-TC@@@ Temperature Control Units One Unit Functions as Two Temperature Controllers • Supports 2-loop PID control (two degrees of free- dom) or ON/OFF control. • Input directly from two temperature sensors (ther- mocouples ...

Page 92

... Use Windows-based Support Software to easily cre- ate positioning data and store data and parameters in files. (Use WS01-NCTF1-E with C200HW-NC@ models and WS02-NCTC1-E with CS1W-NC@@ models.) • Interrupt feeding, forced starting, and other features also supported. ...

Page 93

... CS1W-MC421/-MC221 Motion Control Units High-precision, Two-axis Motion Control with Multi-tasking G-language Programming • High-speed control axes with one Unit and axes with one PLC (19 Units x 4 axes) (assumes that Power Supply Unit capacity is not exceeded). • Winding operations easily controlled at high-speed using traverse positioning control. • ...

Page 94

... Number of programs Program capacity CX-Motion: Windows-based Support Software Model WS02-MCTC1-EV@ Supported MC Units CS1W-MC221/421, C200H-MC221, and CV500-MC221/421 Applicable computer DOS, OS: Windows 95/98 or Windows NT Version 4.0 Functions Functions required for MC Unit control: Creating/editing/saving/printing system parameters, positioning data, and MC programs; moni- toring MC Unit operation ...

Page 95

C200HW-MC402-E Motion Control Unit Advanced multi-axes Motion Control with Multi-task BASIC language programming • Advanced Motion control of 4 axes per unit and modules can be installed in one PLC • Analogue outputs for position, Speed and ...

Page 96

Specifications General Model Classification Control Method Control Output signals Programming language Controlled axes Measurement units Positioning Linear interpolation Arc interpolation Helical interpolation Axes Synchronization Axes Linked CAM profile Hardware Registration Interrupt Task programming capacity Number of tasks Number of programs ...

Page 97

... Multi-axes control is made easy by freely combining control axes axes can be used, including 30 physical axes and two virtual axes, and each axis can be set individually. Position Control, synchronized control (electronic gear, electronic Cam, follow-up), speed control, and System Configuration CS1W-MCH71 motion control unit Sigma II or W-series servo drive ...

Page 98

... Mechatrolink-II Terminator Mechatrolink-II Cables 24V DC I/O Module Counter Module Pulse Output Module Specifications General Model CS1W-MCH71 Classification CS-series CPU Bus unit Applicable PLCs CS-series, new version (CS1[]-CPU[][]H) Control Method MECHATROLINK-II (Position, Speed and Torque control ) Controlled devices Sigma-II and W-series Servo Drives (ver later) with MECHATROLINK-II Interface and various I/O Units. ...

Page 99

... Digital variable noise filter provided. • 5-, 12-, and 24-V line driver inputs available. (5- and 12-V line driver input is only available, however, for 1 axis with the CS1W-CT021 and 2 axes with the CS1W-CT041.) • Supports simple, ring, and linear counting modes. • Supports offset phase input, up and down pulse input, and pulse+direction input. • ...

Page 100

... I0: 24V 5 I1: 24V 6 7 CH1: LD+ 8 CH1: 24V 9 CH1: LD+ 10 CH1: 24V 11 CH1: LD+ 12 CH1: 24V 13 14 CH3: LD+ 15 CH3: 24V 16 CH3: LD+ 17 CH3: 24V 18 CH3: LD+ 19 CH3: 24V 20 Unit numbers Model C200H-CT021 unit numbers CS1W-CT021 per Unit) CS1W-CT041 Programmable Controllers ...

Page 101

... CS1W-CTS21 SSI Encoder Input Unit SSI (synchronous serial interface standard communication protocol developed for absolute encoders. It provides easier connection and reduced wiring compared to parallel connection. Specifications SSI Communication Item Specification CLK lines Non-isolated differential line driver, RS422 compliant DATA lines Electrically isolated differential line ...

Page 102

Output Specifications Item Specification Driver Type Open Collector (NPN/PNP selectable) Operating Voltage Range 12-24 V (10.2 to 26.4 V) Maximum Switching Capacity 10 100 26.4 V (400mA max./common) (linear behaviour) ...

Page 103

... Yes munications SCB21-V1 Port 2: RS-232C Yes Boards/Units CS1W- Port 1: RS-232C Yes SCB41-V1 Port 2: RS-422A/485 Yes CS1W- Port 1: RS-232C Yes SCU21-V1 Port 2: RS-232C Yes Note: Requires SCU/SCB Ver 1.2 or later mounted on CS1 CPU Unit Ver 3.0. Host Link NT Links No-proto- Peripheral col ...

Page 104

C200H-ASC@@ ASCII Units Easily Perform Serial Data Communications • Perform ASCII communications with a wide range of external devices. • The C200H-ASC11/ASC21/ASC31 function as spe- cial processing units with BASIC programming. • Large-capacity user memory: 200 Kbytes • Model available ...

Page 105

... Set separately for each RS-232C x 2 port: RS-232C x 1, RS-422A/485 Protocol Macro, Host Link 1:N NT Link, Serial RS-232C x 2 Gateway or non-protocol communications. Programming Host computer Device PT Device Device Machine Microcomputer or Non-OMRON PLC other device Unit numbers Model --- CS1W-SCB21-V1 CS1W-SCB41- CS1W-SCU21-V1 351 ...

Page 106

... RS-232C or RS-422A/485 port without pro- gramming communications in the PLC. Standard system protocols are provided as a standard feature for com- munications with OMRON components, such as Temperature Control- lers, Panel Meters, Bar Code Readers, and Modems. A Windows- based tool called CX-Protocol is also available to enable creation of protocols for most any external device ...

Page 107

NT-AL001 RS-232C/RS-422A Adapter Unit Allows integration of RS232C devices into RS-422A networks. • Long-distance transmissions are possible through an RS-422A interface. By converting from RS-232C to RS-422A and then back to RS-232C, a transmis- sion distance 500 ...

Page 108

... C200H Special I/O Unit 354 One Read/Write Head can be connected to the CS1W-V600C11 and two Read/Write Heads can be connected to the CS1W-V600C12. The data transfer speed has been increased in both models. Data Carrier Connectable Read/ External power supply Unit numbers ...

Page 109

... Max. number of connectors Current consumption Dimensions Weight GP-IB Interface Unit Specification SYSMAC CS-series GP-IB Interface Unit CS1W-GPI01 CS1 Special I/O Unit CS1 CPU Rack or CS1 Expansion Rack GP-IB Interface Units per CPU Unit Number of unit numbers used: 1 Number of input words allocated: 5 ...

Page 110

... FINS messages on open network High-capacity remote I/O on open network (fixed or user allocations) High-capacity remote I/O on open network (user allocations) Freely configurable, object-oriented communication using CANopen or user-defined CAN protocols High-speed remote I/O with OMRON network (fixed allocations) Controller Link PROFIBUS-DP DeviceNet Yes Limited to DPV1 ...

Page 111

... CS1W-ETN@@ Ethernet Units Enables fast data transfer within Factory Automation systems, and easily links FA systems to plant management systems • Access socket services simply by manipulating specific bits in memory. • Take advantage of data transfer by e-mail. • Seamless communication with Controller Link and other networks. ...

Page 112

... PLC built-in clock, server/host name specification) Administration Floor FTP UDP/TCP socket Ethernet NS-series PT CX-Programmer FINS FINS FINS messages Wireless FINS Ethernet Unit Memory Card Connector Model 100Base-TX CS1W-ETN21 (10Base-T) CS1D-ETN21D Programmable Controllers ...

Page 113

... CS1W-CLK@@-V1, 3G8F7-CLK@@-V1, CS1W-RPT0@ Controller Link Units and PCI Boards OMRON’s efficient and easy-to-use FA Network • Achieve high-capacity, flexible data links. • Transfer large volumes of data through a message service. • Connect through twisted-pair cables or optical fiber cables. • Connect CS1, CJ1, C200HX/HG/HE and CQM1H PLCs. • ...

Page 114

... PCI bus) Controller Link Repeater --- Units Note: Lot numbers for the CS1W-CLK12-V1 and CS1W-CLK52-V1 are 030602 or later (June 2003 or later). Main Specifications Related to Version Upgrade for Unit Ver. 1.2 Item Number of data link words Data Link Area allocations User-set allocations ...

Page 115

... Handles data independent of the CPU unit, thus reducing CPU load Function The CS1W-PRM21 is a master system (DPM1). It exchanges I/O data and communication/status information with the CPU of the PLC. To configure the CS1W-PRM21 a serial port of the CPU can be used. But because configuring is done through FINS Specifications Model CS1W-PRM21 Main function Unit No ...

Page 116

... C200HW-PRT21 PROFIBUS-DP Slave Unit I/O Link Unit for C200H# and CS1 PLC Ideal for distributed control. • OMRON’s C200HS, C200HE, C200HG, C200HX and CS1 PLCs can be used as an intelligent Slave on a PROFIBUS-DP network. • Default 2 words words out, maximum 100 words in + 100 words out. ...

Page 117

... CS1W-DRM21-V1 DeviceNet Unit Multivendor Field Network • Control 32,000 points (2,000 words) per master. • Remote I/O communications can be allocated in any area using DM settings. • 16 DeviceNet Units can be mounted for each CPU Unit (3 max. for fixed allocations). • When using the Configurator (see note), remote I/O can be allocated in an order independent of node address ...

Page 118

... The maximum message length includes the command code when using the CMND instruction. 5. The CS1W–DRM21 cannot perform message communications with the E5ZE-8@D1@B. Use the E5ZE-8@D1@B-V2, which is a later ver- sion. For details on the E5ZE-8@D1@B-V2, refer to the catalog for the product itself (SGTD-017). ...

Page 119

... Function Supports messages that can be written to or read from the CS1/C200HX/HG/HE’s user I/O areas (i.e., IR, DM, HR, AR, LR, T/C, and EM areas) Master OMRON’s Master Unit or compatible unit from Rockwell Max. message size Slave (C200HW-DRT21) 200 bytes per READ or WRITE command ...

Page 120

C200HW-CORT21-V1 CAN & CANopen communication unit CAN & CANopen communication unit Supports CANopen, but can also be used to communicate with a user-defined CAN protocol • PDO’s configurable with CANopen Configurator or IOWR PLC instructions • Able to transceive any ...

Page 121

Specifications Installation Host PLC system Maximum number of Units per PLC system Unit mounting position Current consumption Network power supply Weight Environment Storage temperature Operating temperature Operating humidity Conformance to EMC- and environmental standards User Interface Switch settings Indicators PLC ...

Page 122

C200HW-SRM21-V1 CompoBus/S Master Unit CompoBus high-speed I/O bus • 256 I/O points per Master. • Slaves per Master. • Communications cycle time: 0.5 ms (at 750 kbps). • Communications distance 500 ...

Page 123

Communications Specifications Communications method Coding method Connection method Communications baud rate Communications High-speed communications cycle time mode Long-distance communications mode Communications cable Communications High-speed communications distance mode Long-distance communications mode Max. number of connecting nodes Error control checks Note: 1. ...

Page 124

... CS1W-BC102 CS1W-BC023 CS1W-BC033 CS1W-BC053 CS1W-BC083 CS1W-BC103 C200HW-PA204 C200HW-PA204S C200HW-PA204R U, C C200HW-PA209R C200HW-PD024 UC1 C200HW-PD106R U, C CS1W-IC102 HMC-EF372 L, CE HMC-EF672 HMC-AP001 CE CS1W-SCB21- CS1W-SCB41-V1 CQM1-PRO01 C200H-PRO27 CS1W-KS001-E CE CS1W-CN224 CS1W-CN624 *1 CX-ONE-AL@@C-E --- CS1W-CN118 CE CS1W-CN226 CS1W-CN626 XW2Z-200S-CV --- XW2Z-500S-CV XW2Z-200S-V XW2Z-500S-V CS1W-CIF31 --- CS1W-BAT01 L, CE Programmable Controllers ...

Page 125

... Controller Link Units Optical ring type with H-PCF cable Optical ring type with GI cable CX-One Omron's integrated software for programming and configuration of all control system components, including PLCs, HMI, drives, temperature controllers and advanced sen- sors. Optical Fiber Cable H-PCF cable for for interconnection between Duplex Controller Link Units, ...

Page 126

... CV500-CN122 Length CV500-CN222 Length CV500-CN322 Length CV500-CN522 Length CV500-CN132 Length CV500-CN232 Length CV500-CN332 Length CV500-CN432 Length CV500-CN532 Length: 0.3 m CS1W-CN311 Length: 0.7 m CS1W-CN711 Length CS1W-CN221 Length CS1W-CN321 Length CS1W-CN521 Length CS1W-CN131 Length CS1W-CN131-B2 Length: 0.3 m C200H-CN311 Length: 0.7 m C200H-CN711 Length C200H-CN221 ...

Page 127

... CS1W-ID261 6 CS1W-ID291 CS1W-IA111 UC1 CS1W-IA211 UC CS1W-INT01 UC1 CS1W-IDP01 1 CS1W-SF200 CS1W-OC201 UC1 CS1W-OC211 1 CS1W-OD211 1 CS1W-OD212 CS1W-OD231 UC1 CS1W-OD232 CS1W-OD261 UC1 CS1W-OD262 6 CS1W-OD291 CS1W-OD292 1 CS1W-OA201 UC CS1W-OA211 Inputs: 2 CS1W-MD261 UC1 Outputs Inputs: 2 CS1W-MD262 Outputs Inputs: 3 CS1W-MD291 Outputs: 3 Inputs: 3 CS1W-MD292 Outputs: 3 Inputs: 2 CS1W-MD561 UC Outputs: 2 373 ...

Page 128

C200H Basic I/O Units Classifica- Name Specifications tion C200H Input DC Input Units VDC, 8 inputs Yes Units (See 24 VDC, 16 inputs note 1.) AC Input Units 100 to 120VAC, 8 inputs 100 to 120VAC, 16 ...

Page 129

... Note: 1. Refer to page 384 (Wiring Devices) for details. (Square boxes indicate the cable length.) 2. The XW2Z-@@@D, CS1W-OD@@@, and C200H-OD@@@ cannot be connected. Only the inputs of the CS1W-MD@@@ can be connect- ed. Connectors for CS1 96-point I/O Units Part ...

Page 130

C200H High-density I/O Units Classified as Special I/O Units Name Specifications DC Input Units 24 V DC, 32 inputs TTL Input Units 5 V DC, 32 inputs Transistor Output Units 24 V DC, 32 sinking outputs TTL Output Units 5 ...

Page 131

Name Specifications Mountable Racks CPU Rack Heat/Cool Thermocouple input, Yes Temperature time-proportioning PID, Control Units or ON/OFF transistor output Thermocouple input, Yes time-proportioning PID, or ON/OFF voltage out- put Thermocouple input, Yes PID current output Temperature-resistance Yes thermometer input, time- ...

Page 132

... CV500-ZN3AT1-E --- CV500-CIF01 CVM1-PRO01 CV500-CN224 CE CVM1-MP702 XW2B-20J6-6 --- XW2Z-100J- C200HW-MC402 C200HW-NC113 C200HW-NC213 C200HW-NC413 --- CS1W-CN226 ( CS1W-CN626 (6 m) XW2Z-200S-CV --- (2 m) NCT V1.11 or earlier XW2Z-500S- NCT V1.11 or earlier XW2Z-200S (2 m) (See note 1.) XW2Z-500S (5 m) (See note 1.) XW2B-20J6-1B XW2B-40J6-2B XW2Z-050J-A6 (0.5 m) XW2Z-100J- XW2Z-050J-A7 (0.5 m) XW2Z-100J- XW2Z-050J-A8 (0 ...

Page 133

... UC1 CS1W-AD081- CS1W-AD161 UC1 CS1W-DA041 UC1 CS1W-DA08V CS1W-DA08C CS1W-MAD44 CS1W-PTS11 UC1, CE, N CS1W-PTS51 CE, UC1 CS1W-PTS55 UC1, CE CS1W-PTS12 UC1, CE, N CS1W-PTS52 UC1, CE CS1W-PTS56 CS1W-PTW01 UC1, CE CS1W-PDC01 CS1W-PDC11 UC1, CE, N CS1W-PDC55 CS1W-PPS01 UC1, CE CS1W-PMV01 CS1W-PMV02 CS1W-PTR01 CS1W-PTR02 CS1W-LC001 UC1 CS1W-LCB01 UC1 CS1W-LCO05 379 ...

Page 134

... CS1W-NC213 CS1W-NC413 CS1W-NC133 CS1W-NC233 CS1W-NC433 CS1W-CTS21 CS1W-MC421 CS1W-MC221 CS1W-MCH71 CS1W-CN226 ( CS1W-CN626 (6 m) XW2Z-200S-CV --- (2 m) XW2Z-500S- --- CVM1-PRO01 CV500-CN224 CE CVM1-MP702 XW2B-20J6-6 --- XW2B-40J6-7 XW2Z-100J- CS1W-SCU21- --- NT-AL001 --- CS1W-ETN21 UC1 CS1D-ETN21D CS1W-CLK21- CS1W-CLK12- CS1W-CLK52-V1 --- 3G8F7-CLK21-V1 CE 3G8F7-CLK12-V1 3G8F7-CLK52-V1 --- CJ1W-TB101 --- --- CS1W-RPT01 UC1, CE --- CS1W-RPT02 --- CS1W-RPT03 CS1W-GPI01 UC, CE Programmable Controllers ...

Page 135

... CAN communica- tion, or CANopen protocol Note 25-pin to 9-pin adapter is required to connected to a 9-pin, D-sub RS-232C connector on an IBM PC/AT or compatible. Note: Setting tool software for the Processing I/O Units also supports CS1W-AD@@@, CS1WS-DA@@@, and CS1W-MAD44. Optional Products Name Specifications Cover for 10-pin terminal block I/O Unit Cover Short protection for 10-pin terminal block (package of 10 covers) ...

Page 136

Mounting Rails and Accessories Name Specifications DIN rail Mounting Bracket 1 set (2 included) DIN rails Length: 50 cm; height: 7.3 cm Length height: 7.3 cm Length: 50 cm; height End Plate --- Spacer ALL DIMENSIONS ...

Related keywords