6ED1 052-2CC00-0BA5 SIEMENS, 6ED1 052-2CC00-0BA5 Datasheet - Page 80

no-image

6ED1 052-2CC00-0BA5

Manufacturer Part Number
6ED1 052-2CC00-0BA5
Description
MODULE, LOGO!, 24O
Manufacturer
SIEMENS
Datasheet

Specifications of 6ED1 052-2CC00-0BA5

No. Of Analogue Inputs
2
No. Of Analogue Outputs
2
No. Of Digital Inputs
8
No. Of Digital Outputs
4
Ip/nema Rating
IP20
Approval Bodies
CSA, FM, IEC, UL, VDE
Approval Category
External Depth
5
Central processing units
CPU 416F-2
Technical specifications (continued)
Forcing
• Status block
• Single step
• Number of breakpoints
Diagnostic buffer
Communication functions
• PG/OP communication
Global data communication
S7 basic communication
S7 communication
S5 compatible communication
Standard communication
Number of connections
1st interface
• Physical
• Isolated
Functionality
MPI
• Services
DP master
• Services
- Forcing
- available
- Number of inputs, max.
- adjustable
- preset
- supported
- Size of GD packets, max.
- supported
- User data per job
- supported
- as server
- as client
- User data per job, max.
- supported
- User data per job, max.
- Supported
- overall
- MPI
- DP master
- DP slave
- Number of connections
- PG/OP communication
- Routing
- Global data communication
- S7 basic communication
- S7 communication
- Transmission rates, max.
- Number of connections, max.
- PG/OP communication
- Routing
- S7 basic communication
5/4
SIMATIC S7-400
Siemens ST 70 News · 2006
6ES7 416-2FK04-0AB0
Yes
Yes
Yes
4
Yes
3,200
Yes
120
Yes
Yes
64 Byte
Yes; in MPI mode: via SFC
X_SEND, X_RCV, X_GET and
X_PUT
in DP master mode: via SFC
I_GET and I_PUT
76 Byte
Yes
Yes
Yes
64 KByte
Yes; via FC AG_SEND and
AG_RECV, via a maximum of
10 CP 443-1 or 443-5
8 KByte
Yes; via CP and loadable FB
64
RS 485 / PROFIBUS
Yes
Yes
Yes
Yes
44
Yes
Yes
Yes
Yes
Yes
12 Mbit/s
32; if a diagnostic repeater is
used in the chain, this reduces
the number of connection resour-
ces in the chain by 1
Yes
Yes
Yes
• Address area
• User data per DP Slave
DP slave
• Services
• Intermediate memory
2nd interface
• Physical
• Isolated
Functionality
DP master
• Services
• Address area
• User data per DP Slave
DP slave
• Services
- S7 communication
- Equidistance support
- Activate/deactivate DP slaves
- Direct data exchange
- Transmission rates, max.
- Number of DP slaves, max.
- Inputs, max.
- Outputs, max.
- Inputs, max.
- Outputs, max.
- Routing
- Status/modify
- Programming
- Transmission rates, max.
- Inputs
- Outputs
- Address areas, max.
- User data per address area,
- User data per address area,
- DP master
- DP slave
- Number of connections, max.
- PG/OP communication
- Routing
- S7 basic communication
- S7 communication
- Equidistance support
- Activate/deactivate DP slaves
- Direct data exchange
- Transmission rates, max.
- Number of DP slaves, max.
- Inputs, max.
- Outputs, max.
- Inputs, max.
- Outputs, max.
- Routing
- Status/modify
- Programming
- Transmission rates, max.
(lateral communication)
max.
of which consistent, max.
(lateral communication)
6ES7 416-2FK04-0AB0
Yes
Yes
Yes
Yes
12 Mbit/s
32
2 KByte
2 KByte
244 Byte
244 Byte
Yes
Yes
Yes
12 Mbit/s
244 Byte
244 Byte
32
32 Byte
32 Byte
RS 485 / PROFIBUS
Yes
Yes
Yes
32; if a diagnostic repeater is
used in the chain, this reduces
the number of connection
resources in the chain by 1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
12 Mbit/s
125
8 KByte
8 KByte
244 Byte
244 Byte
Yes
Yes
Yes
12 Mbit/s

Related parts for 6ED1 052-2CC00-0BA5