Specifications of LRD04

Overload Adjustment Current Min
0.4A
Overload Adjustment Current Max
0.63A
Approval Bodies
CSA, UL
Contact Current Max
5A
External Depth
70mm
External Length / Height
51mm
External Width
45mm
Contact Form
1 NO, 1 NC
Current, Rating
0.63 A
Current, Rating Max
0.63
Function
Overload
Mounting Type
Clamp
Primary Type
Contactor
Relay Type
Electro Mechanical
Terminal Type
Screw
Termination
Screw
Voltage, Control
575 VAC
2.3
2
Description,
characteristics
1
2
3
4
5
6
7
8
Conforming to standards
Product certifications
Degree of protection
Protective treatment
Ambient air temperature
around the device
(conforming to IEC 255-8)
Maximum operating altitude
Operating positions
without derating
Shock resistance
Vibration resistance
Dielectric strength at 50 Hz
Impulse withstand voltage
Resistance to electrostatic discharge
Resistance to radio-frequency
conducted disturbances
Resistance to fast transient currents Conforming to IEC 1000-4-4
Electromagnetic compatibility
Conventional thermal current
Maximum consumption
of operating coils
of controlled contactors
(Occasional operating cycles
of contact 95-96)
Short-circuit protection
Cabling
Flexible cable without cable end
References:
pages 2/112 and 2/113
2/110
Description
Environment
Electrical characteristics of auxiliary contacts
Setting dial Ir
Test button
Stop button
Reset button
Trip indication
Setting locked by sealing the cover
Class 10/class 20 selector
Selector for balanced load
unbalanced load
Dimensions:
pages 2/116 to 2/118
/
LR9-D electronic thermal overload relays are designed for use with contactors LC1-D115 and D150.
In addition to the protection provided by model d thermal overload relays (see page 2/108 ) they offer the following
special features:
p Protection against phase imbalance.
p Choice of starting class.
p Protection of unbalanced circuits.
p Protection of single-phase circuits.
p Alarm function to avoid tripping by load shedding.
(1) For operation at 70 ˚C, please call our Customer information centre on 0870 608 8 608.
LR9-D5367…D5569
Conforming to IEC 529 and VDE 0106
Standard version
Storage
Normal operation
Without derating
In relation to normal, vertical
mounting plane
Permissible acceleration
conforming to IEC 68-2-27
Permissible acceleration
conforming to IEC 68-2-6
Conforming to IEC 255-5
Conforming to IEC 1000-4-5
Conforming to IEC 1000-4-2
Conforming to IEC 1000-4-3
and NF C 46-022
Draft EN 50081-1 and 2, EN 50082-2
a.c. supply
d.c. supply
By gG or BS fuse
or by GB2 circuit-breaker
1 or 2 conductors
Tightening torque
107
90
150
127
Ir(A)
TeSys protection components
3-pole electronic thermal overload relays LR9-D
Schemes:
page 2/119
98
NO
97
˚C
˚C
m
kV
kV
kV
V/m
kV
A
V
VA
V
W
A
mm
N.m
95
2
NC
96
EN 60947-4-1, 255-8, 255-17, VDE 0660
UL 508 , CSA 22-2
IP 20 on front face
with protective covers LA9-D11570p or D11560p
"TH"
- 40…+ 85
- 20…+ 55 (1)
2000
Any position
13 gn - 11 ms
2 gn - 5 to 300 Hz
6
6
8
10
2
Meets requirements
5
24
100
24
100
5
Minimum c.s.a.: 1/maximum c.s.a.: 2.5
1.2
1
2
5
4
3
6
48
200
48
100
LR9-D67 and D69
107
90
150
127
Ir(A)
110
400
110
50
+
24 V - / 103
20
10
Class
104
Load
Alarm
220
600
220
45
98
Schneider Electric
380
600
440
25
NO
97
95
NC
600
600
96
7
8
2
5
4
3
1
6

Related parts for LRD04