IQ12050QTC20NRS-G SYNQOR, IQ12050QTC20NRS-G Datasheet
IQ12050QTC20NRS-G
Specifications of IQ12050QTC20NRS-G
Related parts for IQ12050QTC20NRS-G
IQ12050QTC20NRS-G Summary of contents
Page 1
... IQ12050QTC20 (5.0V, 20A) Characteristics and Figures . . . . . . . . IQ12070QTC14 (7.0V, 14A) Characteristics and Figures . . . . . . . . IQ12120QTC08 (12V, 8.0A) Characteristics and Figures . . . . . . . . IQ12150QTC07 (15V, 7.0A) Characteristics and Figures . . . . . . . . IQ12240QTC04 (24V, 4.0A) Characteristics and Figures . . . . . . . . IQ12300QTC03 (30V, 3.0A) Characteristics and Figures . . . . . . . . IQ12480QTC02 (48V, 2.0A) Characteristics and Figures . . . . . . . . Application Notes Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 www.synqor.com Doc.# 005-IQ12QTX Rev. C Technical Specification IQ12-QTC Family 2250 V dc Quarter-brick DC-DC Converter Isolation Page No ...
Page 2
... Notes: 1. SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2. Leave TRIM pin open for nominal output voltage. 3. SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-IQ12QTX Rev. C Technical Specification IQ12-QTC Family Side View 0.18 (4.57) 0.500 ± 0.025 (12.7 ± 0.63) Overall Height 0.010 ± 0.010 (0.25 ± ...
Page 3
... Technical Specification IQ12-QTC Family Units notes & Conditions 30 V Continuous 22 V Continuous 25 V 100 ms transient, square wave Basic insulation, Pollution Degree 2 Vdc Vdc Vdc °C Baseplate temperature ° transient for 100 V µF Typical ESR 0.1-0.2 W ...
Page 4
... IQ12 FaMIly STanDaRDS anD QUalIFICaTIOnS (all output voltages °C, airflow rate = 300 LFM temperature with appropriate power derating. Specifications subject to change without notice. STANDARDS COMPLIANCE Parameter STANDARDS COMPLIANCE UL/cUL 60950-1 EN60950-1 Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. QUALIFICATION TESTING Parameter QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability ...
Page 5
... Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points. 1,000,000.0 100,000.0 10,000.0 1,000 Common Figure 4: Trim graph for trim- outputs. www.synqor.com Technical Specification IQ12-QTC Family Typical Current Limit Inception Point Typical Output Voltage at Shutdown Vin, Min. Vin, Typ. Vin, Max ...
Page 6
... Input: 9-22 V Output: 1.8 V Current Part no.: IQ12018QTC40 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load ...
Page 7
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output: 1.8 V Current Part no ...
Page 8
... Input: 9-22 V Output: 3.3 V Current Part no.: IQ12033QTC30 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV ...
Page 9
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output: 3.3 V Current Part no ...
Page 10
... Input: 9-22 V Output: 5.0V Current Part no.: IQ12050QTC20 ) OUT Units notes & Conditions trim up; in current limit 300 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV ...
Page 11
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output: 5.0V Current Part no ...
Page 12
... Input: 9-22 V Output: 7.0 V Current Part no.: IQ12070QTC14 ) OUT Units notes & Conditions trim up; in current limit 300 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV ...
Page 13
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output: 7.0 V Current Part no ...
Page 14
... Input: 9-22 V Output Current Part no.: IQ12120QTC08 ) OUT Units notes & Conditions Vout; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load ...
Page 15
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output Current Part no ...
Page 16
... Input: 9-22 V Output Current Part no.: IQ12150QTC07 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load ...
Page 17
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic and 15 µF tantalum (500 mV/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output Current Part no ...
Page 18
... Input: 9-22 V Output Current Part no.: IQ12240QTC04 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load ...
Page 19
... Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). (1 V/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output Current Part no ...
Page 20
... Input: 9-22 V Output Current Part no.: IQ12300QTC03 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load ...
Page 21
... Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). (1 V/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output Current Part no ...
Page 22
... Input: 9-22 V Output Current: 2A Part no.: IQ12480QTC02 ) OUT Units notes & Conditions trim up; in current limit 250 V/ms input transient; 100 µF output cap. mA RMS A Fast acting external fuse recommended µH\µF Internal values; see Figure Over sample, line, load, temperature & life 20 MHz bandwidth mV Full Load mV Full Load ...
Page 23
... LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 6: Output voltage response to step-change in input voltage (250 V/ms). µF ceramic capacitor V/div Vin (10 V/div). www.synqor.com Input: 9-22 V Output Current: 2A Part no ...
Page 24
... Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. ON/OFF Vin TTL/ ON/OFF CMOS Vin Direct Logic Drive www.synqor.com Technical Specification IQ12-QTC Family ] [V V Vout(+) - Vout(-) – sense(+) - Sense Range % x Vout 50k ON/OFF 50k ...
Page 25
... The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart , due OUT Hysteresis value. www.synqor.com Technical Specification IQ12-QTC Family Doc.# 005-IQ12QTX Rev. C 09/23/08 Page 25 ...
Page 26
... APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. application Circuits: Figure D provides a typical circuit diagram which details the input filtering and voltage trimming ...
Page 27
... For convenience, Figures 3 and 4 provide Power derating curves For convenience, Figures 3 and 4 provide Power derating curves for an encased converter without a heatsink and with a typical for an encased converter without a heatsink and with a typical 1/4" high heatsink. 1/4" high heatsink the chosen heatsink , of the chosen heatsink OFF OFF ON ON 200ms 200ms www.synqor.com Doc.# 005-IQ12QTX Rev. C Technical Specification IQ12-QTC Family 100 º 100 º max max diss diss OFF ...
Page 28
... Warranty SynQor offers a three (3) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. www.synqor.com Doc.# 005-IQ12QTX Rev. C ...