LS15024 TDK Corporation, LS15024 Datasheet

POWER SUPPLY, AC/DC, 24V

LS15024

Manufacturer Part Number
LS15024
Description
POWER SUPPLY, AC/DC, 24V
Manufacturer
TDK Corporation
Datasheet

Specifications of LS15024

Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
6.5A
Power Rating
156W
Input Voltage
88V AC To 132V AC / 176V AC To 264V AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(1)
(2)
S p e c i f i c a t i o n s
ITEMS
AC Input Voltage (300VAC for 5s)
Input Frequency
DC Input Voltage
Inrush Current (230VAC, cold start)
Power Factor
Input Current (115/230VAC)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (115 / 230V input)
Leakage Current (230VAC 60Hz)
Remote Sense
LED Indicator
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Immunity
Safety Agency Approvals
Conducted & Radiated EMI
MTBF (MIL-HDBK-217F)
Weight (Typ)
Size (LxWxH)
Warranty
Switch selectable for 115 or 230VAC
LS25-3
LS50, LS75-3 & -5
LS75-12, -15, -24, -36, -48
LS100-3 & -5
LS100-12, -15, -24, -36, -48
LS150-3 & -5,
LS150-12, -15, -24, -36, -48
Derate linearly to 60% load from +40 to +70°C.
Derate linearly to 70% load from +50 to +70°C.
Derate linearly to 60% load from +50 to +70°C.
Derate linearly to 60% load from +45 to +70°C. Derate linearly to 80% load from 115V to 88VAC input.
Derate linearly to 60% load from +50 to +70°C. Derate linearly to 80% load from 115V to 88VAC input.
Derate linearly to 50% load from +40 to +70°C.
Derate linearly to 70% load from +50 to +70°C.
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
VDC
VAC
mA
hrs
ms
yrs
Hz
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.1 x 2.0 x 1.1
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
0.7 / 0.4
906,997
14 / 80
LS25
170
30
Single Output General Purpose Power Supplies
3.3V: 3.8-4.45V, 5V: 5.75-6.75V, 12V: 13.8-16.2V, 15V: 17.25-20.25V,
-25 to +70°C. Derate linearly to 50% load from +50 to +70°C (2)
10 - 55Hz: 19.6m/s
3.9 x 3.2 x 1.4
0.8 / 0.55
706,464
>100M at 25C & 70%RH, Output to Ground 500VDC
12 / 80
24V: 27.6-32.4V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
LS35
270
40
UL60950-1, EN60950-1, IEC60950-1, CE Mark
88 - 264VAC (See note (2) for LS100)
Test & Measurement
Automated Service
IEC61000-4-2, -3, -4, -5, -6, -8, -11
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Very low cost
Small size
115VAC or 230VAC input
Withstands 300VAC surges (5s)
Three year warranty
20 - 90% RH (non condensing)
10 - 95% RH (non condensing)
EN55011/EN55022-B, FCC-B
125 - 373VDC
3.9 x 3.8 x 1.4 5.1 x 3.8 x 1.5
Meets EN61000-3-2, -3
1.3 / 0.8
712,890
14 / 60
2
< 196.1 m/s
LS50
350
LS Series
constant sweep 1 min X, Y, Z for 1 hour
40
Green LED = On
-40 to +85°C
<0.02%/°C
Three Years
Convection
47 - 63Hz
> 110%
<1mA
No
2
1.6 / 1.0
648,786
14 / 60
(20G)
LS75
410
40
6.3 x 3.8 x 1.5
2.2 / 1.2
25 / 150
545,375
LS100
600
60
88-132/176-264VAC(1)
248 - 273VDC
7.8 x 3.9 x 1.5
505,393
20 / 28
3.5 / 2
LS150
700
40
59

Related parts for LS15024

LS15024 Summary of contents

Page 1

ITEMS AC Input Voltage (300VAC for 5s) VAC Input Frequency Hz DC Input Voltage VDC Inrush Current (230VAC, cold start) A Power Factor - Input Current ...

Page 2

Adjust Range Model Voltage LS25-3.3 3.3V 2.85 - 3.6 LS25-5 5V 4.5 - 5.5 LS25-12 12V 10.8 - 13.2 LS25-15 15V 13.5 - 16.5 LS25-24 24V 22 ...