NV1350FF TDK Corporation, NV1350FF Datasheet

POWER SUPPLY, SWITCH MODE, 5V

NV1350FF

Manufacturer Part Number
NV1350FF
Description
POWER SUPPLY, SWITCH MODE, 5V
Manufacturer
TDK Corporation
Type
Medicalr
Datasheet

Specifications of NV1350FF

Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
3
Output Voltage
5V
Output Current
25A
Power Rating
175W
Input Voltage
90V AC To 264V AC
Length
127mm
Width
76.2mm
Brand/series
NV135 Series
Configuration
Open-Frame
Current, Input
25 A
Current, Leakage
300 uA (Max.) @ 264 VAC⁄63 Hz
Efficiency
90% (Max.) Configuration Dependant
Frequency
47 to 63 Hz
Mounting Type
Panel
Number Of Outputs
3
Operation
Linear
Output
-15 VDC @ 1 A, +5 VDC @ 25 A, +15 VDC @ 5 A
Power, Output
175 W
Primary Type
AC-DC
Special Features
PFC, Remote Sense
Standards
UL Listed, CSA Cerified, EN and IEC Approved
Temperature, Ambient
0 °C
Voltage, Input
90 to 264 VAC
Voltage, Output
-15, +5, +15 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
S p e c i f i c a t i o n s
F e a t u r e s a n d B e n e f i t s
Feature
ITEMS
Input Voltage range
Inrush Current
Power Factor Harmonics
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise
Efficiency
Minimum Load
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
DC Good (Specify N option)
Remote On/Off (Specify N option)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Isolation
Vibration (non operating)
Shock
Safety Agency Approvals
Immunity
Conducted Emissions and Flicker
Radiated Emissions
Weight (Typ)
Size
Warranty
Notes: (1) -20°C cold start
High Efficiency
Low Profile
Power Factor Corrected
No Minimum Loads
MODEL
(3)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mA
mV
ms
yrs
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC
UL60950-1, CSA22.2 No 60950-1, EN60950-1, IEC60950-1, CE for LVD,
NV175 Series
(2) See application note for Class B
0 to +70°C. Derate linearily to 50% load from 50°C to 70°C(1)(7)
2G, 10-500Hz (sweep & endurance at resonance) in all 3 planes
EN61000-6-2:2001, EN61000-4-2, -3, -4, -5, -6, -8, -11
TTL logic level high will inhibit all outputs (except Standby)
On Outputs CH1 & CH2, 0.5V compensation maximum
3” x 5” x 1.25” (3.7” x 5” x 1.25” for N option version)
IEC60601-1, EN60601-1, EN61010-1, IEC61010-1
90 - 264VAC (47 - 63Hz, 440Hz with reduced PFC)
EN55022 Class B (per CISPR.22), EN61000-3-3
CH1 & CH2, 120-130%, Cycle AC line to reset
<40A at 25°C and 264VAC input, Cold Start
< 0.1% for 100% load change on any output
CH1 Only, High on Fail (<95% of nominal)
Benefit
< 0.1% for 90-264VAC input change
Forced air, 2m/s from input to output
Broadcast
Test & Measurement
Medical
Industrial Computing and Routers
Up to 90%, configuration dependant
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
1% or 50mV (Which ever is greater)
EN55022 Class A (per CISPR.22)(2)
Less heat dissipated in system
Fits in 1U enclosures
Supports Global Use
Ease of Use
< 1% for 0-100% load change
300µA max at 264VAC, 63Hz
EN61000-3-2 Compliant
1-5 Outputs
Up to 90% Efficient
Active Power Factor Correction
Universal Input (90 - 264VAC)
No Minimum Loads
Medical Approvals
>16ms at 90VAC Input
30G per IEC68-2-27
3” x 5” 175W Power Supplies
-40 to +85°C
5 - 95% RH
Three Years
>105%
NV175
None
250g
Yes
(3) Including underside component leads

Related parts for NV1350FF

NV1350FF Summary of contents

Page 1

Feature High Efficiency Low Profile Power Factor Corrected No Minimum Loads ...

Page 2

... NV1452FFN +5V/25A +2.7V/15A +15V/ 5.5V) (2.5 - 3.3V) (12 - 15V) NV1350TTN +5V/25A - +12V/ 5.5V) (12 - 15V) NV1350FFN +5V/25A - +15V/ 5.5V) (12 - 15V) NV1250T0N +5V/25A - +12V/ 5.5V) - (12 - 15V) Notes: (4) Maxium combined current from CH1 + CH2 = 25A (5) CH5 is a standby Voltage (always On). 2.5A Peak rated (6) Non-stocked model (7) Convection cooled maximum ratings: CH1: 55W, CH2: 8 ...