TXL 035-0524D TRACOPOWER, TXL 035-0524D Datasheet

Power Supply, +5V

TXL 035-0524D

Manufacturer Part Number
TXL 035-0524D
Description
Power Supply, +5V
Manufacturer
TRACOPOWER
Datasheet

Specifications of TXL 035-0524D

Power Supply Type
Enclosed
Power Supply Output Type
Variable
No. Of Outputs
2
Output Voltage
+5V
Output Current
4A
Power Rating
35W
Input Voltage
85V AC To 264V AC / 120V DC To 375V DC
Length
99mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
http://www.tracopower.com
Models with Single Output
Compact metal case with
screw terminal block
Dual and triple output models with
isolated outputs
Universal input 85–264 VAC
EMI/EMC compliance with EN 61000-6-3
and EN 61000-6-1
Compliance to EN 61000-3-2 (PFC)
Short circuit and overvoltage protection
International safety approvals
3-year product warranty
TXL 015-3.3S
TXL 025-3.3S
TXL 035-3.3S
TXL 015-05S
TXL 015-12S
TXL 015-15S
TXL 015-48S
TXL 025-05S
TXL 025-12S
TXL 025-15S
TXL 025-48S
TXL 035-05S
TXL 035-12S
TXL 035-15S
TXL 035-48S
TXL 050-05S
TXL 060-12S
TXL 060-15S
TXL 015-24S
TXL 025-24S
TXL 035-24S
TXL 060-24S
Order Code
Case Type
C
B
D
Enclosed Power Supplies
TXL Series, 15 –1000 Watt
The TRACOPOWER TXL series is a family of encased power supplies designed for
a wide range of cost critical applications. With a low profile metal case and screw
terminal block connection, they are easy to install in any equipment.
There are 69 models in this range with single, dual, and triple output voltages from
3.3 VDC to 48 VDC in 12 power ranges from 15 W to 1000 W. These power sup-
plies have universal input and comply with European EMC standards and the Low
Voltage Directive (LVD).
Output Power max.
50 / 60 Watt
15 Watt
25 Watt
35 Watt
Output Voltage nom.
3.3 VDC
3.3 VDC
3.3 VDC
12 VDC
15 VDC
24 VDC
48 VDC
12 VDC
15 VDC
24 VDC
48 VDC
12 VDC
15 VDC
24 VDC
48 VDC
12 VDC
15 VDC
24 VDC
5 VDC
5 VDC
5 VDC
5 VDC
Output Current max.
0.63 A
0.32 A
0.57 A
0.75 A
10.0 A
5.0 A
3.0 A
3.0 A
1.3 A
1.0 A
6.0 A
5.0 A
2.1 A
1.7 A
1.1 A
9.0 A
7.0 A
3.0 A
2.4 A
1.5 A
4.0 A
2.5 A
Page 1 of 10

Related parts for TXL 035-0524D

TXL 035-0524D Summary of contents

Page 1

... TXL 025-05S TXL 025-12S TXL 025-15S TXL 025-24S TXL 025-48S TXL 035-3.3S TXL 035-05S TXL 035-12S TXL 035-15S TXL 035-24S TXL 035-48S TXL 050-05S TXL 060-12S TXL 060-15S TXL 060-24S http://www.tracopower.com Enclosed Power Supplies TXL Series, 15 –1000 Watt The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications ...

Page 2

... TXL 220-48S TXL 300-24S TXL 300-48S TXL 600-24S TXL 600-48S TXL 1000-24S TXL 1000-48S Models with Multiple Output Order Code Case Type TXL 035-0512D TXL 035-0524D D TXL 035-1212D TXL 035-1515D TXL 060-0512DI TXL 060-0524DI TXL 060-0521TI E TXL 060-0522TI TXL 060-0533TI TXL 060-0534TI ...

Page 3

... Output voltage adjustment range Regulation – Input variation – Load variation (10–100%) – Minimum load on main output of multiple output models: 0.3 A for TXL 035 (to provide the regulation on the auxilary outputs) Ripple and noise (20 MHz bandwidth) Output current limitation Overload protection mode Over voltage protection (only output 1) Capacitive load, max ...

Page 4

... Safety approvals – UL/cUL Casing material All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Enclosed Power Supplies TXL Series 60–100 Watt multiple output models: 500 VAC (for all outputs of triple output models!) 35 Watt dual output models: outputs not isolated TXL 025/035 nickel plated steel (chassis & ...

Page 5

... –Vout Common 5 +Vout Vout con. Vout 2 Weight: 0.3 kg (10 oz) Max mounting screw penetration: 2.0 mm (0.08) http://www.tracopower.com Enclosed Power Supplies TXL Series 2x M3 THD 39.1 (1.54) 14 max. 62 (2.44) (0.55 max.) Top view L N Vout + 39.1 (1.54 THD 65 (2.56) 14 max. 79 (3.11) (0 ...

Page 6

... Opposite polarity for TXL 100-0534TI Dual & Triple output models Weight: 0.8 kg (28 oz) Max mounting screw penetration: 3.0 mm (0.12) http://www.tracopower.com 10 max. (0.39 max.) 1 Top view Single output Dual & Triple output models ...

Page 7

... Case Dimensions Case K Weight: 0.82 kg (29 oz) Case L 13 max. (0.51 max Vout N L Weight: 0. oz) Max mounting screw penetration: 3.0 mm (0.12) http://www.tracopower.com THD 117 (4.61) 12 max. 178 (0.47 max.) (7.01) Top view THD + (bottom ) + Vout (2.17 THD 117 (4.61) 176.5 (6 ...

Page 8

... Vout N L Weight: 0. oz) Case O 12 max. (0.47 max Vout N L Weight: 1.05 kg (37 oz) Max mounting screw penetration: 3.0 mm (0.12) http://www.tracopower.com THD 117 56 (4.61) 176.5 (6.95) 198 (7.8) Top View THD (bottom THD (bottom (2.56) (2.48) 168 (6.61) ...

Page 9

... M3 THD (bottom & cover) Max mounting screw penetration: 3.0 mm (0.12) Weight: 2.3 kg (81 oz) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com 220 (8.66 THD (front- & backside) 275 (10.83) 240 (9 ...

Page 10

... Monting hole pich tolerances ±0.5 (±0.02) Caution! Max mounting screw penetration: 3.0 mm (0.12) Specifications can be changed any time without notice. Jenatschstrasse 1 · CH-8002 Zurich · Switzerland Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · info@traco.ch · www.tracopower.com 271.7 (10.70) 239.5 (9.43) ...