... MINI-PS-100-240AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet MINI POWER provides: – An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) – Global use due to a wide-range input – A high level of operational safety in complex global networks – ...
Page 2
... MINI-PS-100-240AC/10-15DC/8 Technical Data Input Data Nominal input voltage (wide-range input) Input voltage range Frequency Current consumption (for nominal values) 2 Inrush current limiting/I t (+25°C [+77°F]) Mains buffering for a nominal load (typical) Switch-on time after applying the mains voltage Transient surge protection ...
Page 3
... IEC 60068-2-6 Shock (in all space directions) according to IEC 60068-2-27 Degree of pollution according to EN 50178 Climatic category according to EN 60721 102046_00_en MINI-PS-100-240AC/10-15DC/8 EN 60204 EN 61558-2-17 EN 60950/VDE 0805, UL/C-UL Recognized UL 60950 u UL/C-UL Listed UL 508 U EN 50178/VDE 0160 PELV (EN 60204)/SELV (EN 60950) VDE 0100-410 ...
Page 4
... MINI-PS-100-240AC/10-15DC/8 Conformance With EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC Noise Immunity Test According to EN 61000-6-2 Electrostatic discharge (ESD) Electromagnetic HF field Fast transients (burst) Surge current loads (surge) Conducted interference Voltage dips Noise Emission Test According to EN 61000-6-3 Radio interference emission ...
Page 5
... Device connections and control elements 1 AC input: Input voltage 85 - 264 V AC, frequency output: Output voltage (default), can be set from using potentiometer 3 Active DC OK switching output 4 Potentiometer Green DC OK LED 102046_00_en MINI-PS-100-240AC/10-15DC/8 Order Designation MINI-PS-100-240AC/10-15DC/8 6 Universal latching foot for EN DIN rails Order No ...
Page 6
... MINI-PS-100-240AC/10-15DC/8 Installation Safety Notes and Warning Instructions Installation and startup must only be carried out by qualified personnel. The relevant country-specific regulations (e.g., VDE, DIN) must also be observed. Before startup it is particularly important to ensure that: – The mains has been connected correctly and protection is provided against electric shock. ...
Page 7
... To ensure sufficient convection, a minimum spacing (1.969 in.) to other modules is required above and below the device. Mounting on the DIN Rail Figure 2 DIN rail mounting/removal The power supply unit can be snapped onto all 35 mm (1.378 in.) DIN rails according to EN 60715. The device should be mounted horizontally (input terminal blocks facing downwards). 102046_00_en MINI-PS-100-240AC/10-15DC/8 7 ...
Page 8
... MINI-PS-100-240AC/10-15DC/8 Connection/Connecting Cable The device is equipped with COMBICON connectors. This connection method enables quick device connection and visible isolation of the electrical connection, if required. Connectors may only be operated when the power is switched off. Solid [mm Input/output/signal 0.2 - 2.5 To maintain UL approvals, use copper cables, which are designed for operating temperatures > ...
Page 9
... If the internal fuse is blown, this is most probably due to a device fault. In this case, the device should be checked in the factory. 102046_00_en MINI-PS-100-240AC/10-15DC/8 (TN network according to VDE 0100-300/IEC 60364-3) with nominal voltages of 100 - 240 V AC (see Figure 5). 9 ...
Page 10
... MINI-PS-100-240AC/10-15DC/8 Output The connection is made using the "+" and "-" screw connections (see Figure 1, point 2). The output voltage set upon delivery DC. The output voltage can be adjusted from the potentiometer. The active DC OK switching output (see Figure 1, point 3) is connected using the "DC OK" and "-" screw connections ...
Page 11
... Active +12 V (with reference to "-") switching output Meaning Normal operation of the power supply unit U > 10.8 V OUT Figure function monitoring 102046_00_en MINI-PS-100-240AC/10-15DC/8 Status 2 OFF (with reference to "-" OUT – Secondary load short circuit or overload – No mains voltage or device fault ...
Page 12
... MINI-PS-100-240AC/10-15DC/8 Parallel and Redundancy Operation Parallel Operation A maximum of five devices can be connected in parallel. Devices of the same type can be connected in parallel to increase both redundancy and power. The default setting does not have to be adjusted. If the output voltage is adjusted, an even current distribution can be ensured by precisely setting all power supplies that are operated in parallel to the same output voltage ...
Page 13
... MINI-PS-100-240AC/10-15DC/8 Make sure you always use the latest documentation. It can be downloaded from www.phoenixcontact.com. Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + + www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork 13 102046_00_en ...