EA-IF-PB1 EA ELEKTRO-AUTOMATIK, EA-IF-PB1 Datasheet - Page 62

no-image

EA-IF-PB1

Manufacturer Part Number
EA-IF-PB1
Description
PSU, INTERFACE, PROFIBUS
Manufacturer
EA ELEKTRO-AUTOMATIK
Datasheet

Specifications of EA-IF-PB1

Accessory Type
Interface Cards
Svhc
No SVHC (18-Jun-2010)
Applications
Engineering Laboratory And Complex Industrial Application
Approval Bodies
CE / EN
Rohs Compliant
Yes
For Use With
EA Elektro-Automatik PSU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
About the interface cards
© 009, Elektro-Automatik GmbH & Co. KG
Digital inputs
The interface card IF-A1 has three parameterisable digital
inputs DI1, DI and DI3(not used, reserved).
DI1/SEL_enable
After the external control has been actived, the power supply
can be controlled by the inputs VSEL, CSEL and/or PSEL.
The status signale and analogue actual values are always
put out.
control by the analogue interface.
DI/Rem-SB
You can switch the power supply output on and off, enable
or block it with this input. Depending on the setting
output, the input DI/Rem-SB determines whether the out-
put is controlled exclusively in external mode (by analogue
interface) respectively remote mode (by digital interface) or if
it requires to be enabled by the
indicated in the display with
On/Off setting, the power output is directly controlled by the
input DI/Rem-SB. Attention! This can‘t be interrrupted by
the
interface card (exception: the device is in „local“ mode, then
the input is ignored).
DI2/Rem-SB
When using the setting
enabled at least once. By the setting
(see configuration menu of your device) the power output
will be automatically enabled after a mains loss, if it has
been enabled before the mains loss occured. It can then be
switched on or off as normal.
Note: the power supply output can always (exception: explicit
local mode) be shut down with the input DI/Rem-SB, even
if external mode is not active.
Set output
external
extern
ON/OFF
= LOW
= HIGH
= enable ON
= exclusive
The display indicates, that the device is in external
key on the front or by a command from a digital
External control of the device by IF-A1 is low
active. If the default logical level of DI1 is set to
LOW by the jumper on the PCB, the external
control will be instantly active when switching
the device on.
External control of the device by IF-A1 is high
active.
The
enable the input
The power supply output can only be
switched on and off by the input DI/
Rem-SB or via a digital interface card
(if equipped)
enable
ON/OFF
auto
ON/OFF
ON,
ON. Using the exclusive
key has to be used to
the output needs to be
Default:
Power ON = restore
Default:
key. The enabling is
enable ON
LOW
Set
Standby
The figure shows the chaining of the various states and con-
ditions for local, remote and external mode when switching
the power output on or off:
Jumper settings for DI1-3
The jumpers DI1-3 on the PCB are used to preset the phy-
sical behaviour of these inputs. The selector „Default level“
defines the default logical level of the corresponding input.
That means, if the default logical level is set to High, the input
has to be pulled actively to Low by an external application
(eg. relay) in order to change its logical level. The default
logical level requires attention, since it defines the behaviour
of the power supply by the control signals SEL_enable and
Rem-SB.
Default level defines the logical level of the input if not
wired.
High range selects the high input voltage range for the
input. A „high“ corresponds to a voltage of >9V and a „low“
to a voltage of <5V.
Low range selects the low input voltage range for the input.
A „high“ corresponds to a voltage of >4V and a „low“ to a
voltage of <1V.
= LOW
= HIGH
The input is low active, standby is activated
with a voltage level <1V or <5V (depending
on the jumper setting)
The input is high active, standby is activated
with a voltage level >4V or >9V (depending
on the jumper setting).
Default:
LOW
EN