EA-MEC PB 300-12C EA ELEKTRO-AUTOMATIK, EA-MEC PB 300-12C Datasheet

INVERTER, DC/AC, 12VDC/230VAC

EA-MEC PB 300-12C

Manufacturer Part Number
EA-MEC PB 300-12C
Description
INVERTER, DC/AC, 12VDC/230VAC
Manufacturer
EA ELEKTRO-AUTOMATIK
Datasheet

Specifications of EA-MEC PB 300-12C

No. Of Outlets
1
Input Voltage
11VDC To 16VDC
Supply Voltage Typ
12VDC
Output Power
300VA
Output Voltage
230V
Length
62mm
Width
285mm
Height
120mm
Weight Min
1.75kg
Svhc
No SVHC (18-Jun-2010)
Weight
1.75kg
Rohs Compliant
Yes
Efficiency
90%
External Depth
285mm
External Length / Height
62mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technische Daten Technical Data MEC-PB 150-12B MEC-PB 150-12C MEC-PB 150-24B MEC-PB 150-24C MEC-PB 300-12B MEC-PB 300-12C MEC-PB 300-24B MEC-PB 300-24C
Technische Daten Technical Data MEC-PB 600-12 MEC-PB 600-24 MEC-PB 600-48 MEC-PB 600-12B MEC-PB 600-24B MEC-PB 1000-12 MEC-PB 1000-12C MEC-PB 1000-24
Technische Daten Technical Data MEC-PB 1000-24C MEC-PB 1000-48C MEC-PB 1500-12 MEC-PB 1500-24 MEC-PB 1500-48 MEC-PB 2000-12C MEC-PB 2000-24C MEC-PB 2000-48C
DC-AC Wechselrichter können überall eingesetzt werden
wo keine 230V Stromversorgung zur Verfügung steht.
Die Geräte werden mit einer DC-Spannung von 12V, 24V
oder 48V gespeist. An der AC-Ausgangsbuchse können
z.B. Computer, Notebooks, Fernseher und Maschinen mit
230V Sinusspannung betrieben werden.
Eingangsspg.
Ausgangsspg.
Ausgangsleistung
Spitzenleistung
Wirkungsgrad
Kurvenform
KFZ-Zulassung
Abm. BxHxT (mm)
Artikel Nr.
Eingangsspg.
Ausgangsspg.
Ausgangsleistung
Spitzenleistung
Wirkungsgrad
Kurvenform
KFZ-Zulassung
Abm. BxHxT (mm)
Artikel Nr.
Eingangsspg.
Ausgangsspg.
Ausgangsleistung
Spitzenleistung
Wirkungsgrad
Kurvenform
KFZ-Zulassung
Abm. BxHxT (mm)
Artikel Nr.
EA-mEc-pb 150vA - 2000vA
dc-Ac sinus-WEchsElrichtEr / dc-Ac purE sinE WAvE invErtEr
DC-Eingangsspannung 12V, 24V und 48V
Ausgangsspannung 230V 50Hz
Ausgangsleistung 150VA bis 2000VA
Ausgangsspannung reiner Sinus
Eingang / Ausgang galvanisch getrennt
Hoher Wirkungsgrad
Unter- und Überspannungsschutz
Übertemperaturschutz, Überlastschutz, kurzschlußfest
Sicherheit EN 60950, EN 60146-2
EMV: EN 55014/1 und EN 55014/2
EA-MEC-PB 300-12
Input voltage
Output voltage
Output power
Output peak pwr.
Efficiency
Waveform
Automotive appr.
Dim. WxHxD (mm)
Article No.
Input voltage
Output voltage
Output power
Output peak pwr.
Efficiency
Waveform
Automotive appr.
Dim. WxHxD (mm)
Article No.
Input voltage
Output voltage
Output power
Output peak pwr.
Efficiency
Waveform
Automotive appr.
Dim. WxHxD (mm)
Article No.
11...16VDC
230VAC ±3%
150VA
300VA
>90%
Sinus / Sine
nein / no
190x120x62
35300128
11...15VDC
230VAC ±3%
600VA
1000VA
>90%
Sinus / Sine
E-Mark
295x180x72
35300110
21...30VDC
230VAC ±3%
1000VA
1500VA
>94%
Sinus / Sine
E-Mark
383x182x88
35300137
11...16VDC
230VAC ±3%
150VA
300VA
>90%
Sinus / Sine
E-Mark
200x132x72
35300132
21...30VDC
230VAC ±3%
600VA
1000VA
>93%
Sinus / Sine
E-Mark
295x180x72
35300111
42...62VDC
230VAC ±3%
1000VA
1500VA
>95%
Sinus / Sine
E-Mark
383x182x88
35300138
20...30VDC
230VAC ±3%
150VA
300VA
>90%
Sinus / Sine
nein / no
190x120x62
35300129
42...60VDC
230VAC ±3%
600VA
1000VA
>94%
Sinus / Sine
E-Mark
295x180x72
35300122
11...16VDC
230VAC ±3%
1500VA
2000VA
>86%
Sinus / Sine
E-Mark
390x275x105
35300123
DC-AC inverters are designed to operate in versatile appli-
cations where no mains supply is available. These models
operate with a 12V, 24V or 48V DC source.
The AC output voltage, with 230V pure sine wave, is avail-
able to power equipment like computers, notebooks, TV
receivers etc., as well as some industrial equipment.
20...30VDC
230VAC ±3%
150VA
300VA
>90%
Sinus / Sine
E-Mark
200x132x72
35300133
10,5...15VDC
230VAC ±3%
600VA
1000VA
>85%
Sinus / Sine
nein / no
335x236x83
35300126
20...32VDC
230VAC ±3%
1500VA
2000VA
>89%
Sinus / Sine
E-Mark
390x275x105
35300124
DC input voltage 12V, 24V and 48V
Output voltage 230V 50Hz
Output power 150VA up to 2000VA
Output voltage pure sine wave
Input / Output galvanic isolated
High efficiency
Under and over voltage protection
Over temperature / load protection, short circuit protected
Safety EN 60950, EN 60146-2
EMI: EN 55014/1 and EN 55014/2
11...16VDC
230VAC ±3%
300VA
500VA
>90%
Sinus / Sine
nein / no
285x120x62
35300130
21...30VDC
230VAC ±3%
600VA
1000VA
>85%
Sinus / Sine
nein / no
335x236x83
35300127
42...62VDC
230VAC ±3%
1500VA
2000VA
>90%
Sinus / Sine
E-Mark
390x275x105
35300125
11...16VDC
230VAC ±3%
300VA
500VA
>90%
Sinus / Sine
E-Mark
237x155x72
35300134
10,5...15VDC
230VAC ±3%
1000VA
1500VA
>85%
Sinus / Sine
nein / no
395x236x83
35300112
10...16VDC
230VAC ±3%
2000VA
2500VA
>91%
Sinus / Sine
E-Mark
422x208x166
35300139
EA-MEC-PB 1000-12
20...30VDC
230VAC ±3%
300VA
500VA
>90%
Sinus / Sine
nein / no
285x120x62
35300131
10,5...15VDC
230VAC ±3%
1000VA
1500VA
>91%
Sinus / Sine
E-Mark
383x182x88
35300136
20...32VDC
230VAC ±3%
2000VA
2500VA
>94%
Sinus / Sine
E-Mark
422x208x166
35300140
20...30VDC
230VAC ±3%
300VA
500VA
>90%
Sinus / Sine
E-Mark
237x155x72
35300135
21...30VDC
230VAC ±3%
1000VA
1500VA
>87%
Sinus / Sine
nein / no
395x236x83
35300113
42...62VDC
230VAC ±3%
2000VA
2500VA
>95%
Sinus / Sine
E-Mark
422x208x166
35300141