JWS50-48/A TDK Corporation, JWS50-48/A Datasheet

no-image

JWS50-48/A

Manufacturer Part Number
JWS50-48/A
Description
Power Supply, Industrial, JWS Series, 52.8 Watt, 48 Volt Output, 1.1 Amp Maximum At 40 Deg F, 0.88 Amp Maximum At 50 Deg F
Manufacturer
TDK Corporation
Datasheet

Specifications of JWS50-48/A

Brand/series
JWS Series
Current, Output
1.1 A (Max.)
Frequency, Operating
63 Hz
Line Regulation
192 mV
Load Regulation
240 mV
Number Of Outputs
1
Special Features
PFC
Standards
UL Listed, CSA Certified, EN60950, VDE Approved, CE Approved, Built to Meet DENTORI
Temperature, Operating
-10 to 50 °C
Voltage, Input
85-265 VAC⁄120-330 VDC
Voltage, Output
48 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J W S F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current (100 / 200VAC)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Remote On / Off
AC Power Fail
Parallel Connection
Operating Temp. (open frame)
Operating Temp. (with cover)
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
*1 non condensing
VDE0160 Approved
5 Year Warranty
Power Factor Corrected
Level B EMI
MODEL
(*1)
(*1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
mA
ms
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI
JWS50
350
-10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600)
-10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150)
No
Specify as Option /R
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
-10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC
JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan
10 - 55Hz (1 minute sweep), 19.6m/s
Single Output Industrial Power Supplies
MAW1202-22
Not Available
Not Available
30 - 90% RH
>100M at 25ºC & 70%RH, Output to Ground 500VDC
14 / 28
JWS75
450
Output to Ground 500VAC (100mA) for 1 min.
EN55011 / EN55022-B, FCC Class B, VCCI-B
85 - 265VAC (47 - 63Hz) or 120 - 330VDC
Benefit
JWS Series
Factory Automation
Test & Measurement
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
No additional Approvals Needed
Lower Cost of Ownership
Supports Global Use
Assists System Compliance
5 Year Warranty
Power factor Corrected
Approved to VDE0160 Machinery Directive
Universal Input (85 - 265VAC)
See side 2
Five Years
JWS100
Meets EN61000-3-2
650
< 196.1 m/s
-30 to +85ºC
10 - 95% RH
<0.02%/ºC
>105%
0.75
Yes
20
MAW1203-22
JWS150
25 / 50
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
850
2
2
constant X, Y, Z 1 hour
Yes
10 - 90% RH
Standard
Standard
Standard
MB1210
JWS300
1900
20 / 40
MB1216
JWS600
3000
39

Related parts for JWS50-48/A

JWS50-48/A Summary of contents

Page 1

... 95% RH JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. >100M at 25ºC & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s < ...

Page 2

... JWS100-28/A 28.0V 25.2 - 30.8 3.6 JWS150-28/A 28.0V 25.2 - 30.8 5.5 JWS300-28 28.0V 25.2 - 33.6 12 JWS600-28 28.0V 25.2 - 33.6 23 JWS50-48/A 48.0V 43.2 - 52.8 1.1 JWS75-48/A 48.0V 43.2 - 52.8 1.6 JWS100-48/A 48.0V 43.2 - 52.8 2.1 JWS150-48/A 48.0V 43.2 - 52.8 3.3 JWS300-48 48.0V 43 ...

Related keywords