S2C-H01 ABB, S2C-H01 Datasheet

no-image

S2C-H01

Manufacturer Part Number
S2C-H01
Description
AUXILIARY CONTACT, 1NC, BOTTOM FITTED
Manufacturer
ABB
Datasheet

Specifications of S2C-H01

Svhc
No SVHC (18-Jun-2010)
Accessory Type
1 N/C
For Use With
MCB S200 Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ABB
System
pro M compact
Auxiliary contact and signal/auxiliary contact
Rated current
Min. rated voltage UBmin
Min. rated operational current/voltage
Short-circuit withstand capacity
Overvoltage category
Surge voltage (1.2/50 ms)
Connection cross section
Tightening torque
Contact stability in vibration test according
to DIN IEC 68-2-6
Mechanical service life
Dimensions (H x D x W)
Bottom-fi tting auxiliary contact
Contact complement
Contact load
Min. rated voltage
Short-circuit withstand capacity
Electrical serviceable life
Standard
Connection cross-section
Tightening torque
Signal auxiliary contact for F 200 125A and F 200 B
Rated current
Min. rated voltage Ub min
Connection cross section
Tightening torque
Dimensions (H x D x W)
Shunt trip for S 200 MCBs
Rated voltage
Max release duration
Min. release voltage
Consumption on release
Coil resistance
Terminals
Tightening torque
Dimensions (H x D x W)
Shunt trip for F 200 RCCBs
Rated voltage
Max release duration
Min. release voltage
Consumption on release
Coil resistance
Terminals
Tightening torque
Dimensions (H x D x W)
®
Technical features
Auxiliary elements and accessories for MCBs S 200
and RCDs F 200 and DS 200 series
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
Ub
Ib max
AC
DC
AC
DC
Ub
Ib max
mm
mm
mm
mm
mm
N*m
mm
mm
mm
mm
Nm
Nm
Nm
Nm
ms
ms
VA
kV
Ω
A
V
V
V
V
A
A
V
V
V
V
V
V
V
A
V
V
V
V
V
2
2
2
2
2
1NO (1 make contact), 1NC (1 normally closed contact), leading make contact, late closing
12 DC 12 AC 24 DC 24 AC 60 DC 60 AC 110 DC
2.2
12 DC
10.6
0.75…2.5 (up to 2 x 1.5 mm
2.5
AC14 2 A/230 V - DC 12 identical DC13/DC13 1 A /50 V, 2 A/30 V
12 AC
85 x 69 x 17.5
5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA
85 x 69 x 17.5
7.8
1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
230 VAC 1000 A, fault protection with S 201-K2 or Z2
4.5
S2C-H6R, S2C-H11L, S2C-H20, S2c-H02 and S2C-S/H6R
F 2C-A1
S 2C-A1
12…60
12…60
12...60
12...60
2x1.5
<10
4.5
5.5
0.2
3.7
2.5
10
10
16
6
7
60 DC
5
348
10 mA at 12 V; 5 mA at 24 V
230 a.c. 100A with S201 K4
automatic reclosing < 10 ms
> 4000 switchover cycles
14
S 2C-H10 and S 2C-H01
12 AC/DC at 0.1 VA
VDE 0106 Part 101
10000 operations
60 AC
2
306
85 x 69 x 8.8
85 x 69 x 8.8
for S2C-H11L, S2C-H20L and S2C-H02L)
F2 125A-S/H
0.75 to 2.5
8.8
1...1.5
230
110
0.5
0.8
10
24
24
III
4
6
1
110 DC
0.35
5.5
110 AC
0.5
110 AC
85 x 69 x 17.5
85 x 69 x 17.5
3.8
110…415
110…250
110...415
110...250
S 2C-A2
F 2C-A2
220 DC
2x1.5
<10
150
225
0.2
1.1
2.5
55
80
16
10
75
55
250 DC
25
230 AC 415 AC
1.0
415 AC
2.7
66.4
4/5
4

Related parts for S2C-H01

S2C-H01 Summary of contents

Page 1

... S2C-H11L, S2C-H20L and S2C-H02L) Nm 1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L) 5g, 20 sweep cycles 5…150… AC/DC automatic reclosing < 10000 operations 8.8 S 2C-H10 and S 2C-H01 1NO (1 make contact), 1NC (1 normally closed contact), leading make contact, late closing ...

Page 2

... CBs and RCBOs). Suitable for MCBs S 200 series, RCCBs F 200 series, RCBOs DS 200 series. Function S2C-H6R: indication of the position of the device’s contacts. Suitable for MCBs S200 series mounted on the left side of the MCBs thanks to the special pin. They are not suitable to be mounted together with RCD-block DDA200 ...

Page 3

... DIN rail used for measuring duties where the neutral conductor must be in the open position. Due to the special design of the handle - when switching ON the MCB – the neutral will make before the MCB is closed. The S2C - Nt is not to switch with a tool (screw driver). Description Max 40A ...