S2C-H6R

Manufacturer Part NumberS2C-H6R
DescriptionAUXILIARY CONTACT, SIDE FITTED
ManufacturerABB
S2C-H6R datasheet
 

Specifications of S2C-H6R

SvhcNo SVHC (18-Jun-2010)Accessory Type1 C/O
For Use WithMCB S200 SeriesLead Free Status / RoHS StatusLead free / RoHS Compliant
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (77Kb)Embed
Next
System
Technical features
pro M compact
Auxiliary elements and accessories for MCBs S 200
®
and RCDs F 200 and DS 200 series
Auxiliary contact and signal/auxiliary contact
Rated current
Min. rated voltage UBmin
AC
DC
Min. rated operational current/voltage
Short-circuit withstand capacity
Overvoltage category
Surge voltage (1.2/50 ms)
Connection cross section
Tightening torque
Contact stability in vibration test according
to DIN IEC 68-2-6
Mechanical service life
Dimensions (H x D x W)
Bottom-fi tting auxiliary contact
Contact complement
Contact load
Min. rated voltage
Short-circuit withstand capacity
Electrical serviceable life
Standard
Connection cross-section
Tightening torque
Signal auxiliary contact for F 200 125A and F 200 B
Rated current
AC
DC
Min. rated voltage Ub min
AC
DC
Connection cross section
Tightening torque
Dimensions (H x D x W)
Shunt trip for S 200 MCBs
Rated voltage
AC
DC
Max release duration
Min. release voltage
AC
DC
Consumption on release
Ub
Ib max
Coil resistance
Terminals
Tightening torque
Dimensions (H x D x W)
Shunt trip for F 200 RCCBs
Rated voltage
AC
DC
Max release duration
Min. release voltage
AC
DC
Consumption on release
Ub
Ib max
Coil resistance
Terminals
Tightening torque
Dimensions (H x D x W)
ABB
S2C-H6R, S2C-H11L, S2C-H20, S2c-H02 and S2C-S/H6R
A
V
V
10 mA at 12 V; 5 mA at 24 V
V
230 a.c. 100A with S201 K4
kV
2
2
mm
0.75…2.5 (up to 2 x 1.5 mm
for S2C-H11L, S2C-H20L and S2C-H02L)
Nm
1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA
automatic reclosing < 10 ms
10000 operations
mm
85 x 69 x 8.8
S 2C-H10 and S 2C-H01
1NO (1 make contact), 1NC (1 normally closed contact), leading make contact, late closing
AC14 2 A/230 V - DC 12 identical DC13/DC13 1 A /50 V, 2 A/30 V
V
12 AC/DC at 0.1 VA
230 VAC 1000 A, fault protection with S 201-K2 or Z2
> 4000 switchover cycles
VDE 0106 Part 101
mm
2
0.75 to 2.5
N*m
F2 125A-S/H
A
A
V
V
2
mm
Nm
mm
85 x 69 x 8.8
S 2C-A1
V
12…60
V
12…60
ms
<10
V
7
V
10
V
12 DC 12 AC 24 DC 24 AC 60 DC 60 AC 110 DC
A
2.2
2.5
4.5
5
14
8.8
Ω
3.7
mm
2
16
Nm
2.5
mm
85 x 69 x 17.5
F 2C-A1
V
12...60
V
12...60
ms
10
V
6
V
4.5
V
12 DC
12 AC
60 DC
60 AC
VA
10.6
7.8
348
306
5.5
mm
2
2x1.5
Nm
0.2
mm
85 x 69 x 17.5
10
24
24
III
4
0.5
6
1
230
110
1...1.5
0.8
S 2C-A2
110…415
110…250
<10
55
80
110 AC
220 DC
230 AC 415 AC
0.35
0.5
1.1
1.0
2.7
225
16
2.5
85 x 69 x 17.5
F 2C-A2
110...415
110...250
10
75
55
110 DC
110 AC
250 DC
415 AC
5.5
3.8
25
66.4
150
2x1.5
0.2
85 x 69 x 17.5
4/5
4

S2C-H6R Summary of contents

  • Page 1

    ... AC DC Max release duration Min. release voltage AC DC Consumption on release Ub Ib max Coil resistance Terminals Tightening torque Dimensions ( ABB S2C-H6R, S2C-H11L, S2C-H20, S2c-H02 and S2C-S/H6R 230 a.c. 100A with S201 0.75…2.5 ( 1.5 mm for S2C-H11L, S2C-H20L and S2C-H02L) Nm 1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L) 5g, 20 sweep cycles 5… ...

  • Page 2

    ... CBs and RCBOs). Suitable for MCBs S 200 series, RCCBs F 200 series, RCBOs DS 200 series. Function S2C-H6R: indication of the position of the device’s contacts. Suitable for MCBs S200 series mounted on the left side of the MCBs thanks to the special pin. They are not suitable to be mounted together with RCD-block DDA200 ...

  • Page 3