QO112M100 SQUARE D, QO112M100 Datasheet

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Catalog
1100CT0501
2007
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page
QO
QO
Homeline
QO
Centers and Enclosures
Class 1100
®
®
, QOM2 and Q-Frame Enclosed Circuit Breakers . . . . . . . . . . . . . . . 34
Circuit Breakers and Load Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
®
®
Circuit Breakers and Load Centers . . . . . . . . . . . . . . . . . . . . . 40
and Homeline
®
Load

Related parts for QO112M100

QO112M100 Summary of contents

Page 1

Catalog 1100CT0501 2007 ® QO and Homeline Centers and Enclosures Class 1100 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 2

QO and Homeline Load Centers and Enclosures Table of Contents 2 © 2007 Schneider Electric All Rights Reserved TABLE OF CONTENTS Product Description 3 Features 3 ® QO Catalog Number Description 4 General information and Application Data 5 ...

Page 3

... Top or bottom feed by rotating convertible mains panels 180 degrees Top or bottom feed for three-phase convertible panels by removing main circuit breaker and rotating panel 180 degrees Combination slot/square drive neutral, ground, and cover screws for positive drive and improved torque Three grounding bar mounting locations for ease of wiring ...

Page 4

QO and Homeline Load Centers and Enclosures Catalog Number Description ® QO Load Centers Number Segment Character Description ® and NOM Listed Load Center Family ® CQO CSA Blank Single Phase 1 3 ...

Page 5

QO Circuit Breaker Load Center QO QO 2-Pole 1-Pole QO-GFI QO-GFI QO-AFI 1-Pole 1-Pole 2-Pole QOK, 1-Pole QO-SWN, 1-Pole 03/2007 ® QO and Homeline GENERAL INFORMATION AND APPLICATION DATA Circuit breaker load centers for use on electrical systems are ...

Page 6

QO and Homeline Load Centers and Enclosures General Information and Application Data QO130M150 Indoor Cover QO140M200RB Bolt-On Hubs 6 © 2007 Schneider Electric All Rights Reserved Indoor Enclosures (Type 1) Welded sheet steel with knockouts at top, bottom, ...

Page 7

Tandem circuit breaker mounts on rails. Branch Circuit Breaker 03/2007 ® ® QO and Homeline Load Centers and Enclosures General Information and Application Data Class CTL Class CTL load centers are UL Listed Circuit breaker mounting rails have slots to ...

Page 8

QO and Homeline Load Centers and Enclosures General Information and Application Data QO24L70S QO816L100DS QO148L125GF 8 © 2007 Schneider Electric All Rights Reserved Single Phase, 2–16 Circuits, 30–125 A, Fixed Mains UL Listed File E-6294 Suitable for use ...

Page 9

Main Circuit Breaker Main Lug Top or bottom mains positioning. Rotate entire load center 180 degrees. 03/2007 ® ® QO and Homeline Load Centers and Enclosures General Information and Application Data Single-Phase, 12–42 Circuits, 100–225 A, Convertible Mains UL Listed ...

Page 10

QO and Homeline Load Centers and Enclosures General Information and Application Data Cover QOL125 Kit QOL225 Kit QOM1 Main Frame Size 50–125 A QOM2 Main Frame Size 100–225 A 10 © 2007 Schneider Electric All Rights Reserved Single-Phase, ...

Page 11

QO2L30TTS QO130M150 QO24L60NRNM QO1816M200FTRB 03/2007 ® ® QO and Homeline Load Centers and Enclosures General Information and Application Data Special Purpose Recreational Vehicle and Manufactured Housing Load Centers UL Listed (File E-6294) and CSA Certified (LL89066-14) Single-phase, 2- and 3-wire ...

Page 12

QO and Homeline Load Centers and Enclosures General Information and Application Data QO48M60DSGP ® QO Intelligent Load Center Wide Gutter 12 © 2007 Schneider Electric All Rights Reserved Generator Panels Generator Panel Manu al Transfer Connects utility and ...

Page 13

... Terminals suitable for one #14 #4 AWG coppe r or one #12 #4 AWG aluminum wire Positioned on both sides of the mains compartment Slot/square drive wire binding screws Three (3) # AWG copper or # AWG aluminum terminations standard circuits, 100 load centers © 2007 Schneider Electric All Rights Reserved ® ...

Page 14

QO and Homeline Load Centers and Enclosures General Information and Application Data QOL3225 Main Lugs Kit QDL Circuit Breaker 70–225 A 14 © 2007 Schneider Electric All Rights Reserved Three-Phase, 3–42 Circuits, 60–225 A, Convertible or Fixed Mains ...

Page 15

QON42MS400 and MH68 QON42LS400 and MH53 03/2007 ® ® QO and Homeline Load Centers and Enclosures General Information and Application Data Single-Phase, 12–42 Circuits, 300–400 A, Fixed Mains UL Listed File E-6294 Suitable for use as service equipment 75 °C ...

Page 16

QO Circuit Breaker Load Centers—Class 1130 General Information and Application Data PG18GTA Grounding Bar Kit PK6FL Flush Lock Kit PK4FL Flush Lock Kit LK150AN LK70AN Auxiliary Neutral Lugs 16 © 2007 Schneider Electric All Rights Reserved Accessories Grounding Bar Kits ...

Page 17

QO2175SB Back-fed Main Circuit Breaker Retaining Kit (PK4MB2LA) QO Manual Transfer Equipment Kit (PK4DTIM4HA) Generator Interlock Kit Installed 03/2007 ® ® QO and Homeline Load Centers and Enclosures General Information and Application Data Accessories (Continued) ® Surgebreaker Secondary Surge Arrester ...

Page 18

... Designed for connecting wireway or other enclosures to units having RB Cat. No. bolt-on conduit provisions. Provides a bushed opening equal to 2 inch conduit. Eliminates the need for conduit nippling. BC200 QO112M100 QO116M100 QO120M100 QO124M100 QO124M125 QO112M100C QO11220M100C QO116M100C QO120M100C Tap Off Wire Lug Type Wire Size Crimp (1) #8 AWG 1 /0 AWG Crimp ...

Page 19

Slot / Robertson screw 0.3125 [8] Cross Section of Size 1 Ground Bar Dimensions: 03/2007 ® QO and Homeline TECHNICAL INFORMATION Grounding Bar Kits All PK equipment grounding kits are supplied with mounting screws, necessary installation instructions, and an Equipment ...

Page 20

... UL Listed for 5000 A rms symmetrical short circuit rating when used in 3-phase, 240 Vac, corner grounded Delta systems, when used as main lugs load center only. Use 240 Vac circuit breakers only. 3 22,000 A rms symmetrical maximum when supplied by integral type QOM-VH main circuit breaker from Square D interrupting rating and when all installed Listed for 5000 A rms symmetrical short circuit rating when used on 3-phase, 240 Vac, corner grounded Delta systems ...

Page 21

... Load Center Rating in Cover Catalog Catalog Number Amps Number Convertible Mains – Factory-Installed Main Circuit Breaker QOM1 Main Frame Size – Convertible to Main Lugs or Lower Amperage Main Circuit Breaker – Copper Bus QO112M100 QOC12UF/S QO116M100 QOC20U100F/S 100 QO120M100 QOC20U100F/S QO124M100 QOC24UF/S ...

Page 22

... UL Listed at 5000 A rms symmetrical short circuit current rating when used in 3-phase, corner grounded, Delta systems, when used as main lugs load center only. Use 240 Vac circuit breakers only. 4 22,000 A rms symmetrical maximum when supplied by integral type QOM-VH main circuit breaker from Square D ® interrupting rating and when all QO installed branch circuit breakers have 10,000 A rms symmetrical minimum interrupting rating ...

Page 23

... Load Center Rating Catalog Cover Catalog in Number Number Amps Convertible Mains – Factory-Installed Main Circuit Breaker QOM1 Main Frame Size – Convertible to Main Lugs or Lower Amperage Main Circuit Breaker – Copper Bus QO112M100RB Included 100 QO116M100RB Included QO120M100RB Included 125 QO124M125RB Included Convertible Mains – ...

Page 24

... QO and Q1 branch circuit breakers have 10,000 A rms symmetrical minimum interrupting rating. 6 25,000 A rms symmetrical maximum when supplied by integral type QDL main circuit breaker from Square D ® when all installed QO and Q1 branch circuit breakers have 10,000 A rms symmetrical minimum interrupting rating. ...

Page 25

... QO130L150TC Included 200 QO13040L200GC Included Convertible Mains – Factory-Installed Main Circuit Breaker – 22,000 RMS Symmetrical Amperes Short Circuit Current Rating QOM1 Main Frame Size – Convertible to Main Lugs – Copper Bus QO112M100C Included QO11220M100C Included 100 QO116M100C Included QO120M100C Included Convertible Mains – ...

Page 26

QO Circuit Breaker Load Centers—Class 1130 Indoor Dimensions W H Box in. mm in. mm in. No. 1 3.81 97 6.72 171 3.00 2 4.81 122 9.30 236 3.19 3 4.81 122 9.30 236 3.19 4 8.88 226 12.57 319 ...

Page 27

OUTDOOR DIMENSIONS AND KNOCKOUTS 2.5 in. (64 mm) Hub Max Box 1NM Box 1R 2.5 in. (64 mm) 2.5 in. (64 mm) Hub Max. Hub Max ...

Page 28

... Por favor lea la informacion antes de instalar. ---- QOM...VH 10,000 / QO, QOT & Q1 001021 Type of circuit breakers Load center accessories. from Square D that may be used in this Neutral lug for 1/0 AWG or larger wire. panelboard. Load Center Accessories - Kits PK4MB2LA Back-fed Main Cir. Brkr. Retaining ...

Page 29

... Please read information before installing. ---- QO...VH 10,000 / QO Por favor lea la informacion antes de instalor. 001021 Type of circuit breakers from Square D that Load center accessories. may be used in this panelboard. Neutral lug for 1/0 AWG or larger wire. Load Center Accessories - Kits PK3MB Back-fed Main Cir. Brkr. Retaining ...

Page 30

QO Circuit Breaker Load Centers—Class 1130 Wiring Diagrams WIRING DIAGRAMS G QO2L30S QO2L30TTS QO2L40RB S/N S/N G QO816L100F/S B QO816L100DF/S QO816L100DFCU/SCU QO816L100TF/S QO816L100RB QO816L100DTF/S QO816L100RBCU QO12436L200TFT QO132L125G S/N S/N QON12LS400 ...

Page 31

... QO124M125RB QO124M150 QO124M200 QO124M100 MAIN QO13842MX150 QO13842UX225 QO13842MX200 QO13842MX225 03/2007 ® QO and Homeline S MAIN MAIN QO112M100 QO116M100 QO112M100RB QO116M100RB QO112M100C QO116M100C S S MAIN N N QO12030M150 QO12030M150RB QO12030M150C S S MAIN N N QO130M150 QO130M200 QO130M150RB QO130M150C QO130M200C QO130M200RB MAIN QO140M200 QO140M225 QO142M200 QO140M200RB ...

Page 32

QO Circuit Breaker Load Centers—Class 1130 Wiring Diagrams S N QO403L60NF/S QO403L60NRB QO324L125G QO327M100 QO327M100RB 32 © 2007 Schneider Electric All Rights Reserved ...

Page 33

QO 03/2007 ® , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 TABLE OF CONTENTS General Information and Application Data 34 Type 34 Service 34 Ratings 34 Enclosure 34 Type 3R Rainproof 34 Circuit Breakers 35 Knockouts 35 Equipment Grounding Bar ...

Page 34

QO , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 General Information and Application Data QO2100BNS QO2100BNRB QOM22225NRB Q22200NS With Cover Removed (Order Q-Frame Circuit Breaker Separately) 34 © 2007 Schneider Electric All Rights Reserved GENERAL INFORMATION AND APPLICATION DATA ...

Page 35

QO QOM2200VH Circuit Breakers Factory-installed equipment grounding bar. PKOGTA2 field installed. 03/2007 ® , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 General Information and Application Data Circuit Breakers ® Visi-Trip indication (QO Lugs suitable for aluminum or copper wire (refer ...

Page 36

QO , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 Technical Information TECHNICAL INFORMATION Enclosed Molded-Case Circuit Breaker Ratings Enclosure Rating in Type 1 Service Amperes Catalog Number Enclosed Circuit Breaker Mounting Base 240 Vac ...

Page 37

QO C,D,E,F A,B,C,D Box 1, 2 E,F,G,H C,D,E,F 2-1/2 in. Hub Max. D,E,F,G A,B D,E,F,G Box 4 Box 4R 03/2007 , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 DIMENSIONS AND KNOCKOUTS Enclosure No. in. 1 5.88 2 5.88 1R 4.56 ...

Page 38

QO , QOM2 and Q-Frame Enclosed Circuit Breakers—Class 1131 Dimensions and Knockouts 38 © 2007 Schneider Electric All Rights Reserved 03/2007 ...

Page 39

Homeline Circuit Breakers and Load Centers—Class 1170 TABLE OF CONTENTS Product Description 40 Features 40 ® Homeline Catalog Number Description 41 General Information and Application Data 42 Type 42 Service 42 Ratings 42 UL Listed 42 Class CTL ...

Page 40

... Single captive screw interior mounting on indoor panels to ease removal Split branch neutral for clutter-free wiring Top or bottom feed by rotating convertible mains panels 180 degrees Combination slot/square drive neutral, ground, and cover screws for positive drive and improved torque Three ground bar mounting locations for ease of wiring ...

Page 41

Homeline Load Centers Number Segment Character Description Load Center Family HOM UL Listed Spaces / Circuits 3040 M Main circuit breaker Mains Type L Main lugs U Universal mains Amps G Factory included Ground Bar T Factory-installed Blank Purchase ...

Page 42

Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data HOM24M125C HOM 1-Pole HOM 2-Pole 1 space required. 2 spaces required. HOMT 1-Pole Tandem HOMT Quad Circuit Breaker 1 space required. 2 spaces required. HOM 1-Pole GFI ...

Page 43

HOM40M200C With Cover New RB Device Bolt-On Hubs 03/2007 ® Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data Indoor Enclosures (NEMA Type 1) Welded sheet steel with knockouts at top, bottom, back and sides Finish: gray ...

Page 44

Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data HOM612L100F Flush Cover Combination Cover with Door 44 © 2007 Schneider Electric All Rights Reserved Single-Phase, 2–12 Circuits, 70–125 A, Fixed Mains UL Listed File E-6294 Suitable ...

Page 45

HOM816M200FTRB HOM816U200FTRB HOM3040U200TC 03/2007 ® Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data Single-Phase, 12–42 Circuit, 100–225 A, Convertible Mains, Continued Cover Combination flush and surface cover included with load centers Optional door lock kit for ...

Page 46

Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data RB Hub BC200 Enclosure Coupling ® HOM Surgebreaker Surge Arrester 2 spaces required. PK15GTA LK100AN HOMFP QOM1FP QOM2FP 46 © 2007 Schneider Electric All Rights Reserved Accessories ...

Page 47

Back-Fed Main Circuit Breaker Retaining Kit Cutaway Showing Installed Generator Interlock Kit PK6FL QOL125 QOL225 03/2007 ® Homeline Circuit Breakers and Load Centers—Class 1170 General Information and Application Data Back-Fed Main Circuit Breaker Retaining Kits HOM1RK: secures circuit breaker to ...

Page 48

Homeline Circuit Breakers and Load Centers—Class 1170 Technical Information Slot / Robertson screw 0.3125 [8] Dimensions: Cross Section of Size 1 Ground Bar 48 © 2007 Schneider Electric All Rights Reserved TECHNICAL INFORMATION Grounding Bar Kits All PK equipment ...

Page 49

MAIN LUGS AND MAIN CIRCUIT BREAKERS RATINGS Single-Phase, Three-Wire, 120/240 Vac Main Lugs Mains Load Center Rating Load Center Cover in Catalog Number Catalog Amps Number Fixed Mains – Factory-Installed Main Lugs 70 HOM24L70F/S Included 100 HOM612L100F/S Included 125 HOM48L125GC ...

Page 50

Homeline Circuit Breakers and Load Centers—Class 1170 Main Lugs and Main Circuit Breakers Ratings Single-Phase, Three-Wire, 120/240 Vac Main Circuit Breaker Mains Load Load Rating Center Cover Center Catalog in Catalog Number Amps Number Convertible Mains – Factory-Installed Main ...

Page 51

Single-Phase, Three-Wire, 120/240 Vac Main Lugs Mains Load Rating Center Cover Center Catalog in Catalog Number Amps Number Fixed Mains – Factory-Installed Main Lugs 70 HOM24L70RB Included 100 HOM612L100RB Included 125 HOM48L125GRB Included Convertible Mains – Factory-Installed Main Lugs – ...

Page 52

... Circuit Breakers and Load Centers—Class 1170 Homeline Label Samples HOMELINE LABEL SAMPLES For information on two-tier and three-tier series ratings, see Data Bulletin number 4100DB0301, Square D Circuit Current Ratings , located on the Technical Library at www.SquareD.com. Homeline Box Label Sample Number of circuits maximum. ...

Page 53

WIRING DIAGRAMS S N HOM24L70F/S HOM48L125GC HOM24L70RB HOM48L125GRB HOM816L125TC HOM12L125C HOM12L125RB HOM12L200RB HOM20L125C HOM2024L125TC HOM20L125RB HOM2040L200RB HOM2040L200TC ...

Page 54

Homeline Circuit Breakers and Load Centers—Class 1170 Wiring Diagrams S S MAIN HOM816M100C HOM816M100TC HOM816M100RB MAIN MAIN HOM1224M100TC HOM1224M125C HOM1224M125TC HOM1224M200TC MAIN ...

Page 55

I NDEX A accessories cover filler plates 16, 46 flush lock kits 16, 47 generator circuit breaker interlock kit 17, 47 grounding bar kits 16, 19, 51 manual transfer equipment kit 17 secondary surge arrester 17, 46 assemblies ...

Page 56

QO and Homeline Circuit Breaker Load Centers and Enclosures Catalog Schneider Electric USA 1601 Mercer Road Lexington, KY 40511 USA 1-888-SquareD (1-888-778-2733) www.us.SquareD.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility ...