CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
03/2007
Generator Interlock Kit Installed
Back-fed Main Circuit Breaker
Equipment Kit (PK4DTIM4HA)
Retaining Kit (PK4MB2LA)
QO Manual Transfer
QO2175SB
Accessories (Continued)
Surgebreaker
Back-Fed Main Circuit Breaker Retaining Kits
Back-fed main circuit breaker retaining kits secure 2-pole, 10 125 A circuit
breakers to single-phase or three-phase mains interiors when used as
back-fed main circuit breakers. Mounting of retaining kits is based on
top-feed applications.
UL Listed Manual Transfer Equipment Kits
Manual transfer equipment kits secure two 2-pole, 10 125 A circuit breakers.
Generator Circuit Breaker Interlock Kit
Catalog No. Description
PK2MB
PK3MB
PK4MB2LA
PK4MB2HA
Catalog No.
QO2DTI
QO2DTIM
PK4DTIM4LA
PK4DTIM4HA
PK4DTIM4LAL
Catalog No. Description
QOCRBGK1
QOCGK2
QORBGK2
QO
QO2175SB UL Listed secondary surge arrester
Easy plug-on installation for QO
LED indicates operational status
Plug-on design requires two pole spaces
Designed to protect electrical service and major household appliances ,
excluding electronic devices
®
and Homeline
®
QO 6 1 2, 4 8, and 8 16 loa d centers
Three-phase load centers
Mounts on the right side of QO single-phase, 100 125 A convertible main load
center, series S01 and S02. Retains one 2-pole QO circuit breaker with or
without electrical accessories.
Mounts on the right side of QO single-phase, 150 225 A convertible main load
center, series S01 and S02. Retains one 2-pole QO circuit breaker with or
without electrical accessories.
NEMA Type 3R load centers. Interlocks a QOM1, 2-pole main circuit breaker
of a load center (100-125 A) with a QO, 2-pole (15-125 A) branch circuit
breaker. Includes a retaining kit.
For use on G and S Series NEMA Type 1 and G and S1 Series NEMA
Type 3R load centers. Interlocks a QOM2, 2-pole main circuit breaker of a
load center (150 22 5 A) with a QO 2-pole (15 12 5 A) branch circuit breaker.
Includes a retaining kit.
For use on S2 Series NEMA Type 3R load centers. Interlocks a QOM2 2-pole
main circuit breaker of a load center (150 225 A) with a QO 2-pole (15 1 25 A)
branch circuit breaker. Includes a retaining kit.
Description
For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO
and Q1 circuit breakers mounted side-by-side so that only one circuit breaker
can be ON at a time.
QO2DTI mechanical interlock attachment with retaining kits for securing two
adjacent back-fed circuit breakers in dual power supply applications. Can be
used with two 2-pole or one 2-pole and one 1-pole QO circuit breakers in
QO816L100 load centers.
Mounts on the right side of QO single-phase, 100 125 A convertible main load
center, series S01 and S02. Retains two 2-pole QO circuit breakers with a
QO2DTI kit included for dual power supply applications.
Mounts on the right side of QO single-phase, 150 225 A convertible main load
center, series S01 and S02. Retains two 2-pole QO circuit breakers with a
QO2DTI kit included for dual power supply applications.
Mounts on the left side of QO single-phase, 100 1 25 A convertible main load
center, series S01 and S02. Retains two 2-pole QO circuit breakers with a
QO2DTI kit included for dual power supply applications.
For use on "G" and "S" Series NEMA Type 1 and "G", "S1" and "S2" Series
Secondary Surge Arrester
General Information and Application Data
© 2007 Schneider Electric All Rights Reserved
®
Load Centers and Enclosures
®
load centers
17