QO112M100 SQUARE D, QO112M100 Datasheet - Page 18

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
QO
General Information and Application Data
18
© 2007 Schneider Electric All Rights Reserved
Circuit Breaker Load Centers—Class 1130
Mechanical Lugs
Tap Kit with
BC200 Enclosure Coupling
With Tap Kits Installed
RB Hub
SDAG26
Crimp Lugs
Tap Kit for
Accessories (Continued)
Auxiliary Gutters and Tap Kits
Auxiliary Gutter (SDAG26) to Load Center Catalog Number Reference
Tap Kits
Bolt-On Hubs
Equipment with an RB suffix, meaning Rainproof Type 3R construction,
uses the bolt-on hubs listed below. RB devices will accept 0.75 in. (19 mm)
through 2.50 in. (64 mm) bolt-on hubs without the use of reducers. Off-
center conduit thread openings and elongated mounting holes provide quick
and easy adjustment to eliminate costly conduit offsets and bends. Hubs are
suitable for use with conduit having ANSI standard taper pipe thread.
UL Listed Bolt-On Hubs for RB Devices
UL Listed Enclosure Coupling for RB Devices
UL Listed for Use with Auxiliary Gutter SDAG26
SDGT30020
SDGT300300
SDGT300C10C
SDGT300C300C
QOGL20
(grounding lugs)
QO
QO
NOTE: Closing cap (catalog number B-CAP) is provided factory-installed on each device having the RB suffix.
Conduit Size
Hub Cat. No.
Catalog Number
Auxiliary Gutter
UL Listed for Use with Standard Load Centers for Riser Applications
Cat. No.
®
®
Field-installable on the left or right side of load centers
Auxiliary gutters are 13.50 in. wide x 26.12 in. height x 3.75 in. deep
Conduit riser sizes: 1-3/4, 2, 2-1/2 or 3 in. (3 in. requires use of B300
bolt-on hubs)
Flush cover included with auxiliary gutter
Tap kits required for each riser wire to be tapped (see below for tap kits)
Wire range on tap kits is #4 AWG to 300 kcmil copper or aluminum
Tap kits include mechanical-type lugs or studs for crimp-type lugs
Crimp-type lugs not included in tap kits (order separately)
BC200
Single-Phase
Three-Phase
SDAG26
Designed for connecting wireway or other enclosures to units having RB
bolt-on conduit provisions. Provides a bushed opening equal to 2 inch conduit.
Eliminates the need for conduit nippling.
0.75 in.
Mechanical
Mechanical
Mechanical
19 mm
Lug Type
B075
Flush
Crimp
Crimp
Riser Wire
QO112L125G
QO11224L125G
QO112L125GC
QO11224L125GC
QO116L125G
QO11624L125G
QO120L125G
QO12024L125G
QO124L125G
QO120L125GC
QO312L125G
QO320L125G
QO324L125G
1.00 in.
25 mm
B100
(2) #6 AWG 3 00 kcmil Mechanical (1) #6 AWG 2 /0 AWG
(2) #6 AWG 3 00 kcmil Mechanical (1) #6 AWG 30 0 kcmil
(2) #4 AWG 3 00 kcmil
(2) #4 AWG 3 00 kcmil
(2) #6 AWG 2/0 AWG
No
Wire Size
1.25 in.
32 mm
N/A
B125
See Tap
Kit
1.50 in.
38 mm
Lug Type
B150
Crimp
Crimp
QO112M100
QO116M100
QO120M100
QO124M100
QO124M125
QO112M100C
QO11220M100C
QO116M100C
QO120M100C
Tap Off Wire
(1) #4 AWG 30 0 kcmil
(1) #8 AWG 1 /0 AWG
2.00 in.
51 mm
B200
Wire Size
2.50 in.
64 mm
B250
03/2007
No