QO112M100 SQUARE D, QO112M100 Datasheet - Page 28

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
QO
QO Single-Phase Labels
QO SINGLE-PHASE LABELS
The labels below represent typical labels. Information may not be applicable or may change without notice. See the actual label in
28
the load center for the latest information.
QO Single-Phase Box Label Sample
QO Single-Phase Wiring Diagram Sample
Use of unused neutral branch terminal for
equipment grounding, service equipment
Call an electrical contractor or electrician.
* Suitable for use as service equipment when
service disconnect (main breaker) is installed.
* Suitable for use as service equipment when
not more than six main disconnecting means
are provided and when not used as a lighting
and appliance branch circuit panelboard.
See Article 384-14 of the NEC.
* When used as service equipment, all unused
neutral terminals may be used for terminating
equipment ground wires.
See Panelboard interior for Catalog No.
Suitable for use with 75
Catalog number of covers; flush
For installation, repairs or alterations,
See panelboard interior for the
Box Cat. No. / Caja No. de Catalogo:
24 circuit max. / 24 circuitos maximo.
© 2007 Schneider Electric All Rights Reserved
Number of circuits maximum.
Utilice la Cubierta No. de Catalogo:
Enclosure catalog number.
main conductors. See
Lina principal de 125A maximo.
See main or service disconnect
Copper or Aluminum
branch wire ratings.
240 V ~ Max. 1Ø, 50 / 60 Hz.
branch breakers for
QO ® LOAD CENTER
Service Equipment marking.
Circuit Breaker Load Centers—Class 1130
QOC16US or/or QOC16UF
Amperage rating.
Use Cover Cat. No. /
Voltage ratings.
catalog number.
Mains 125A max.
rating if installed.
Type 1 Enclosure
Gabinete Tipo 1
application only.
or surface.
BX18C
o
C
Wire Range (AWG)
Main Breaker
10-14 CU, 10-12 AL
Line Neutral
Wire range for lug torque data table.
Main Lug
Alternate
1/0 - 3 CU / AL
Two 14 or 12 CU, Two 12 AL
Lug
4 CU / AL
6 CU / AL
8 CU / AL
Branch Neutral and Equipment Ground Bar
See circuit breakers and field installed
N
Alternate wiring diagram for main circuit breaker or
N
N
units for wire binding screw torque
Equipment Ground Combinations
Two 10 AL
Installation of back-fed main circuit breaker and
Wire Range (AWG/kcmil)
Main Breaker diagram
LUG TORQUE DATA
O
Line / Linea
4 - 2/0 CU/AL
6 - 2/0 CU/AL
1
See Main
Large 50
Large 45
Large 45
Large 40
Large 35
Breaker
Bar with 2 screw sizes
Torque (in./lbs.)
O
1.
cuando fuese necesario.
2.
automatico principal tipo: QOM1 o QOM1A.
Box bonding when required. / Conexion a la caja
Main breaker type: QOM1 or QOM1A. / Interruptor
2
N
required kit.
Small
Small
Small 25
Small 10
Small 10
35
35
main lug.
3
N
Torque (in/lbs.)
Main Lugs diagram
See Main
10
Breaker
O O
50
50
Bar with 1
screw size
35
35
25
20
25
25
4
** 240 v ~ 3Ph. 3W. Grounded B” phase requires 240 V ~ branch
breakers.
* The rating is equal to the lowest interrupting rating of any circuit breaker
installed. Refer to branch breaker for individual ratings. Additional or
replacement branch circuit breakers, main breaker, or service disconnect
MUST have an interrupting rating equal to or greater than that of the
circuit breaker with the lowest interrupting rating presently installed.
See panelboard interior for breaker types.
100,000
42,0000
*65,000
*42,000
*22,000
*10,000
**5,000
22,000
65,000
22,000
Rating
Panel
3.
4.
Tierra de acometida
RMS Symmetrical Amperes at 120 / 240 V ~ Maximum
QOL125. / No. de
Main lugs kit no:
Short circuit ratings and additional of
Service ground
when required. /
accesorio de las
cuando fuese
--100-200A,300V T Fuse
principales:
Q2...H, KD, QO...VH
replacement circuit breakers.
necesario
QOL125.
zapatas
SHORT CIRCUIT RATING
Remote
QOH
Main
Short circuit ratings.
KG
----
----
----
----
----
----
Type of circuit breakers
single pole. One two pole
requires two spaces.
Torque Note: When main
breaker or main lug
connector mounting nuts
are loosened or removed,
retighten to 75 lbs./in.
torque.
Two single poles. One plug
on space or may use one
from Square D that
may be used in this
Equipment Grounding
panelboard.
QOM...VH
Integral
Main
Lugs
Lugs
Lugs
Lugs
Lugs
Lugs
Lugs
Lugs
Lugs
Terminals
10,000 / OO, QOT & Q1
10,000 / QO, QOT & Q1
5,000 / QO...H (2 pole)
10,000 / QO & QOT
10,000 / QO & QOT
10,000 / QO & QOT
10,000 / QO & QOT
22,000 / OQ.VH
Branch (min.)/
42,000 / QOH
65,000 / QH
Cat. prefix
PK4MB2LA
QO2175SB
SDSA1175
QOSAMK
QOL2125
PK9--27GTA(L)
PKGTAB
LK70AN
LK100AN
QOL125
PK6FL
Neutral lug for 1/0 AWG or larger wire.
Made in U.S.A.
Torque Note: When interior mounting screw is
loosened or removed, retighten to 35 lbs./in.
Install loose label with Spanish translation
on back of cover.
Adhiera la etiqueta suelta con las traducciones
en espanol en la parte posterior del frente.
Please read information before installing
Por favor lea la informacion antes de instalar.
Load center accessories.
001021
Load Center Accessories - Kits
®
* May plug on two adjacent spaces.
~
Back-fed Main Cir. Brkr. Retaining
Plug-0n Surge Arrestor *
1 Phase Surge Arrestor
SDSA1175 Mounting Bracket
1 Phase Plug-on Subfeed Lugs *
Equipment Ground Bar
Equipment Ground Bar Insulator
70A Max. Neutral Lug
125A Max. Neutral Lug
Main Lugs
Indoor Cover Lock
15
UL Listing.
Laboratories, Inc.®
Underwriter’s
15
Issue No. V-2813
Cabinet Box
/
Electric
LISTED
40265-668-02
40265-381-03
03/2007

Related parts for QO112M100