DIN rail mount pluggable miniature thermal circuit breakers are used for protection of power distribution systems,
automation systems, and process control applications. These wide variety of circuit breakers have unique characteristics that tailor
to the needs and performance of many different applications.
The WAGO circuit breaker terminal block uses CAGE CLAMP ® connection technology that reduces wiring time and provides a
connection that is corrosion-resistant, temperature cycling resistant and maintenance-free. An excellent alternative to traditional fusing
methods.
DIN Rail Mount Pluggable Thermal Circuit Breakers
Description
Thermal circuit breaker, plug-in type, on-off switch,
switching duty rated
0.10 A
0.25 A
0.5 A
1.0 A
2.0 A
3.0 A
4.0 A
5.0 A
6.0 A
7.0 A
8.0 A
10.0 A
Thermal circuit breaker, plug-in type, push button reset
0.10 A
0.25 A
0.5 A
1.0 A
2.0 A
3.0 A
4.0 A
5.0 A
6.0 A
7.0 A
8.0 A
10.0 A
Conductor Range:
Electrical Specs:
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AWG 24 - 10 AWG
(stranded and solid)
600 V maximum*
25/30 A maximum*
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
DC 65 V
Technical Data
Voltage rating:
Current ratings:
Typical life:
Ambient temperature:
Insulation co-ordination:
(IEC 60664 and 60664A)
Insulation resistance:
Item
No.
Terminal Block Width:
Strip Length: l
*Current / Voltage limited to circuit breaker
specifications. Consult factory for other ratings.
51012494
51012495
51012496
51012497
51012498
51012499
51012500
51012501
51014523
51012502
51012503
51014625
51011135
51011136
51011137
51011138
51011139
51011140
51017673
51011141
51014524
51011142
51011143
Rated impulse
500 operations at 2 x I
-20...+60°C (T 60) -4...+140°F
withstand voltage
2.5 kV
reinforced insulation in
operating area
Pack.-unit
1
1
1
1
1
1
1
1
1
1
1
pcs
1
1
1
1
1
1
1
1
1
1
1
1
AC 250 V; DC 65 V
0.1...10 A
3,000 operations at 1 x I
>100 MΩ (DC 500 V)
(low-resistive)
(inductive)
8 mm / 0.315 in
12 - 13 mm / 0.49 in
N
Pollution
degree
2
N
Interrupting capacity:
(UL 1077)
Vibration:
Shock:
Corrosion:
Humidity:
Typical time/current characteristics
at +23°C/+73.4° F
5 g (57-500 Hz) ±0.38 mm (10-57Hz)
96 hours at 5% salt mist,
AC 250 V: 2,000 A
DC 65 V: 200 A
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
to IEC 60068-2-27, test Ea
to IEC 60068-2-11, test Ka
to IEC 60068-2-3, test Ca
25 g (11 ms)
240 hours at 95% RH