HDL36150 SQUARE D, HDL36150 Datasheet

CIRCUIT BREAKER, THERMAL MAG, 3P, 150A

HDL36150

Manufacturer Part Number
HDL36150
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 150A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL36150

Actuator Style
Toggle
No. Of Poles
3
Current Rating
150A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PowerPact
Circuit Breakers
Catalog
0611CT0401R06/10
2010
Class 0611
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5
Mounting and Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 34
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 45
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 47
Trip Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 59
MCP Instantaneous Trip Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 74
®
H- and J-Frame

Related parts for HDL36150

HDL36150 Summary of contents

Page 1

PowerPact Circuit Breakers Catalog 0611CT0401R06/10 2010 Class 0611 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 2

...

Page 3

SECTION 1: GENERAL INFORMATION Introduction ......................................................................................................................................5 Features and Benefits ......................................................................................................................5 Common Design Envelope ........................................................................................................5 High Ampere Interrupting Ratings (AIR) ....................................................................................5 Dual-Break Rotating Contacts ....................................................................................................6 Reduced Let-Through Currents .................................................................................................6 Internal Operating Mechanism .........................................................................................................6 Handle Position Indication ..........................................................................................................6 Flexible Configurations ....................................................................................................................7 Field ...

Page 4

PowerPact H- and J-Frame Circuit Breakers Table of Contents ® I-Line Circuit breakers ................................................................................................................. 31 Plug-In and Drawout Circuit Breakers ........................................................................................... 32 Plug-In Circuit Breaker Mounting ............................................................................................. 32 Parts of a Plug-In Configuration ............................................................................................... 32 Drawout Circuit Breaker Mounting ...

Page 5

Section 1—General Information Introduction H-frame and J-frame molded case circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. All circuit breakers are designed to open and close a circuit by nonautomatic means and ...

Page 6

PowerPact H- and J-Frame Circuit Breakers Section 1—General Information Dual-Break Rotating Contacts All PowerPact that reduce the amount of peak current during a short circuit fault. This reduces the let-through currents and enhances equipment protection. Reduced Let-Through Currents The ...

Page 7

Flexible Configurations The PowerPact H- and J-frame circuit breakers may be configured with lugs, bus bar connections, rear connections, I-Line Field Installable Accessories and Trip Units Figure 2: Field Installable Accessories and Trip Units © 2004–2010 Schneider Electric All Rights ...

Page 8

... Catalog Numbering – Poles Frame H-Frame J-Frame Terminations Brand L Lugs Line/Load Side _ Square D M Lugs Line Side N Schneider P Lugs Load Side Electric F Bus Bar A I-Line S Rear Connected N Plug-in D Drawout K Reverse I-Line Interruption Rating (kA) (See Table 1) Table 1: Interrupting Rating UL/CSA/NOM 240 Vac ...

Page 9

... H-Frame Trip Unit Short Circuit Protection (Fixed) I 15–30 A 35–50 A 350 400 750 850 ® H- and J-Frame Circuit Breakers Section 1—General Information ® ), circuit breakers may only be applied 150–250 A J-Frame Amperage Cat. No. 150 A JT3150 175 A JT3175 200 A JT3200 225 A ...

Page 10

... J-Frame Trip Unit Short Circuit Protection (Adjustable 150 A 175 A 750 875 1500 1750 Codes and Standards (Domestic) H- and J-Frame Switches 3 UL 489 IEC Standard 60947 CSA 22.2 No. 5-02 ...

Page 11

Suitable for Isolation (Positive Contact Indication) All PowerPact H-frame and J-frame circuit breakers and switches are suitable for isolation as defined in the IEC 60947-2 standard. • The isolation position corresponds to the O (OFF position) • The operating handle ...

Page 12

PowerPact H- and J-Frame Circuit Breakers Section 1—General Information Marine Ratings UL Marine Listed Circuit Breakers (UL489SA) A standard for molded case circuit breakers which are intended to be installed and used aboard a boat or vessel is included ...

Page 13

Now UL Listed as Current Limiting The current limiting attributes of PowerPact H- and J-frame circuit breakers provide greater protection for downstream devices by limiting the let-throught current in the event of a fault. The current-limiting capabilities of HJ/HL and ...

Page 14

PowerPact H- and J-Frame Circuit Breakers Section 1—General Information Circuit Breaker Endurance Table 13: Frame 150 A H-Frame 250 A J-Frame Corner Grounded Delta Ratings (1Ø-3Ø) Circuit breakers suitable for corner-grounded circuits are marked 1Ø-3Ø. For additional information, refer ...

Page 15

... A 900 A 1700 A HDL36110 HDL36110C HGL36110 125 A 900 A 1700 A HDL36125 HDL36125C HGL36125 150 A 900 A 1700 A HDL36150 HDL36150C HGL36150 1 HD and HG circuit breakers are true 2-pole construction. © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact G J 80% 100% 80% 100% Rated Rated ...

Page 16

PowerPact H- and J-Frame Circuit Breakers Section 1—General Information Table 16: PowerPact J-Frame 250 A Unit-Mount Thermal-Magnetic Current Limiting Circuit Breakers with Factory Sealed Trip Unit (Suitable for Reverse Connection) Interrupting Rating Fixed AC Current Magnetic Trip D Rating ...

Page 17

I-Line Circuit Breaker Catalog Numbers Table 17: Current Rating @ 40 C H-Frame, 150 A, 2P, 600 Vac 50/60Hz, 250 Vdc ...

Page 18

... HDL36060T HGL36060T 1450 A HDL36070T HGL36070T 1450 A HDL36080T HGL36080T 1450 A HDL36090T HGL36090T 1700 A HDL36100T HGL36100T 1700 A HDL36110T HGL36110T 1700 A HDL36125T HGL36125T 1700 A HDL36150T HGL36150T Terminal Wire Range 80% Rated 80% Rated JJA36150( ) JLA36150( ) AL175JD 4-4/0 AWG JJA36175( ) JLA36175 JJA36200( ) JLA36200( ) AL250JD JJA36225( ) JLA36225( ) 3/0 AWG-350 ...

Page 19

Table 20: Adjustable AC Ampere Magnetic Trip Rating Low 150 A 750 A 175 A 875 A 200 A 1000 A 225 A 1125 A 250 A 1250 A 1 Circuit breakers will be labeled with Line and Load markings ...

Page 20

... Electronic Motor Circuit Protectors (AC Only) PowerPact H- and J-frame Electronic Motor Circuit Protectors (MCP) are instantaneous-trip circuit breakers. They are designed to offer short circuit protection and are National Electrical Code compliant when installed as part of a combination controller having motor overload protection. MCP circuit breakers accept the same accessories and terminals as the equivalent thermal-magnetic circuit breakers ...

Page 21

Full Load Amp Settings 1. Determine the motor’s full-load current by referring to the nameplate on the motor. 2. Set the trip range by turning the FLA dial to the setting closest to the motor’s full load current. Automatic ...

Page 22

... The PowerPact MCP helps achieve the high UL508A Short Circuit Current Rating (SCCR) needed to meet NEC Article 409 requirements for industrial control panels. They deliver up to 100 kA at 480 Vac SCCR when used in combination with approved Square D IEC motor starters. Table 25: ...

Page 23

Table 26: MCP Selection by HP Ratings of Induction-Type Squirrel-Cage and Wound-Rotor Motors Horsepower Rating of Induction-Type Squirrel-Cage and Wound-Rotor Motors 3Ø NEC Full Load Starter Size 200 Vac 230 Vac 1/2 1/2 00 3/4 3/4 1 ...

Page 24

PowerPact H- and J-Frame Circuit Breakers Section 1—General Information Automatic Molded Case Switches H-frame and J-frame circuit breakers are also available in automatic molded case switch construction. Automatic switches are similar in construction to circuit breakers, except that the ...

Page 25

Table 29: 2-pole Ampere Rating Cat. No. G Interrupting 150 A HGA26000S15( ) 175 A JGA26000S17( ) 250 A JGA26000S25 Interrupting 150 A HLA26000S15( ) 175 A HLA26000S17( ) 250 A JLA26000S25 The withstand rating is ...

Page 26

PowerPact H- and J-Frame Circuit Breakers Section 2—Mounting and Connections Section 2—Mounting and Connections Table 30: Circuit Breaker Construction Connections H-Frame J-Frame 1 Including rail, backplate, and flush mounting Unit-Mount Circuit Breakers The standard lugs can be removed for ...

Page 27

Mechanical Lugs Unit-mount H-frame and J-frame circuit breakers can be ordered with mechanical line and load side lugs. The standard lugs can be removed for the installation of compression-type lugs or bus connections. All lugs are UL Listed for their ...

Page 28

PowerPact H- and J-Frame Circuit Breakers Section 2—Mounting and Connections Bus-Bar Connections Both H-frame and J-frame circuit breakers may be equipped with captive nuts and screws for direct connection to bars. Terminal nut inserts are needed for replacement of ...

Page 29

Power Distribution Connectors The power distribution connectors (PDC) can be used for multiple load wire connections on one circuit breaker. Use in place of standard distribution blocks to save space and time. Field installable kit includes tin-plated aluminum lug, connectors, ...

Page 30

PowerPact H- and J-Frame Circuit Breakers Section 2—Mounting and Connections Compression Lugs Both copper and aluminum compression lug kits are available for the H-frame and J-frame circuit breakers. Each kit contains required insulators and all mounting hardware. Table 36: ...

Page 31

Rear Connections Rear connections are easily installed on the circuit breaker terminals. The same connection may be installed flat, vertical 45° angle with all combinations possible. The circuit breaker is mounted on a backplate. Figure 7: Horizontal ...

Page 32

PowerPact H- and J-Frame Circuit Breakers Section 2—Mounting and Connections Plug-In and Drawout Circuit Breakers H- and J-frame circuit breakers are available in a plug-in and drawout construction. Plug-In Circuit Breaker Mounting The plug-in base is mounted through a ...

Page 33

Drawout Circuit Breaker Mounting The drawout-mounted chassis is Listed under UL file E113555 and Certified under CSA file LR69561. The chassis is made up of two side plates installed on the base and two other plates mounted on the circuit ...

Page 34

PowerPact H- and J-Frame Circuit Breakers Section 3—Accessories Section 3—Accessories Internal Accessories Field-installable accessories provide flexibility for installation at point of use. Auxiliary switches and the shunt trip or undervoltage release are easy to install, reliable and common to ...

Page 35

Auxiliary and Alarm Switches Auxiliary switches provide remote information of the circuit breaker status and can thus be used for indications, electrical locking, relays, etc. Applications OF/SD Switch Installation & Connection SDE Standards Table 44: Characteristic Supplied as Standard (Form ...

Page 36

PowerPact H- and J-Frame Circuit Breakers Section 3—Accessories Shunt Trip (MX) and Undervoltage Trip (MN) Switches A voltage release can be used to trip the circuit breaker via a control signal. Applications Installation and Connection Operation Table 46: Description ...

Page 37

Add-On Ground-Fault Module (GFM) The Micrologic equipment from damage caused by ground faults add-on module which, when connected to a PowerPact H- or J-frame circuit breaker, provides ground-fault sensing and ground-fault relay functions. HD/JD ground-fault modules feature: ...

Page 38

PowerPact H- and J-Frame Circuit Breakers Section 3—Accessories Earth Leakage Module (ELM) for PowerPact H- and J-Frame MCCBs The Earth Leakage Module (ELM add-on module which, when connected to a PowerPact H- or J-frame MCCB, provides low-level ...

Page 39

Motor Operator The motor operator remotely operates the circuit breaker featuring easy and sure operation: • All circuit breaker indications and information remain visible and accessible, including trip unit settings and circuit breaker connection • Suitability for isolation is maintained ...

Page 40

PowerPact H- and J-Frame Circuit Breakers Section 3—Accessories Rotary Operating Handles Directly-Mounted Rotary Operating Handles Installation Operation Directly Mounted Rotary Operating Handle Models Variations Standards IEC-Style Door-Mounted Rotary Operating Handle Installation Operation Door Mounted Rotary Operating Handle Shaft Length ...

Page 41

Class 9421 NEMA Door Mounted Rotary Operating Handles Installation Operation Shaft Length Table 53: Description Standard Shaft Kit Long Shaft Kit Table 54: Description Standard Handle Assembly Operating Mechanism Standard Shaft Long Shaft Class 9422 Cable Operating Handle Flange-mounted handle ...

Page 42

... Operating mechanism 9422RQ1 (does not include handle mechanism). Circuit Breaker Enclosures and Enclosure Accessories • Square D circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service entrance equipment, except as footnoted. • The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. • ...

Page 43

Table 58: Cat. No. Series HD100S J250F J250S J250R J250DS J250AWK Table 59: Circuit Breaker Cat. No. Prefix HDL,HGL,HJL,HLL HDL,HGL,HJL,HLL JDL,JGL,JJL,JLL Table 60: Circuit Breaker Cat. No. Prefix HDL,HGL,HJL,HLL, JDL,JGL,JJL,JLL Locking Systems Padlocking systems can receive up to three padlocks ...

Page 44

PowerPact H- and J-Frame Circuit Breakers Section 3—Accessories Interlocking Systems Interlocking of Circuit Breakers With Toggle Control The toggle interlock system can receive one or two padlocks with diameters of 0.19–0.31 in. (5–8 mm). Both interlocked circuit breakers must ...

Page 45

Section 4—Wiring Diagrams Table 63: Figure 13: Function Auxiliary Contacts Remote Operation MX/SHT MN/UVR D1 D4 © 2004–2010 Schneider Electric All Rights Reserved PowerPact Connector Descriptions Function Description Open/Closed circuit breaker or switch position contacts Auxiliary Contacts ...

Page 46

PowerPact H- and J-Frame Circuit Breakers Section 4—Wiring Diagrams Standard Motor Operator Wiring (Factory Wiring Configuration) A circuit breaker may be configured for remote operations. Remotely operated circuit breakers are factory wired for the power supply to the motor ...

Page 47

Section 5—Dimensions H-Frame Dimensional Drawings Figure 16: 15–150 A Bus Bar H-Frame 2P HD/HG Circuit Breaker 6.40 [ 162,6 ] 5.66 [ 143,8 ] .74 [ 18,8 ] .68 [ 17,3 ] 1.38 [ 35,0 ] .44 [ 11,3 ] ...

Page 48

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Figure 17: 15–150 A Unit Mount H-Frame 2P HD/HG Circuit Breaker 6.40 [ 162,6 ] 5.66 [ 143,8 ] .74 [ 18,8 ] .69 1. 35,0 ] ...

Page 49

Figure 19: 15–150 A Lug-Lug H-Frame 3P Circuit Breaker 6.40 [ 162,6 ] 5.66 [ 143,8 ] (MOUNTING HOLE) .74 [ 18,8 ] 1.38 [ 35,0 ] 2.06 [ 52,4 ] .44 1.38 [ 11,3 ] 1.37 [ 35,0 ] ...

Page 50

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Figure 21: Motor Operator Detail (H-Frame) 6.40 [ 162,6 ] 5.66 [ 143,8 ] .74 [ 18,8 ] 1.38 [ 35,0 ] 2.06 [ 52,4 ] 1.38 .44 [ 35,0 ] ...

Page 51

J-Frame Dimensional Drawings Figure 23: 150–250 A Bus Bar J-Frame 3P Circuit Breaker 7.52 [ 191,0 ] 6.22 [ 158,0 ] 1.30 1. 35,0 ] 2.06 [ 52,4 ] 1.00 1. 35,0 ...

Page 52

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Figure 25: 150–250 A Rear Connected J-Frame 3P Circuit Breaker 8.00 [ 203,2 ] 6.46 [ 164,1 ] 1.54 [ 39,1 ] 2.06 [ 52,4 ] 2.04 [ 51,8 ] 2.84 ...

Page 53

Plug-In H- and J-Frame Dimensional Drawings Figure 28: 15–250 A H- and J-Frame Plug-In Base 3P Circuit Breaker Figure 29: 15–250 A H- and J-Frame Plug-In Circuit Breaker 3P Circuit Breaker © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact ...

Page 54

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Drawout H- and J-Frame Dimensional Drawings Figure 30: 15–250 A H and J-Frame Cradle 3P Circuit Breaker Figure 31: 15–250 A H- and J-Frame Drawout Circuit Breaker 3P Circuit Breaker 54 ...

Page 55

Mounting Dimensional Drawings Figure 32: H-Frame 2P (HD and HG) Circuit Breaker Figure 33: H and J-Frame 3P Circuit Breaker © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Dimensions: in. [mm] in. ...

Page 56

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions H- and J-Frame Door Cutout Dimensional Drawings Figure 34: H and J-Frame Circuit Breaker Toggle Handle Door Cutout Figure 35: H and J-Frame Circuit Breaker Toggle Handle With Escutcheon Door Cutout ...

Page 57

Figure 36: H and J-Frame Circuit Breaker Fixed Rotary Handle Cutout Figure 37: H and J-Frame Circuit Breaker Door Mounted Rotary Handle Cutout © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions in. ...

Page 58

PowerPact H- and J-Frame Circuit Breakers Section 5—Dimensions Figure 38: H and J-Frame Circuit Breaker Motor Operator Cutout 58 06/2010 in. Dimensions: [mm] © 2004–2010 Schneider Electric All Rights Reserved ...

Page 59

Section 6—Trip Curves Figure 39: 15-35 A — HD, HG, HJ and HL MULTIPLES OF RATED CURRENT 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 600 500 400 300 200 150 100 90 80 ...

Page 60

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 40: 40-60 A — HD, HG, HJ and HL MULTIPLES OF RATED CURRENT 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 600 500 ...

Page 61

Figure 41: 70-100 A — HD, HG, HJ, and HL MULTIPLES OF RATED CURRENT 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 600 500 400 300 MAXIMUM SINGLE-POLE TRIP TIMES AT 25°C BASED ON ...

Page 62

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 42: 110-150 A — HD, HG, HJ, and HL MULTIPLES OF RATED CURRENT 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 600 500 ...

Page 63

Figure 43: 150-250 A — JD, JG, JJ, and JL MULTIPLES OF RATED CURRENT 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 600 500 400 MAXIMUM SINGLE-POLE TRIP TIMES 300 AT 25°C BASED ON ...

Page 64

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 44: H-Frame 150 A (HD, HG, HJ, and HL) Curve No. 50-6 Let-Through I and 50-7 Peak Let-Through Current ...

Page 65

Figure 45: J-Frame 250 A (JD, JG, JJ, and JL) Curve No. 50-8 Let-Through I and 50-9 Peak Let-Through Current Available ...

Page 66

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 46: H- and J-Frame Motor Circuit Protector Š © 2006 Schneider Electric all rights reserved 66 06/2010 POWERPACT H/J FRAME MOTOR CIRCUIT PROTECTOR WITH MANUAL SETTINGS CHARACTERISTIC TRIP CURVE ...

Page 67

Figure 47: H- and J-Frame Motor Circuit Protector Š © 2006 Schneider Electric all rights reserved © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves POWERPACT H/J FRAME MOTOR CIRCUIT PROTECTOR WITH ...

Page 68

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 48: H-Frame Current-Limiting Circuit Breaker 68 06/2010 © 2004–2010 Schneider Electric All Rights Reserved ...

Page 69

Figure 49: H-Frame Current-Limiting Circuit Breaker © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves 69 06/2010 ...

Page 70

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 50: J-Frame Current -Limiting Circuit Breaker 70 06/2010 © 2004–2010 Schneider Electric All Rights Reserved ...

Page 71

Figure 51: J-Frame Current-Limiting Circuit Breaker © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves 71 06/2010 ...

Page 72

PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Figure 52: Ground Fault Module GFM150HD Trip Curve Pickup Levels ±10% Figure 53: Ground Fault Module GFM250JD Trip Curve Pickup Levels ±10% 72 06/2010 Current in Amperes Current in Amperes ...

Page 73

Figure 54: Earth Leakage Module Trip Curve © 2004–2010 Schneider Electric All Rights Reserved ® PowerPact H- and J-Frame Circuit Breakers Section 6—Trip Curves Catalog Number Circuit Breaker CB Amps ELM150HD PowerPact H-Frame 15–150 ELM250JD PowerPact J-Frame 150–250 Total clearing ...

Page 74

PowerPact H- and J-Frame Circuit Breakers Section 7—MCP Instantaneous Trip Points Section 7—MCP Instantaneous Trip Points Table 64: Motor Type FLA Dampening for motor in-rush (% FLA) Table 65: Motor Type FLA Dampening for motor in-rush (% FLA) 1 ...

Page 75

Table 66: Motor Type FLA Dampening for motor in-rush (% FLA) 1 ± nominal amperage shown above Table 67: Motor Type FLA Dampening for motor in-rush (% FLA) 1 ± nominal amperage shown above © 2004–2010 ...

Page 76

PowerPact H- and J-Frame Circuit Breakers Section 7—MCP Instantaneous Trip Points Table 68: Motor Type FLA Dampening for motor in-rush (% FLA) 1100–1300% 1100–1700% 1 ± nominal amperage shown above 2 2500 A maximum instantaneous trip point ...

Page 77

I NDEX A accessories auxiliary switches 35 locations of internal 34 maximum combinations of 34 motor operator accessory connections 34 accessory suffix codes 8 AIR See ampere interrupting rating altitude.See operating conditions ampere interrupting rating 5 automatic protection settings 21 ...

Page 78

PowerPact H- and J-Frame Circuit Breakers Index UL 489 re-rating altitude rotary operating handles 39 directly mounted door mounted 40 Rubber boot, Boot, rubber 44 S safety trip interlock shunt trip (MX) 35 special ratings specifications molded case switches ...

Page 79

... PowerPact H- and J-Frame Circuit Breakers HDL36110 ........................ 15 HGL26125C ..................... 15 HDL36110C ..................... 15 HGL26150 .......................15 HDL36110T ..................... 18 HGL26150C ..................... 15 HDL36125 ........................ 15 HGL36000S15 ................. 24 HDL36125C ..................... 15 HGL3600S15 ..................... 24 HDL36125T ..................... 18 HGL36015 .......................15 HDL36150 ........................ 15 HGL36015C ..................... 15 HDL36150C ..................... 15 HGL36015T ..................... 18 HDL36150T ..................... 18 HGL36020 .......................15 HGA26000S15( ) ............. 25 HGL36020C ..................... 15 HGA26015( ) .................... 17 HGL36020T ..................... 18 HGA26020( ) .................... 17 HGL36025 .......................15 HGA26025( ) .................... 17 HGL36025C ..................... 15 HGA26030( ) .................... 17 HGL36025T ..................... 18 HGA26035( ) .................... 17 HGL36030 .......................15 HGA26040( ) .................... 17 HGL36030C ..................... 15 HGA26045( ) .................... 17 HGL36030T ..................... 18 HGA26050( ) .................... 17 HGL36035 ...

Page 80

PowerPact H- and J-Frame Circuit Breakers HJL36080C ...................... 15 HLL26090 ........................ 15 HJL36080T ...................... 18 HLL26090C ...................... 15 HJL36090 ........................ 15 HLL26100 ........................ 15 HJL36090C ...................... 15 HLL26100C ...................... 15 HJL36090T ...................... 18 HLL26110 ........................ 15 HJL36100 ........................ 15 ...

Page 81

S29390 .............................. 8 S31540 .............................. 8 S29391 ............................ 36 S31541 ............................ 39 S29391 .............................. 8 S31541 .............................. 8 S29392 ............................ 36 S31542 ............................ 39 S29392 .............................. 8 S31542 .............................. 8 S29393 ............................ 36 S31543 ............................ 39 S29393 .............................. 8 S31543 ...

Page 82

...

Page 83

...

Page 84

... Schneider Electric USA, Inc. 3700 Sixth St. SW Cedar Rapids, IA 52404 USA 1-888-Square D 1-888-778-2733 www.schneider-electric.us 0611CT0401R © 2004–2010 Schneider Electric All Rights Reserved Replaces 0611CT0401R05/09 06/2010 ...

Related keywords